Plan Review Stops For Permit 03120481 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-01-28 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-01-28 |
Time |
15:00 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2004-01-28 |
Time |
15:00 |
Sent To |
|
|
Notes |
2004-01-28 00:00:00 | PROOVISO | | | | 1. STORM PANELS REQUIRE A SEPARATE | | PERMIT WITH INSTALLATION SCHEDULE. | | 2. SUBMIT THE FLORIDA PRODUCT APPROVALS | | FOR THE TRUSS ANCHORS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2004-01-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-28 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2004-01-05 |
Time |
15:29 |
Sent To |
|
|
Notes |
2004-01-05 00:00:00 | BUILDING PLAN REVIEW: FAILED | | | | 1. PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, | | 2003 ARE REQUIRED TO COMPLY WITH THE | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | INFORMATION PLEASE SEE THE STATE | | WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A COVER SHEET THAT LISTS | | THE PRODUCT IDENTITY NUMBER FROM THE | | STATE. IF THE PRODUCT DOES NOT HAVE | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | SPECIFIC FORM PER RULE 9B-72. SEE | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | 2. A SEPARATE PERMIT IS REQUIRED FOR | | THE STORM PANELS WITH SCHEDULE FOR | | OPENINGS & ANCHORING DETAIL. | | | | 3. SEE NOTES FROM MECHANICAL & | | ELECTRICAL REVIEWS. | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-05-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2004-05-05 |
Time |
10:32 |
Rev Time |
0.15 |
Received By |
jleahy |
Date |
2004-05-05 |
Time |
10:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-03 |
Time |
13:46 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-26 |
Time |
16:54 |
Sent To |
M |
|
Notes |
2004-01-26 00:00:00 | PLANS STILL REFERENCE ARC FAULT PROTECT- | | ION FOR RECEPTS. | | PLEASE SEE 2002 NEC ALL OUTLETS/ LIGHTS | | SD'S ETC. | | REDLINED ON PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-12-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
16:43 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-12-23 |
Time |
06:33 |
Sent To |
M |
|
Notes |
2003-12-23 00:00:00 | *********** UNSAT ***************** | | | | 1)NOTE; PLEASE MOVE SD SHOWN IN MASTER | | BEDROOM HALL INTO BEDROOM. NFPA-72, LS | | 101 ETC. 8-1.4 | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE SHOWS | | PANEL AS 225A AND RISER SHOWS 200A. | | | | 3)NOTE: PLEASE SEE NOTE FOR 210.12. | | WE ARE NOW UNDER THE 2002 NEC AND HAVE | | BEEN SINCE 7/1/03.REQUIREMENT HAS | | CHANGED. | | | | 4)NOTE: PLEASE PROVIDE ROOM DESIGNATION | | ON PLANS. | | | | 5)NOTE: PLEASE SEE THAT NOTES ARE STILL | | REFERENCING THE 1999 NEC. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | PLEASE NOTE, IF PERMIT IS NOT ISSUED | | BY JAN 10TH, NOC WILL EXPIRE PER FS | | 713. WORK MUST COMMENCE W/IN 90 DAYS | | OF RECORDING NOC. | | DATE ON NOC IS 10/10/03 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-03 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-03 |
Time |
13:50 |
Sent To |
M |
|
Notes |
2004-05-03 00:00:00 | TO PK BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-05-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-03 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-03 |
Time |
13:46 |
Sent To |
E |
|
Notes |
2004-05-03 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-20 |
Time |
16:43 |
Sent To |
E |
|
Notes |
2004-01-20 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2004-01-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-12-09 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-09 |
Time |
10:17 |
Sent To |
|
|
Notes |
2003-12-09 00:00:00 | TO Z | | TO SFD RACK/E |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-05-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-05-07 |
Time |
14:00 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-05-07 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-01-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-03 |
Time |
13:50 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2004-01-28 |
Time |
09:41 |
Sent To |
B |
|
Notes |
2004-01-28 00:00:00 | PROVISO: | | RETURN AIR IS NOT SIZED PROPERLY FOR THE | | MASTER BEDROOM OR THE OTHER BEDROOMS. | | PER 2001 FBC(M) 601.4 EXCEPTION #1 & 4. | | PLEASE SEE THE ATTACHED SCHEDULE FOR | | PROPER SIZING. | | | | PROVIDE REVSION FOR CHANGES PROIR TO | | INSPECTION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-26 |
Time |
16:54 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-12-30 |
Time |
18:27 |
Sent To |
P |
|
Notes |
2003-12-30 00:00:00 | PLAN DENIED | | 1) REFER TO SECTION 307.2.3 AUXILIARY | | DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE | | INSTALLED UNDER ALL COILS ON WITCH | | CONDENSATION WILL OCCUR. | | 2) RETURN AIR REQUIREMENTS TO COMPLY | | WITH THE FLORIDA BUILDING CODE (M) 2003 | | CHANGES.CHANGES WENT INTO EFFECT JULY 1 | | 2003 | | PLAN REVIEW BY HAROLD MOSER | | (561)805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2004-01-03 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-12-30 |
Time |
18:27 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2004-01-03 |
Time |
05:37 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-12-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-09 |
Time |
10:14 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-12-09 |
Time |
12:02 |
Sent To |
I |
|
Notes |
|
|