Plan Review Stops For Permit 03110872 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2004-11-03 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-11-03 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-11-03 |
Time |
08:44 |
Sent To |
|
|
Notes |
2004-11-03 00:00:00 | SUBMITTAL ON 10/26/04 FOR LANDSCAPE | | PLANS RESTAMP. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2004-03-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-27 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-03-17 |
Time |
15:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2004-03-01 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-03-01 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-03-01 |
Time |
15:58 |
Sent To |
|
|
Notes |
2004-03-01 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 2/11/04: | | | | 7A)FIREDOOR CORPORATION PRODUCT | | APPROVAL FOR OUTSWING COMMERCIAL STEEL | | DOOR (MIAMI-DADE NOA# 01-0705.02). | | IT IS NOTED THAT ANOTHER COPY OF THE | | STATEWIDE PRODUCT APPROVAL COVER SHEET | | HAS BEEN PROVIDED AND THIS SHOWS THE | | APPLICATION STATUS AS 'VALIDATED'.THAT | | STATUS DOES NOT EQUATE TO 'APPROVED' AND | | SINCE IT WAS PRINTED ON 1/23/04 IT IS | | NOW SUPERCEDED BY THE CURRENT LISTING. | | 'VALIDATED' IS IN FACT A LOWER STATUS | | THAN THE CURRENT 'PENDING FBC APPROVAL' | | APPLICATION STATUS THAT IS ON THE DCA | | WEBSITE.EITHER APPLY FOR SITE-SPECIFIC | | APPROVAL OF THIS PRODUCT (FORM AVAILABLE | | FROM THIS OFFICE) OR SPECIFY AN | | ALTERNATIVE THAT HAS STATEWIDE PRODUCT | | APPROVAL. | | THE PRODUCT APPROVAL SHEETS SHALL BE | | MARKED, AS APPROPRIATE, TO IDENTIFY | | WHICH PRODUCT OPTIONS/MATERIALS/SIZES | | ARE TO BE USED. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-02-11 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-02-27 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-02-11 |
Time |
10:54 |
Sent To |
|
|
Notes |
2004-02-11 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 12/29/03: | | | | 1) IMPACT FEES. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 6) USP DTC EMBEDDED TRUSS ANCHORS.IT | | IS NOTED THAT SHEET S-2 STATES THAT THE | | UPLIFT CAPACITY OF ONE USP DTC IS 1410#, | | WHICH IS MORE THAN THE CAPACITY STATED | | IN 2003 USP CATALOG.THERE IS NO DTC | | ANCHOR LISTED IN THE 2004 USP CATALOG OR | | ON THEIR WEBSITE.AMEND THE PLAN TO | | SPECIFY AN APPROPRIATE ANCHOR. | | | | 7) THE PRODUCT APPROVAL SHEETS SHALL BE | | MARKED, AS APPROPRIATE, TO IDENTIFY | | WHICH PRODUCT OPTIONS/MATERIALS/SIZES | | ARE TO BE USED. ALSO: | | (A) THE STATEWIDE PRODUCT APPROVAL COVER | | SHEET THAT HAS BEEN PRINTED AND ATTACHED | | TO THE SUBMITTED FIREDOOR CORPORATION | | PRODUCT APPROVAL NOA# 01-0705.02 BUT | | NOTE THAT IT'S APPROVAL STATUS IS | | 'PENDING' (ALSO, THE DRAWING SHEETS ARE | | POOR COPIES).EITHER APPLY FOR SITE- | | SPECIFIC APPROVAL OF THIS PRODUCT (FORM | | AVAILABLE FROM THIS OFFICE) OR SPECIFY | | AN ALTERNATIVE THAT HAS STATEWIDE | | PRODUCT APPROVAL. | | (B) A SEARCH AT THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | SHOWS NO MATCHING STATEWIDE PRODUCT | | APPROVAL FOR THE SUBMITTED SUNSHINE | | WINDOWS MANUFACT. FIXED WINDOW PRODUCT | | APPROVAL NOA# 03-0314.07.EITHER APPLY | | FOR SITE-SPECIFIC PRODUCT APPROVAL | | (USING THE FORM AVAILABLE FROM THIS | | OFFICE) OR SPECIFY AN ALTERNATIVE THAT | | HAS STATEWIDE OR LOCAL PRODUCT APPROVAL. | | | | 8) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-12-29 |
Time |
18:13 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-12-29 |
Time |
18:13 |
Sent To |
|
|
Notes |
