Plan Review Details - Permit 03120826
Plan Review Stops For Permit 03120826
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-05-14 Cont ID  
Sent By jwitmer Date 2004-05-14 Time 08:51 Rev Time 1.22
Received By jwitmer Date 2004-05-14 Time 08:51 Sent To  
Notes
2004-05-14 00:00:00BUILDING PROVISO:
 1204.2 SURROUNDING MATERIALS;
 THE WALLS & FLOORS OF ALL PUBLIC REST-
 ROOMS SHALL BE LINED WITH NONABSORBANT
 MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE
 FLOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-02-23 Cont ID  
Sent By spalmer Date 2004-02-13 Time 15:48 Rev Time 0.75
Received By jwitmer Date 2004-02-13 Time 15:48 Sent To  
Notes
2004-02-23 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03120826
 ADD: 2505 BROADWAY
 CONT: BRAVALOU VIDAL PLUMBING
 TEL: (561)310-3973
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1) WHAT TYPE OF USE (OCCUPANCY) WAS THIS
 BUILDING USED FOR LAST? MAY REQUIRE
 COUNTY IMPACT FEES? SUBMIT TO PALM BEACH
 COUNTY BUILDING DEPARTMENT FOR REVIEW
 FOR IMPACT FEES.
  
 2)INDICATE FRONT ENTRY, ACCESSIBLE
 FRONT ENTRY NO STAIRS.
  
 3)1204.2 SURROUNDING MATERIALS;
 THE WALLS & FLOORS OF ALL PUBLIC REST-
 ROOMS SHALL BE LINED WITH NONABSORBANT
 MATERIALS TO A HEIGTH OF 4'-0" ABOVE THE
 FLOOR.
  
 1203.4.2 EVERY TOLIET ROOM SHALL
 HAVE WINDOWS AS SPECIFIED FOR HABITABLE
 ROOMS PROVIDING IN NO CASE LESS THAN 3
 SQ FT OPEN SPACE, OR HAVE APPROVED EQUIV
 ALENT VENTILATION.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
2004-02-19 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03120826
 ADD: 2505 BROADWAY
 CONT: BRAVLOU VIDAL PLUMBING
 TEL: (561)310-3973
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 1ST REVIEW
 ACTION: DENIED
  
 1)

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-05-12 Cont ID  
Sent By dpalmer Date 2004-05-12 Time 14:37 Rev Time 0.33
Received By dpalmer Date 2004-05-12 Time 13:45 Sent To  
Notes
2004-05-12 00:00:00PLANS SHOW ALL ELECTRICAL EXISTING
 TO REMAIN.
 ANY NEW WORK, REQ'D ELECTRICAL PERMIT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2004-02-24 Cont ID  
Sent By csiegber Date 2004-05-07 Time 15:33 Rev Time 0.33
Received By dpalmer Date 2004-02-24 Time 06:12 Sent To  
Notes
2004-02-24 00:00:00*************** UNSAT *************
  
 1)NOTE: PLEASE SHOW ALL CIRCUITING ON
 PLANS AND CORRELATE WITH A SUBMITTED
 PANEL SCHEDULE.
  
 2)NOTE: PLEASE SEE 700.12E FOR CIRCUIT-
 -ING OF EM/EXT LTS.
  
 3)NOTE: PLANS MUST BE SUBMITTED FOR
 PERMIT FOR CHANGE OF OCCUPANCY.
 PER 104.1.1
  
 4)NOTE: PLEASE SEE 210.62 FOR SHOW
 WINDOW RECEPTS REQ'D. LOADS TO BE SHOWN
 PER 220.12
  
 5)NOTE: PLEASE SEE 600.5 FOR MIN SIGN
 CIRCUIT.
  
 6)NOTE: PLEASE SHOW LOAD CALCS AND SIZE
 OF SERVICE. NEW / EXISTING.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2004-05-14 Cont ID  
Sent By mcarsill Date 2004-05-14 Time 09:45 Rev Time 0.00
Received By mcarsill Date 2004-05-14 Time 09:45 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2004-02-13 Cont ID  
Sent By mcarsill Date 2004-02-13 Time 14:14 Rev Time 0.00
Received By mcarsill Date 2004-02-13 Time 14:14 Sent To  
Notes
2004-02-13 00:00:001) ENSURE THAT EMERGENCY LIGHTS ARE
 PRESENT.
  
 2) ENSURE THAT THE BUILDING ADDRESS
 IS PRESENT OF THE BUILDING.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-05-11 Cont ID  
Sent By csiegber Date 2004-05-11 Time 10:27 Rev Time 0.00
Received By csiegber Date 2004-05-11 Time 10:27 Sent To  
Notes
2004-05-11 00:00:00TO COMM BD#10

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-10 Cont ID  
Sent By mmclean Date 2004-05-10 Time 13:38 Rev Time 0.00
Received By csiegber Date 2004-05-10 Time 07:53 Sent To Z
Notes
2004-05-07 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-02-12 Cont ID  
Sent By csiegber Date 2004-02-12 Time 10:12 Rev Time 0.00
Received By csiegber Date 2004-02-12 Time 10:12 Sent To  
Notes
2004-02-12 00:00:00TO COMM BD#22

