Plan Review Details - Permit 03120481
Plan Review Stops For Permit 03120481
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-28 Cont ID  
Sent By lsmith Date 2004-01-28 Time 15:00 Rev Time 2.00
Received By lsmith Date 2004-01-28 Time 15:00 Sent To  
Notes
2004-01-28 00:00:00PROOVISO
  
 1. STORM PANELS REQUIRE A SEPARATE
 PERMIT WITH INSTALLATION SCHEDULE.
 2. SUBMIT THE FLORIDA PRODUCT APPROVALS
 FOR THE TRUSS ANCHORS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2004-01-05 Cont ID  
Sent By pkrauss Date 2004-01-28 Time 10:45 Rev Time 0.00
Received By lsmith Date 2004-01-05 Time 15:29 Sent To  
Notes
2004-01-05 00:00:00BUILDING PLAN REVIEW: FAILED
  
 1. PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1,
 2003 ARE REQUIRED TO COMPLY WITH THE
 FLORIDA PRODUCT APPROVAL SYSTEM. FOR
 INFORMATION PLEASE SEE THE STATE
 WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 2. A SEPARATE PERMIT IS REQUIRED FOR
 THE STORM PANELS WITH SCHEDULE FOR
 OPENINGS & ANCHORING DETAIL.
  
 3. SEE NOTES FROM MECHANICAL &
 ELECTRICAL REVIEWS.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-05-05 Cont ID  
Sent By jleahy Date 2004-05-05 Time 10:32 Rev Time 0.15
Received By jleahy Date 2004-05-05 Time 10:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-01-26 Cont ID  
Sent By csiegber Date 2004-05-03 Time 13:46 Rev Time 0.33
Received By dpalmer Date 2004-01-26 Time 16:54 Sent To M
Notes
2004-01-26 00:00:00PLANS STILL REFERENCE ARC FAULT PROTECT-
 ION FOR RECEPTS.
 PLEASE SEE 2002 NEC ALL OUTLETS/ LIGHTS
 SD'S ETC.
 REDLINED ON PLANS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-12-23 Cont ID  
Sent By csiegber Date 2004-01-20 Time 16:43 Rev Time 0.33
Received By dpalmer Date 2003-12-23 Time 06:33 Sent To M
Notes
2003-12-23 00:00:00*********** UNSAT *****************
  
 1)NOTE; PLEASE MOVE SD SHOWN IN MASTER
 BEDROOM HALL INTO BEDROOM. NFPA-72, LS
 101 ETC. 8-1.4
  
 2)NOTE: PLEASE SEE PANEL SCHEDULE SHOWS
 PANEL AS 225A AND RISER SHOWS 200A.
  
 3)NOTE: PLEASE SEE NOTE FOR 210.12.
 WE ARE NOW UNDER THE 2002 NEC AND HAVE
 BEEN SINCE 7/1/03.REQUIREMENT HAS
 CHANGED.
  
 4)NOTE: PLEASE PROVIDE ROOM DESIGNATION
 ON PLANS.
  
 5)NOTE: PLEASE SEE THAT NOTES ARE STILL
 REFERENCING THE 1999 NEC.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
 PLEASE NOTE, IF PERMIT IS NOT ISSUED
 BY JAN 10TH, NOC WILL EXPIRE PER FS
 713. WORK MUST COMMENCE W/IN 90 DAYS
 OF RECORDING NOC.
 DATE ON NOC IS 10/10/03

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-03 Time 13:50 Rev Time 0.00
Received By csiegber Date 2004-05-03 Time 13:50 Sent To M
Notes
2004-05-03 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-03 Time 13:46 Rev Time 0.00
Received By csiegber Date 2004-05-03 Time 13:46 Sent To E
Notes
2004-05-03 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2004-01-20 Cont ID  
Sent By csiegber Date 2004-01-20 Time 16:43 Rev Time 0.00
Received By csiegber Date 2004-01-20 Time 16:43 Sent To E
Notes
2004-01-20 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2004-01-05 Cont ID  
Sent By mmclean Date 2003-12-09 Time 12:02 Rev Time 0.00
Received By csiegber Date 2003-12-09 Time 10:17 Sent To  
Notes
2003-12-09 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-05-07 Cont ID  
Sent By pkrauss Date 2004-05-07 Time 14:00 Rev Time 0.30
Received By pkrauss Date 2004-05-07 Time 14:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-28 Cont ID  
Sent By csiegber Date 2004-05-03 Time 13:50 Rev Time 0.35
Received By pkrauss Date 2004-01-28 Time 09:41 Sent To B
Notes
2004-01-28 00:00:00PROVISO:
 RETURN AIR IS NOT SIZED PROPERLY FOR THE
 MASTER BEDROOM OR THE OTHER BEDROOMS.
 PER 2001 FBC(M) 601.4 EXCEPTION #1 & 4.
 PLEASE SEE THE ATTACHED SCHEDULE FOR
 PROPER SIZING.
  
 PROVIDE REVSION FOR CHANGES PROIR TO
 INSPECTION.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-12-30 Cont ID  
Sent By dpalmer Date 2004-01-26 Time 16:54 Rev Time 0.50
Received By hmoser Date 2003-12-30 Time 18:27 Sent To P
Notes
2003-12-30 00:00:00PLAN DENIED
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2004-01-03 Cont ID  
Sent By hmoser Date 2003-12-30 Time 18:27 Rev Time 0.33
Received By jleech Date 2004-01-03 Time 05:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-12-09 Cont ID  
Sent By csiegber Date 2003-12-09 Time 10:14 Rev Time 0.00
Received By mmclean Date 2003-12-09 Time 12:02 Sent To I
Notes
***NONE***