2003-12-29 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) IMPACT FEES. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 2) THE STATED PROJECT VALUE WAS UNDER- | | ESTIMATED.CITY OF WEST PALM BEACH | | ESTIMATES THE VALUE AT $35,100.THIS, | | IN ADDITION TO RADON AND FIRE REVIEW | | FEES DUE AND ALLOWING FOR THE $202.00 | | ALREADY PAID, LEAVES AN OUTSTANDING | | PERMIT APPLICATION BALANCE OF $584.72 TO | | BE PAID. | | | | 3) SHEET SP1.01, SITE PLAN.TWO CABANA/ | | CLUBHOUSE BUILDINGS ARE SHOWN IN | | DIFFERENT LOACATIONS, SECTION-1 AND | | SECTION-2.ALSO, THE PERMIT APPLICATION | | FORM STATES SECTION 3-B.AMEND/ANNOTATE | | THE SITE PLAN AND PERMIT APPLICATION | | FORM TO CLARIFY THE LOCATION OF THE | | CABANA/CLUBHOUSE RELEVANT TO THIS PERMIT | | APPLICATION. | | | | 4) FBC* 104.2.4SITE SURVEY.A SIGNED | | AND SEALED SURVEY DRAWING PREPARED BY A | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | 472.025(1) FL. STATUTES) | | | | 5) FBC 1012.1.2THE ENTRANCE GATE SHALL | | OPEN IN THE DIRECTION OF EGRESS. | | | | 6) SHEET S-4.TWO USP DTC EMBEDDED | | TRUSS ANCHORS ARE SPECIFIED AT EACH END | | OF THE HIP GIRDER TRUSS FOR THE MAIN | | (CENTRAL) ROOF.THE 2003 USP CATALOGUE | | STIPULATES THAT DTC "INSTALLATIONS | | SHOULD BE SPACED NO CLOSER TOGETHER THAN | | 8" CENTER-TO-CENTER", THERE IS NO | | 'DOUBLE ANCHOR APPLICATION' CHART. | | AMEND THE PLAN TO SPECIFY AN APPROPRIATE | | ANCHOR. | | | | 7) SUBMIT A PRODUCT APPROVAL FOR THE | | ROOF TILE. THE SUBMITTED M-D PRODUCT | | APPROVAL NOA# 01-0705.02 FOR THE STEEL | | DOOR AND FENESTRATION TESTING LABORATORY | | REPORT FOR THE ALUMINUM FIXED WINDOW ARE | | NO LONGER SUFFICIENT FOR PRODUCT | | APPROVAL PURPOSES IN FLORIDA (SEE NOTE | | BELOW). SUBMIT SUPPORTING INFORMATION OR | | ALTERNATIVE PRODUCT APPROVAL DOCUMENTS. | | NOTE: FL. ADMIN CODE RULE 9B-72 (IN | | EFFECT SINCE OCTOBER 1, 2003) REQUIRES | | THAT PRODUCTS HAVE STATEWIDE, LOCAL OR | | SITE-SPECIFIC PRODUCT APPROVAL.THE | | SUBMITTAL SHOULD INCLUDE THE STATEWIDE | | PRODUCT APPROVAL NUMBER (FL###), | | AVAILABLE FROM THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | 8) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-26 |
Time |
12:42 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-01-26 |
Time |
12:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-12-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-12-02 |
Time |
04:04 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-12-02 |
Time |
03:55 |
Sent To |
|
|
Notes |
2003-12-02 00:00:00 | **************** UNSAT ***************** | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED WITH | | SIGNATUARE AS REQ'D UNDER FS 471.025 AND | | 61G15-23.002. PLEASE NOTE WE WERE INFORM | | ED ON NOV 4TH BY THE FBPE'S THAT INITIAL | | -S WERE NOT ACCEPTABLE. | | | | | | PLEASE SEE COMMENTS FROM ANY OTHER | | REVIEWERS THAT MAY HAVE AN AFFECT ON | | ELECTRICAL PLANS. | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. IF | | THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-01-22 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-01-22 |
Time |
16:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-12-10 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-12-10 |
Time |
11:59 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-12-10 |
Time |
11:59 |
Sent To |
|
|
Notes |
2003-12-10 00:00:00 | ********UNSAT*************************** | | 1) THE GATES SHALL SWING IN THE | | DIRECTION OF TRAVEL FOR EXITING FROM THE | | POOL DECK AND CABANA. | | | | 2) AN EXIT SIGN IS REQUIRED FOR THE MAIN | | ENTRY AND EXIT GATE. | | | | 3) EMERGENCY LIGHTS ARE REQUIRED FOR THE | | RESTROOMS. | | | | 4) THE INTERIOR FINISH SHALL BE CLASS"A" | | OR CLASS"B". | | | | 5) A FIRE EXTINGUISHER IS REQUIRED. | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. IF | | THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | NATE MCCRAY, CAPTAIN | | 805-6722 OR 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-10-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-27 |
Time |
10:31 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-27 |
Time |
10:31 |
Sent To |
B |
|
Notes |
2004-11-01 00:00:00 | SENT TO MICHELLE MCLEAN'S DESK FOR | | RESTAMP | | | 2004-10-27 00:00:00 | TO RB DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-03-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-03-05 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-03-05 |
Time |
10:49 |
Sent To |
|
|
Notes |
2004-03-05 00:00:00 | TO COMM BD#64 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-02-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-18 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-18 |
