Plan Review Stops For Permit 03121040 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-03-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-03-13 |
Time |
05:06 |
Rev Time |
0.50 |
Received By |
shill |
Date |
2004-03-13 |
Time |
05:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2004-01-21 |
Time |
17:31 |
Rev Time |
3.00 |
Received By |
shill |
Date |
2004-01-21 |
Time |
17:31 |
Sent To |
|
|
Notes |
2004-01-21 00:00:00 | *****PROVISO/CORRECTIONS****** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | ADDRESS ALL BUILDING CORRECTIONS AT THIS | | TIME IF THE PLANS DO NOT PASS OTHER | | TRADES!!! | | | | COMMENTS ALSO APPLY TO 03121105, | | 03121071,03121087, 03121095, 03121058 | | | | 1.)THE NOTICE OF COMMENCEMENT IS | | EXPIRED FS713.13 (90 DAYS WITHOUT | | COMMENCING WORK). | | | | 2.)S-1, WATERSTOP TO BE 1 1/2" CITY OF | | WEST PALM BEACH AMENDMENTS TO THE FBC | | 2111.1.9.CHECK ALL DETAILS. | | | | 3.)BOTTOM CHORD LIVE LOAD IS REQUIRED | | TO BE 10, 30 IN ATTICS WITH STORAGE, | | FBC TABLE 1604.1., (SHEET S8, #9). | | | | THE FOLLOWING COMMENTS MUST BE | | ADDRESSED BEFORE THE PERMIT CAN BE | | ISSUED - NO PROVISO | | | | 4.)MANY PRODUCT APPROVALS WERE | | SUBMITTED FOR ITEMS WHICH DO NOT APPEAR | | ON THE PLAN.PRODUCT APPROVALS FOR | | FIXED GLASS AND SINGLE HUNG WINDOWS | | WERE SUBMITTED, BUT NOT FOR HORIZONTAL | | SLIDERS (THE ONLY WINDOW SHOWN ON THE | | PLAN).SUBMIT ONLY PRODUCT APPROVALS | | FOR DOORS, WINDOWS, AND ROOF WHICH | | APPEAR ON THE PLAN. | | | | PRODUCT APPROVALS NOT SUBMITTED BEFORE | | ISSUANCE WILL REQUIRE SEPARATE PERMITS | | WITH ADDITIONAL FEES FOR THOSE ITEMS. | | | | 5.)FLORIDA STATEWIDE PRODUCT APPROVALS | | OR SITE SPECIFIC REQUIRED, SEE DCA | | WEBSITE AT WWW.FLORIDABUILDING.ORG. | | RULE 9B-72 EFFECTIVE OCTOBER 1, 2003. | | | | 6.)SUBMIT A HURRICANE SHUTTER | | INSTALLATION SCHEDULE, SEE ATTACHED.IF | | THIS IS NOT SUBMITTED BEFORE TIME OF | | PERMIT ISSUANCE A SEPARATE PERMIT FOR | | THIS ITEM WILL BE REQUIRED. | | | | 7.)PROVIDE AREA CALCULATIONS FOR | | EACH UNIT TYPE - A/C SPACE, NON A/C | | SPACE, TOTAL. | | | | 8.)PROVIDE A SOILS INVESTIGATION | | REPORT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
16:53 |
Rev Time |
1.50 |
Received By |
shill |
Date |
2003-12-29 |
Time |
12:57 |
Sent To |
|
|
Notes |
2003-12-29 00:00:00 | *****CORRECTIONS****** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEVERAL SHEETS DO NOT MATCH THE | | MASTER PERMIT #03030456: | | | | A1.01, A1.02, A3.03, A5.01, E101, M2,S9 | | | | 2.)NOTE THAT FBC 2003 AMENDMENTS | | AND NEC2002 CAME INTO EFFECT 7/1/03 | | (AFTER THE MASTER WAS REVIEWED).PLANS | | WILL BE REVIEWED FOR ANY CHANGES WHICH | | MAY BE REQUIRED BY THE CODE CHANGES | | AND A PERMIT WILL BE ISSUED WITH A | | PROVISO THAT ANY CHANGES REQUIRED, IF | | ANY, BE ADDRESSED WITH A REVISION. | | | | 3.)SAME COMMENTS APPLY TO 03121105, | | 03121071, 03121087, 03121095, 03121058. | | | | 4.)SUBMIT PRODUCT APPROVALS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-03-05 |
Time |
14:33 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-03-05 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-03-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-03-01 |
Time |
