Plan Review Stops For Permit 03120826 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2004-05-14 |
Time |
08:51 |
Rev Time |
1.22 |
Received By |
jwitmer |
Date |
2004-05-14 |
Time |
08:51 |
Sent To |
|
|
Notes |
2004-05-14 00:00:00 | BUILDING PROVISO: | | 1204.2 SURROUNDING MATERIALS; | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | ROOMS SHALL BE LINED WITH NONABSORBANT | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | FLOOR. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-02-23 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2004-02-13 |
Time |
15:48 |
Rev Time |
0.75 |
Received By |
jwitmer |
Date |
2004-02-13 |
Time |
15:48 |
Sent To |
|
|
Notes |
2004-02-23 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03120826 | | ADD: 2505 BROADWAY | | CONT: BRAVALOU VIDAL PLUMBING | | TEL: (561)310-3973 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) WHAT TYPE OF USE (OCCUPANCY) WAS THIS | | BUILDING USED FOR LAST? MAY REQUIRE | | COUNTY IMPACT FEES? SUBMIT TO PALM BEACH | | COUNTY BUILDING DEPARTMENT FOR REVIEW | | FOR IMPACT FEES. | | | | 2)INDICATE FRONT ENTRY, ACCESSIBLE | | FRONT ENTRY NO STAIRS. | | | | 3)1204.2 SURROUNDING MATERIALS; | | THE WALLS & FLOORS OF ALL PUBLIC REST- | | ROOMS SHALL BE LINED WITH NONABSORBANT | | MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE | | FLOOR. | | | | 1203.4.2 EVERY TOLIET ROOM SHALL | | HAVE WINDOWS AS SPECIFIED FOR HABITABLE | | ROOMS PROVIDING IN NO CASE LESS THAN 3 | | SQ FT OPEN SPACE, OR HAVE APPROVED EQUIV | | ALENT VENTILATION. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | 2004-02-19 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03120826 | | ADD: 2505 BROADWAY | | CONT: BRAVLOU VIDAL PLUMBING | | TEL: (561)310-3973 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-05-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-05-12 |
Time |
14:37 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-05-12 |
Time |
13:45 |
Sent To |
|
|
Notes |
2004-05-12 00:00:00 | PLANS SHOW ALL ELECTRICAL EXISTING | | TO REMAIN. | | ANY NEW WORK, REQ'D ELECTRICAL PERMIT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-07 |
Time |
15:33 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-02-24 |
Time |
06:12 |
Sent To |
|
|
Notes |
2004-02-24 00:00:00 | *************** UNSAT ************* | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH A SUBMITTED | | PANEL SCHEDULE. | | | | 2)NOTE: PLEASE SEE 700.12E FOR CIRCUIT- | | -ING OF EM/EXT LTS. | | | | 3)NOTE: PLANS MUST BE SUBMITTED FOR | | PERMIT FOR CHANGE OF OCCUPANCY. | | PER 104.1.1 | | | | 4)NOTE: PLEASE SEE 210.62 FOR SHOW | | WINDOW RECEPTS REQ'D. LOADS TO BE SHOWN | | PER 220.12 | | | | 5)NOTE: PLEASE SEE 600.5 FOR MIN SIGN | | CIRCUIT. | | | | 6)NOTE: PLEASE SHOW LOAD CALCS AND SIZE | | OF SERVICE. NEW / EXISTING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-05-14 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-05-14 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-05-14 |
Time |
09:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2004-02-13 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-02-13 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-02-13 |
Time |
14:14 |
Sent To |
|
|
Notes |
2004-02-13 00:00:00 | 1) ENSURE THAT EMERGENCY LIGHTS ARE | | PRESENT. | | | | 2) ENSURE THAT THE BUILDING ADDRESS | | IS PRESENT OF THE BUILDING. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-11 |
Time |
10:27 |
Sent To |
|
|
Notes |
2004-05-11 00:00:00 | TO COMM BD#10 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-05-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-05-10 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-10 |
Time |
07:53 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-02-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-12 |
Time |
