Plan Review Stops For Permit 03110816 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2004-02-27 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-02-27 |
Time |
15:59 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2004-02-27 |
Time |
15:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-25 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2004-02-27 |
Time |
15:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-01-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-02-05 |
Time |
12:15 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2004-01-26 |
Time |
11:31 |
Sent To |
|
|
Notes |
2004-01-26 00:00:00 | 1.SUBMIT AN ADDITIONAL COPY OF PRODUCT | | APPROVALS FOR...GLASS MASONARY AND | | JENWELD STEEL DOOR AND PITTSBURG | | SILICONE SYSTEM. | | 2.ENERGY CALCULATIONS NOT SIGNED. | | SUBMIT 2 SIGNED COPIES. | | 3. THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | AND A COPY SUBMITTED TO THIS OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-12-29 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-26 |
Time |
06:53 |
Rev Time |
1.25 |
Received By |
alange |
Date |
2003-12-29 |
Time |
14:46 |
Sent To |
Z |
|
Notes |
2003-12-29 00:00:00 | 1.SUBMIT PRODUCT APPROVALS FOR GLASS | | BLOCK AND #11 FIBERGLASS EXTERIOR DOOR. | | 2.SPECIFY SIZE AND TYPE OF SHEATHINGS | | USED. | | 3.SPECIFY SIZE AND TYPE OF BEAM AND | | COLUMNS USED ON COVERED PORCH . | | 4.SPECIFY TYPES OF SIMPSON TIES USED. | | 5.WEST PALM BEACH AMENDMENT TO | | FLORIDABUILDING CODE 1804.1.7 HABITABLE | | AREAS SHALL BE 4" OBOVE FINISH GRADE. | | SHOW LOCATION OF FINISH GRADE. | | 6.FLORIDA BUILDING CODE 1804.1.3 | | THE BOTTOM OF FOUNDATIONS SHALL EXTEND | | NO LESS THAN 12" BELOW FINISH GRADE. | | 7. SECTION 2... ARE YOU PUTTING TILE ON | | A FLAT ROOF?PLEASE VERIFY ROOFING | | PRODUCTS IN PLAN. | | 8.BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | 9.NOC REQUIRED | | | | ANY QUESTIONS PLEASE CALL ME | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-01-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-01-23 |
Time |
16:48 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-01-23 |
Time |
16:18 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-11-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-21 |
Time |
14:34 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-11-24 |
Time |
17:05 |
Sent To |
P |
|
Notes |
2003-11-24 00:00:00 | | | UNSAT | | ~~~~~ | | ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ | | PLEASE REVISE THE PLANS TO INDICATE THE | | FOLLOWING FOR CODE COMPLIANCE. | | | | 1} PLEASE NOTE THAT ALL PLANS | | DRAWN BY AN ARCHITECT/ENGINEER CONTAIN- | | ING A TITLE BLOCK, MUST BE SIGNED, | | DATED AND SEALED BY THE ARCH/ENGINEER | | OFRECORD. PER FS/FAC 481.221 & 471.025 | | | | 2} PLEASE SEE THAT THE RISER INDICATES | | 3-6/0 CONDUCTORS FEEDING PANEL"B".SHOW | | ACTUAL SIZE.SEE SCHEDULE. | | | | 3} PLEASE NOTE FRONT AND REAR | | RECEPTS REQ`D PER 210.52E. | | | | 4} PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S). PER 210-11-C-3 | | MUST BE 20A AND #12AWG. | | | | 5} PLEASE SHOW ALL OUTLET SPACING | | TO MEET 2',6',12' RULE PER 210.52. | | SEE REVIEWED PLANS. | | | | 6} NOTE # 13 IN ELECTRICAL NOTES | | INCORRECTLY REFERS TO SLEEPING ROOM | | RECEPTACLES BEING ARC FAULT,PLEASE SEE | | 210.12 REFERS TO ALL BRANCH CIRCUITS. | | | | 7} PLEASE NOTE THAT THE 200 AMP EXISTING | | PANEL IS MARKED AS MLO AND SHOWN AS MCB | | ON THE RISER,PLEASE CORRELATE. | | | | 8} PLEASE SHOW THE LOCATION OF THE NEW | | A/C EQUIPMENT ON THE PLAN,AND THE | | LOCATION OF THE DISCONNECTS. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-25 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-25 |
Time |
16:01 |
Sent To |
B |
|
Notes |
2004-02-25 00:00:00 | TO AL DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-01-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-27 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-27 |
Time |
14:51 |
Sent To |
M |
|
Notes |
2004-01-27 00:00:00 | TO PK BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-01-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-21 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-21 |
Time |
14:34 |
Sent To |
E |
|
Notes |
2004-01-21 00:00:00 | TO BT DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-11-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-20 |
Time |
17:04 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-20 |
Time |
17:04 |
Sent To |
E |
|
Notes |
2003-11-20 00:00:00 | TO E/THRU TRADES AND RETURN TO Z FOR | | HISTORIC APPROVAL/DEE |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-02-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-02-05 |
Time |
12:15 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-02-05 |
Time |
12:13 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2004-01-26 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-27 |
Time |
14:51 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-01-26 |
Time |
06:44 |
Sent To |
B |
|
Notes |
2004-01-26 00:00:00 | DENIED: 2ND REQUEST | | 1.RETURN AIR FROM THE MASTER BEDROOM | | IS NOT SIZED PROPERLY.PER 2001 FBC(M) | | EXCEPTION #1 & 3, ALL SUPPLY AIR TO THE | | MASTER SUITE SHALL BE INCLUDED IN THE | | CALCULATION FOR TOTAL SUPPLY AIR.THE | | RETURN SHALL BE A MINIMUM OF 1 1/2 TIMES | | THE SQUARE INCHES OF THE SUPPLY AIR TO | | THAT AREA. | | | | 2.PLEASE CLARIFY DUCT SIZE TO THE | | MASTER SUITE, 20" X 10"?IF THIS IS | | CORRECT THE MINIMUM SIZE FOR THE RETURN | | AIR JUMPER SHALL BE 20". | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-12-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-01-23 |
Time |
16:48 |
Rev Time |
0.35 |
Received By |
pkrauss |
Date |
2003-12-03 |
Time |
09:37 |
Sent To |
B |
|
Notes |
2003-12-03 00:00:00 | DENIED: | | PRE 2001 FBC(M) 601.4 - RETURN AIR IS | | REQUIRED FROM THE MASTER BEDROOM AREA. | | (SEE ATTACHED FOR SIZING REQUIREMENTS) | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-12-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-25 |
Time |
06:49 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-12-22 |
Time |
15:13 |
Sent To |
M |
|
Notes |
2003-12-22 00:00:00 | PASSED PER PAUL SCHIMITZ SIGNED ON PLAN | | ALANGE 12/22/03 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-12-31 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-12-29 |
Time |
14:46 |
Rev Time |
0.00 |
Received By |
sgraham |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|