06:25 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-03-01 |
Time |
06:25 |
Sent To |
|
|
Notes |
2004-03-01 00:00:00 | *************** UNSAT *********** | | | | 1)NOTE: PLEASE SEE COMMENTS FROM FIRST | | REVIEW. | | | | | | 2)NOTE: PLEASE PROVIDE ADDRESS IN TITLE | | BLOCK/LOT #MIN FOR SITE. AS REQ'D UNDER | | FAC 61G1-16.004. | | | | 3)NOTE: PLEASE HAVE ALL CIRCUITING | | CONFORM TO THE 2002 NEC FOR ARC FAULT | | PROTECTION. 210.12CIRCUITS#'S 13,15 | | | | 4))NOTE: PLEASE SEE NFPA-72 8-1.4.1.6.2 | | ALL SD'S ARE REQ'D TO BE WIRED INLINE, | | HOWEVER, SD'D ARE NOW SHOWN ON SEPARATE | | CIRCUITS? | | | | 5)NOTE: PLEASE REMOVE ALL OLD/VOIDED | | SHEETS AND INSERT NEW ONLY. | | | | PLANS/PERMIT APPLICATION/COMPUTER WILL | | NO LONGER REFERENCE MASTER SINCE THE | | CODE CHANGED 7/1/03 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-29 |
Time |
14:51 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-01-29 |
Time |
14:51 |
Sent To |
|
|
Notes |
2004-01-29 00:00:00 | *************** UNSAT *********** | | | | 1)NOTE: PLEASE PROVIDE ADDRESS ON PLANS | | AS REQ'D UNDER FAC 61G1-16.004 | | | | 2)NOTE: PLEASE SEE NOTES ON PLANS | | REFERENCE THE 1999 NEC AND THE SFBC | | WHICH NEITHER ONE IS ANY LONGER IN | | EFFECT. PLEASE ADJUST PLANS AND ALL | | CODE #'S TO CORRELATE TO 2002 NEC. | | | | 3)NOTE: PLEASE PROVIDE CIRCUITING'S ON | | PLANS AND PANEL SCHEDULE IN ORDER TO | | PROVIDE REQ'D ARC FAULT PROTECTION PER | | THE 2002 NEC. PLANS NOW SHOW WHAT IS | | REQ'D UNDER THE 1999 NEC. | | | | 4)NOTE: PLEASE SEE CODE REFERENCED FOR | | GROUNDING ELECTRODE SYSTEM. CODES ARE | | FOR 1999 NEC. PLEASE SEE 2002 | | | | 5)NOTE: PLEASE SEE NOTES FROM OTHER | | REVIEWERS. | | | | PLEASE REMOVE ALL OLD/ VOIDED SHEETS | | AND INSERT NEW SHEETS INTO TWO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-02-20 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-02-20 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-02-20 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2004-01-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-01-29 |
Time |
07:58 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-01-29 |
Time |
07:58 |
Sent To |
|
|
Notes |
2004-01-29 00:00:00 | 1) WET FIRE HYDRANTS ARE REQUIRED | | PRIOR TO, DURING AND AFTER CONSTRUCTION. | | | | 2) BUILDING ADDRESSES ARE REQUIRED. | | | | 3) PORTABLE FIRE EXTINGUISHERS ARE | | REQUIRED. | | | | 4) EGRESS WINDOWS SHALL COMPLY WITH | | BUILDING AND FIRE CODE REQUIREMENTS. | | | | THESE COMMENTS ALSO APPLY TO | | PERMIT NUMBERS 03121058, 03121058, | | 031212095, 03121087, 03121071, 03121105 | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-05-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-17 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-17 |
Time |
09:11 |
Sent To |
P |
|
Notes |
2004-05-17 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-22 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-22 |
Time |
09:43 |
Sent To |
|
|
Notes |
2004-01-22 00:00:00 | TO COMM BD#50 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-20 |
Time |
16:53 |
Sent To |
B |
|
Notes |
2004-01-20 00:00:00 | TO SH DESK/RESUB/MASTERED |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-02-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-05-05 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-18 |
