Plan Review Details - Permit 03121140
Plan Review Stops For Permit 03121140
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2004-01-26 Cont ID  
Sent By kstevens Date 2004-01-26 Time 10:51 Rev Time 0.75
Received By lsmith Date 2004-01-26 Time 11:29 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-01-23 Cont ID  
Sent By dpalmer Date 2004-01-23 Time 14:39 Rev Time 0.25
Received By dpalmer Date 2004-01-23 Time 14:39 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-01-06 Cont ID  
Sent By csiegber Date 2004-01-21 Time 14:36 Rev Time 0.25
Received By dpalmer Date 2004-01-06 Time 10:59 Sent To B
Notes
2004-01-06 00:00:00*********** PLEASE NOTE***********
  
 PLEASE SEE THAT ELECTRICAL IS OK,
 HOWEVER, IT IS ON THE SAME PAGE AS
 PLUMB AND PLUMB HAS COMMENTS FOR CODE
 COMPLIANCE.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 561-805-6717

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 14:35 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 14:35 Sent To E
Notes
2004-01-21 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-18 Cont ID  
Sent By mmclean Date 2004-01-21 Time 14:26 Rev Time 0.00
Received By alange Date 2003-12-18 Time 14:13 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-01-26 Cont ID  
Sent By kstevens Date 2004-01-26 Time 10:50 Rev Time 0.33
Received By kstevens Date 2004-01-26 Time 10:50 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2004-01-05 Cont ID  
Sent By dpalmer Date 2004-01-23 Time 14:39 Rev Time 0.50
Received By kstevens Date 2004-01-05 Time 09:35 Sent To E
Notes
2004-01-05 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 4) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-22 Cont ID  
Sent By alange Date 2003-12-18 Time 14:13 Rev Time 0.00
Received By mmclean Date 2003-12-22 Time 14:25 Sent To I
Notes
***NONE***