10:12 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-12 |
Time |
10:12 |
Sent To |
|
|
Notes |
2004-02-12 00:00:00 | TO COMM BD#22 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-02-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-02 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-15 |
Time |
14:16 |
Sent To |
P |
|
Notes |
2004-02-02 00:00:00 | TO KS BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
10:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-16 |
Time |
10:27 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-05-22 |
Time |
06:40 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-05-22 |
Time |
06:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-02-24 |
Time |
10:28 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2004-02-24 |
Time |
10:28 |
Sent To |
|
|
Notes |
2004-02-24 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | | | 1) FROM PREVIOUS REVIEW:2 COMMENTS | | (3) TOILET ROOM SHALL BE ACCESSIBLE PER | | 11-4.1.2(6). SUBMIT DETAILS FOR FIXTURES | | PER 11-4.16 WATER CLOSET, 11-4.19 LAV., | | AND 11-4.22 TOILET ROOM. SHOW CLEAR | | FLOOR SPACE FOR FIXTURES, GRAB BAR | | HEIGHT, LAV HEIGHT AND CLEARANCES, | | TOILET HEIGHT, EXPOSED PIPES AND SURFAC- | | ES FOR LAV. ECT. INDICATE INTERIOR | | MEASUREMENTS FOR TOILET ROOM. | | (8) PER TABLE 403.1 A DRINKING FOUNTAIN | | IS REQUIRED. (ALSO SEE SECTION 410.1) | | **********NEW COMMENTS********** | | 1B) SHT 5 SANITARY RISER DIAGRAM: THE | | THREE COMPARTMENT SINK SHALL DRAIN INTO | | THE FLOOR SINK. IT IS TIED INTO THE SAN- | | ITARY BRANCH LINE DIRECTLY. A SAMPLE | | POINT IS REQUIRED PRIOR TO THE TOILET | | ROOM ON THE SANITARY RISER DIAGRAM. | | 2B) SUBMIT A WATER RISER DIAGRAM REQUIR- | | ED PER SECTION 104.3.1.1. | | 3B) INFORMATIONAL: DEPT OF AGRICULTURE | | & CONSUMER SERVICES SHALL BE REQUIRED | | TO BE NOTIFIED PRIOR TO OPENING. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-02-24 |
Time |
10:11 |
Rev Time |
1.50 |
Received By |
kstevens |
Date |
2003-12-29 |
Time |
15:47 |
Sent To |
|
|
Notes |
2003-12-29 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | | | 1) PERMIT FOR PLUMBING CAN NOT BE ISSUED | | PRIOR TO CLAIRFICATION OF PREVIOUS OCC- | | UPANCY FOR SPACE. MORE COMMENTS MAY NEED | | TO BE ADDRESSED ACCORDING TO RESPONSE. | | OTHER PLAN REVIEWS MAY BE REQUIRED BY | | BLDG., FIRE, ELECT., & MECH. 104.2.1.2 | | 2) FIRE DEPT PLAN REVIEW REQUIRED FOR | | NEW RESTURANT. 104.3.1.1(7). | | 3) TOILET ROOM SHALL BE ACCESSIBLE PER | | 11-4.1.2(6). SUBMIT DETAIL FOR FIXTURES | | PER 11-4.16 WATER CLOSET, 11-4.19 LAV., | | AND 11-4.22 TOILET ROOM. SHOW CLEAR | | FLOOR SPACE, TURNING AREA, AND ALL SUB- | | SECTIONS OF ABOVE SECTIONS FOR COMPLIAN- | | CE. INDICATE INTERIOR MEASUREMENTS FOR | | TOILET ROOM. | | 4) ROUTE PLANS TO THE DEPT. OF BUSINESS | | REGULATION, HOTEL AND BUSINESS DIVISION. | | 101.4.7 | | 5) CONTACT RODNEY COMPO, ENVIRONMENTAL | | COMPLIANCE FOR SIZE OF GREASE INTERCEPT- | | OR. WASTE ORD. 2938-96. (561) 837-4074. | | 6) SHT 2 OF 5 GREASE TRAP NOT ALLOWED | | UNDER SINK. (SEE COMMENT #5) | | 7) HAND SINK NOT SHOWN ON FLOOR PLAN. | | PLEASE SHOW HAND SINK. 104.2.1 | | 8) PER TABLE 403.1 A DRINKING FOUNTAIN & | | A SERVICE SINK ARE REQUIRED. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2004-05-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-05-10 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-05-10 |
Time |
13:37 |
Sent To |
I |
|
Notes |
2004-05-10 00:00:00 | NO CONVIENCE STORE OR ALCOHOL ALLOWED | | IN NORTHWOOD MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2004-02-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-10 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-02-24 |
Time |
10:10 |
Sent To |
P |
|
Notes |
2004-02-24 00:00:00 | DENIED, NEED TO PROVIDE MORE INFORMATION | | AS TO WHAT TYPE OF BUSINESS AT LOCATION |
|
|