Time |
13:23 |
Sent To |
|
|
Notes |
2003-12-22 00:00:00 | 12/18/03TO Z | | TO HP DESK/MASTERED |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-03-03 |
Time |
06:37 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-03-03 |
Time |
06:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2004-02-02 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-02-02 |
Time |
12:33 |
Rev Time |
1.00 |
Received By |
pkrauss |
Date |
2004-02-02 |
Time |
11:46 |
Sent To |
|
|
Notes |
2004-02-02 00:00:00 | DENIED | | COMMENTS PERTAIN TO THE FOLLOWING PERMIT | | NUMBERS:03121040, 03121058, 03121095, | | 03121087, 03121071, 03121105 | | | | MODEL A, B, & C | | 1.PROVIDE OUTSIDE AIR CALCULATIONS PER | | 2001 FBC(M) 402.2 OR 403.3. | | | | 2.RETURN AIR TRANSFER GRILLE FROM THE | | MASTER BEDROOM IS NOT SIZED PROPERLY. | | REFERENCE 2001 FBC(M) 601.4 EXCEPTION #2 | | AND 3. GRILLES SHALL HAVE 50 SQ INCHES | | TO 100 CFM OF SUPPLY AIR. FOR PROPER | | SIZING FOR THE RETURN TRANSFER GRILLE TO | | THE MASTER BEDROOM, ALL SUPPLY AIR TO | | THE SUITE IS TO BE INCLUDED IN THE | | CALCULATION.PLEASE REVISE. | | | | 3.AUXILIARY DRAIN PAN REQUIRED PER | | 2001 FBC(M) 307.2.3. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-06-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2004-06-02 |
Time |
19:17 |
Rev Time |
0.15 |
Received By |
jleech |
Date |
2004-06-02 |
Time |
19:17 |
Sent To |
|
|
Notes |
2004-06-02 00:00:00 | REV. H2O PIPE FROM COPPER TO CPVC |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-03-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-17 |
Time |
09:12 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-03-03 |
Time |
11:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2004-01-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-31 |
Time |
11:43 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-01-31 |
Time |
11:43 |
Sent To |
|
|
Notes |
2004-01-31 00:00:00 | DENIED | | REFERENCE: FLORIDA ADMIN. CODE | | FLORIDA STATUTES | | | | A PROFESSIONAL ENGINEER SHALL SIGN HIS | | NAME AND AFFIX HIS SEAL TO ALL PLANS, | | SPECIFICATIONS, REPORTS AND FINAL BID | | DOCUMENTS PROVIDED TO THE OWNER OR THE | | OWNER'S REPRESENTATIVE, OR OTHER DOCU- | | MENTS PREPARED OR ISSUED BY SAID REGIS- | | TRANT AND BEING FILED FOR PUBLIC RECORD. | | THE DATE THAT THE SIGNATURE AND SEAL IS | | AFFIXED AS PROVIDED HEREIN SHALL BE EN- | | TERED ON SAID PLANS, SPECIFICATIONS, RE- | | PORTS, OR OTHER DOCUMENTS IMMEDIATELY | | UNDER THE SIGNATURE OF THE PROFESSIONAL | | ENGINEER, FAC 61G15-23.002(1) | | | | EACH SHEET OF PLANS AND PRINTS WHICH | | MUST BE SEALED UNDER THE PROVISIONS OF | | CHAPTER 471 SHALL BE SEALED, SIGNED AND | | DATED BY THE PROFESSIONAL ENGINEER IN | | RESPONSIBLE CHARGE. FAC 61G15-23.002(2) | | | | PER FBPE'S RULING INITIALS ARE NOT | | ACCEPTABLE. SUBMIT A SAMPLE OF YOUR | | SIGNATURE WITH COPY OF LICENSE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-12-19 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-12-18 |
Time |
13:24 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-12-19 |
Time |
16:33 |
Sent To |
I |
|
Notes |
|
|