Plan Review Details - Permit 03121150
Plan Review Stops For Permit 03121150
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-03-01 Cont ID  
Sent By rmcdouga Date 2004-03-01 Time 09:54 Rev Time 2.00
Received By rmcdouga Date 2004-03-01 Time 09:54 Sent To  
Notes
2004-03-01 00:00:00PROVISO
  
 1) SURVEY LISTS AN INCORRECT FLOOD ZONE
 AND FLOOD MAP NUMBER. SUBMIT A REVISED
 SURVEY WITH CORRECTED INFORMATION.
  
 2) THE STRUCTURE IS LOCATED IN AN "AO"
 FLOOD ZONE AN ELEVATION CERTIFICATE WILL
 BE REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-29 Cont ID  
Sent By dpalmer Date 2004-02-19 Time 13:06 Rev Time 2.00
Received By rmcdouga Date 2004-01-28 Time 16:20 Sent To  
Notes
2004-01-28 00:00:00DENIED
  
 1) SUBMIT A COPY OF THE PAID RECEIPT FOR
 IMPACT FEES.
  
 2) STRUCTURE IS LOCATED IN AN "AO" FLOOD
 ZONE AN ELEVATION CERTIFICATE WILL BE
 REQUIRED BEFORE CO.
  
 3) SUBMIT A SIGNED AND SEALED COPY OF
 THE SOIL REPORT.
  
 4) SHEET A0.01 LISTS THE CONSTRUCTION AS
 TYPE V. BASED ON FBC TABLE 600, THE
 CONSTRUCTION IS TYPE VI. PLEASE CORRECT.
  
 5) NOTE 22 ON A0.01 REFERS TO FBC SECT.
 1816.1.7, WHICH IS FOR TERMITE BAITING
 SYSTEMS. PLEASE CLARIFY. NOTE: A SIGNED
 CONTRACT PAID IN FULL FOR FIVE YEARS
 FROM THE DATE OF C.O. IS REQUIRED BEFORE
 THE SLAB IS POURED.
  
 6) REVISE THE DRYWALL FASTENING NOTE ON
 A3.1. THE FASTENER SPACING FOR SCREWS IS
 NOT MORE THAN 12"OC FOR CEILINGS AND
 WALLS ON FRAMING 24"OC. SEE FBC 2504.4.1
 AND GA 216.
  
 7) REVISE THE ROOF SHEATHING FASTENER
 SPACING NOTE ON A1.02 TO CORRESPOND WITH
 THE NOTES ON A3.01 AND S4.
  
 8) REVISE DETAIL 2 ON A4.01 TO SHOW
 FIREBLOCKING WHERE THE WALL AND CEILING
 MEET. SEE FBC 2305.1.
  
 9) REVISE THE GLASS BLOCK DETAIL 10 ON
 A4.02 TO A ONE HOUR RATED ASSEMBLY. SEE
 UL R2556.
  
 10)SPECIFY THE LENGTH/EMBED DEPTH OF THE
 3/4" DIA. WEDGE ANCHOR BOLTS IN DETAIL 2
 ON S5 AND THE 5/8" DIA. W.A. BOLTS IN
 SECTIONS E-E AND F-F ON S5.
  
 11) SPECIFY THE ATTIC LIVE LOADS ON S2.
 FBC TABLE 1604.1 REQUIRES 30 PSF FOR
 ATTICS WITH STORAGE AND 10 PSF FOR
 ATTICS WITHOUT STORAGE.
  
 12) THE KEY PLAN AND INSTALLATION
 SCHEDULE FOR THE STORM PANELS DO NOT
 MATCH THE PLANS. CHECK THE NUMBER, SIZES
 AND LOCATIONS OF THE OPENINGS.
  
 13) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-02-19 Cont ID  
Sent By dpalmer Date 2004-02-19 Time 13:06 Rev Time 0.33
Received By dpalmer Date 2004-02-19 Time 13:06 Sent To B
Notes
2004-02-19 00:00:00REDLINED 2002 NEC FOR 210.12

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-12-24 Cont ID  
Sent By csiegber Date 2004-02-13 Time 11:23 Rev Time 0.33
Received By dpalmer Date 2003-12-24 Time 07:41 Sent To M
Notes
2003-12-24 00:00:00*************** UNSAT ***************
  
 1)NOTE: PLEASE SEE THAT PLANS STILL
 REFERENCE THE 1999 NEC AND ALL CODES
 ON PLANS ARE ALSO FROM 99 NEC.
 PLEASE CORRELATE WITH 2002 NEC WHICH
 WENT TO AFFECT 7/1/03.
  
 2)NOTE: PLEASE SEE 210.12/ ARC FAULT
 PROTECTION HAS CHANGED. PLEASE SEE 2002
 NEC.
  
 3)NOTE: PLEASE AHVE PLANS SIGNED AND
 DATED BY THE ENGINEER OF RECORD. PLANS
 MUST HAVE A SIGNATURE PER FS 471.025
 AND FAC 61G15-23.002. FBPE'S STATED
 INITIALS ARE NOT ACCEPATBLE AND SIGNAT-
 -URE SHOULD CORRELATE W/ LICENSE.
  
 PLEASE ADJUST PLANS.
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 11:23 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 11:23 Sent To E
Notes
2004-02-13 00:00:00TO DP DESK/RESUB/E REV TO MASTERED

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-29 Cont ID  
Sent By mmclean Date 2004-02-13 Time 11:23 Rev Time 0.00
Received By csiegber Date 2003-12-18 Time 14:59 Sent To  
Notes
2003-12-22 00:00:0012/18/03TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2004-01-28 Cont ID  
Sent By jleech Date 2004-01-03 Time 06:57 Rev Time 0.50
Received By hmoser Date 2004-01-14 Time 14:15 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-03 Cont ID  
Sent By jleech Date 2004-01-03 Time 06:57 Rev Time 0.25
Received By jleech Date 2004-01-03 Time 06:56 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-19 Cont ID  
Sent By alange Date 2003-12-18 Time 14:59 Rev Time 0.00
Received By mmclean Date 2003-12-19 Time 16:39 Sent To I
Notes
***NONE***