Time |
11:04 |
Sent To |
P |
|
Notes |
2004-02-18 00:00:00 | TO KS DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-01-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-20 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-20 |
Time |
16:50 |
Sent To |
|
|
Notes |
2004-01-20 00:00:00 | TO COMM BD#46 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-12-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-11-24 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-11-19 |
Time |
08:32 |
Sent To |
|
|
Notes |
2003-11-25 00:00:00 | TO COMM BD#59 | 2003-11-19 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-12-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-12-11 |
Time |
16:00 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2003-12-11 |
Time |
16:00 |
Sent To |
|
|
Notes |
2003-12-11 00:00:00 | VENTILATION FOR THE BATHROOMS - | | - INTAKE LOUVER DOOR | | - EXHAUST 186 CFM PER BATHROOM |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2004-03-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-03-13 |
Time |
08:32 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-03-13 |
Time |
08:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2004-02-27 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-02-27 |
Time |
13:27 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-02-27 |
Time |
13:27 |
Sent To |
B |
|
Notes |
2004-02-27 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | A) FROM PREVIOUS TWO REVIEWS: | | 1) PROVISIONS FOR THOSE WHO HAVE DIFFI- | | CULTY BENDING AND STOOPING SHALL BE MADE | | AT THE DRINKING FOUNTAIN. SECTION | | 11-4.1.3(10)(A). | | 2) SHT P-1 ENGINEER'S SIGNATURE REQUIRED | | ON SEAL PERR FAC 61G15-23.002(1) AND | | FS 471.025. PER FBPE'S RULING INITIALS | | ARE NOT ACCEPTABLE. | | **NOTE THE P-1 SHEETS HAVE BEEN REMOVED | | AND ARE ON FILE FOR REVIEW BY FBPE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2004-01-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-18 |
Time |
11:04 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-01-28 |
Time |
18:34 |
Sent To |
|
|
Notes |
2004-01-28 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FLORIDA ADMIN. CODE | | FLORIDA STATUTES | | | | A) COMMENTS FROM PREVIOUS REVIEW HAVE | | NOT BEEN ADDRESSED. | | 1) SUBMIT DETAIL FOR DRINKING FOUNTAIN | | PER SECTION 11-4.15 AND ALL SUBSECTIONS, | | AND SECTION 11-4.1.3(10)(A) PROVISIONS | | FOR THOSE WHO HAVE DIFFICULTY BENDING OR | | STOOPING. | | 2) SHT P-1 ENGINEER'S SIGNATURE REQUIRED | | ON SEAL PER FAC 61G15-23.002(1) & FS | | 471.025. PER FBPE'S RULING INITIALS ARE | | NOT ACCEPTABLE. | | *** NEW COMMENT*** | | 1B SEE ATTACHED SHEET CONCERNING FLORIDA | | STATUTE 533.80(2(B) DESIGN PROFESSIONAL | | DOCUMENTS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-12-13 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-13 |
Time |
09:30 |
Rev Time |
0.75 |
Received By |
kstevens |
Date |
2003-12-13 |
Time |
09:30 |
Sent To |
|
|
Notes |
2003-12-13 00:00:00 | DENIED | | REFERENCE: FBC-2001 CHAPTER 11 | | FLA. ADMIN. CODE | | FLA. STATUTES | | | | 1) SUBMIT DETAILS FOR ACCESSIBLE FIXTUR- | | ES - DRINKING FOUNTAINS 11-4.15, W/C'S | | 11-4.16, URNAL 11-4.18, LAV'S 11-4.19, | | TOILET ROOMS 11-4.22 AND ALL SUBSECTIONS | | - ALSO PROVISIONS FOR THOSE WHO HAVE | | DIFFICULTY BENDING OR STOOPING, SECTION | | 11-4.1.3(10)(A). | | 2) SHT P-1 ENGINEER'S SIGNATURE REQUIRED | | ON SEAL PER FAC 61G15-23.002(1) & FLA. | | STATUTE 471.025. PER FBPE'S RULING IN- | | ITALS ARE NOT ACCEPTABLE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2004-11-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-11-02 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-11-02 |
Time |
16:24 |
Sent To |
B |
|
Notes |
2004-11-02 00:00:00 | APPROVED RE-STAMP PLANS LANDSCAPE. | | JOHN ROACH, PLANNER 822-1448 MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-11-24 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-11-24 |
Time |
11:21 |
Sent To |
I |
|
Notes |
|
|