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-02-02 Cont ID  
Sent By csiegber Date 2004-02-02 Time 14:16 Rev Time 0.00
Received By csiegber Date 2003-12-15 Time 14:16 Sent To P
Notes
2004-02-02 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-16 Cont ID  
Sent By csiegber Date 2003-12-16 Time 10:27 Rev Time 0.00
Received By csiegber Date 2003-12-16 Time 10:27 Sent To P
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-05-25 Cont ID  
Sent By kstevens Date 2004-05-22 Time 06:40 Rev Time 1.00
Received By kstevens Date 2004-05-22 Time 06:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2004-02-24 Cont ID  
Sent By kstevens Date 2004-02-24 Time 10:28 Rev Time 1.50
Received By kstevens Date 2004-02-24 Time 10:28 Sent To  
Notes
2004-02-24 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) FROM PREVIOUS REVIEW:2 COMMENTS
 (3) TOILET ROOM SHALL BE ACCESSIBLE PER
 11-4.1.2(6). SUBMIT DETAILS FOR FIXTURES
 PER 11-4.16 WATER CLOSET, 11-4.19 LAV.,
 AND 11-4.22 TOILET ROOM. SHOW CLEAR
 FLOOR SPACE FOR FIXTURES, GRAB BAR
 HEIGHT, LAV HEIGHT AND CLEARANCES,
 TOILET HEIGHT, EXPOSED PIPES AND SURFAC-
 ES FOR LAV. ECT. INDICATE INTERIOR
 MEASUREMENTS FOR TOILET ROOM.
 (8) PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. (ALSO SEE SECTION 410.1)
 **********NEW COMMENTS**********
 1B) SHT 5 SANITARY RISER DIAGRAM: THE
 THREE COMPARTMENT SINK SHALL DRAIN INTO
 THE FLOOR SINK. IT IS TIED INTO THE SAN-
 ITARY BRANCH LINE DIRECTLY. A SAMPLE
 POINT IS REQUIRED PRIOR TO THE TOILET
 ROOM ON THE SANITARY RISER DIAGRAM.
 2B) SUBMIT A WATER RISER DIAGRAM REQUIR-
 ED PER SECTION 104.3.1.1.
 3B) INFORMATIONAL: DEPT OF AGRICULTURE
 & CONSUMER SERVICES SHALL BE REQUIRED
 TO BE NOTIFIED PRIOR TO OPENING.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-12-30 Cont ID  
Sent By mmclean Date 2004-02-24 Time 10:11 Rev Time 1.50
Received By kstevens Date 2003-12-29 Time 15:47 Sent To  
Notes
2003-12-29 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) PERMIT FOR PLUMBING CAN NOT BE ISSUED
 PRIOR TO CLAIRFICATION OF PREVIOUS OCC-
 UPANCY FOR SPACE. MORE COMMENTS MAY NEED
 TO BE ADDRESSED ACCORDING TO RESPONSE.
 OTHER PLAN REVIEWS MAY BE REQUIRED BY
 BLDG., FIRE, ELECT., & MECH. 104.2.1.2
 2) FIRE DEPT PLAN REVIEW REQUIRED FOR
 NEW RESTURANT. 104.3.1.1(7).
 3) TOILET ROOM SHALL BE ACCESSIBLE PER
 11-4.1.2(6). SUBMIT DETAIL FOR FIXTURES
 PER 11-4.16 WATER CLOSET, 11-4.19 LAV.,
 AND 11-4.22 TOILET ROOM. SHOW CLEAR
 FLOOR SPACE, TURNING AREA, AND ALL SUB-
 SECTIONS OF ABOVE SECTIONS FOR COMPLIAN-
 CE. INDICATE INTERIOR MEASUREMENTS FOR
 TOILET ROOM.
 4) ROUTE PLANS TO THE DEPT. OF BUSINESS
 REGULATION, HOTEL AND BUSINESS DIVISION.
 101.4.7
 5) CONTACT RODNEY COMPO, ENVIRONMENTAL
 COMPLIANCE FOR SIZE OF GREASE INTERCEPT-
 OR. WASTE ORD. 2938-96. (561) 837-4074.
 6) SHT 2 OF 5 GREASE TRAP NOT ALLOWED
 UNDER SINK. (SEE COMMENT #5)
 7) HAND SINK NOT SHOWN ON FLOOR PLAN.
 PLEASE SHOW HAND SINK. 104.2.1
 8) PER TABLE 403.1 A DRINKING FOUNTAIN &
 A SERVICE SINK ARE REQUIRED.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2004-05-10 Cont ID  
Sent By mmclean Date 2004-05-10 Time 13:37 Rev Time 0.00
Received By mmclean Date 2004-05-10 Time 13:37 Sent To I
Notes
2004-05-10 00:00:00NO CONVIENCE STORE OR ALCOHOL ALLOWED
 IN NORTHWOOD MM

Review Stop Z ZONING
Rev No 1 Status F Date 2004-02-24 Cont ID  
Sent By csiegber Date 2004-05-10 Time 07:53 Rev Time 0.00
Received By mmclean Date 2004-02-24 Time 10:10 Sent To P
Notes
2004-02-24 00:00:00DENIED, NEED TO PROVIDE MORE INFORMATION
 AS TO WHAT TYPE OF BUSINESS AT LOCATION