Plan Review Stops For Permit 03110332 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-04-19 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-04-19 |
Time |
13:34 |
Rev Time |
0.60 |
Received By |
alange |
Date |
2004-04-19 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2004-01-22 |
Time |
09:57 |
Rev Time |
1.00 |
Received By |
alange |
Date |
2004-01-22 |
Time |
09:57 |
Sent To |
|
|
Notes |
2004-01-22 00:00:00 | PROVISO | | BATHROOMS SHALL COMPLY WITH THE | | FOLLOWING. | | 1. FBC 11-4.22.3 CLEAR FLOOR SPACE | | 2. FBC11-4.2.3 WHEEL CHAIR TURNING SPACE | | THE SPACE REQUIRED FOR A WHEEEL CHAIR | | TO MAKE A 180 DEGREE TURN IS A CLEAR | | SPACE OF 60 INCHES. | | SEE ATTACHED DETAIL. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-12-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-12-02 |
Time |
17:26 |
Rev Time |
1.00 |
Received By |
lmartine |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-12-02 00:00:00 | | | BUILDING REVIEW COMMENTS | | | | | | WHEN CHANGING OCCUPANCY USE FROM | | RESIDENTIAL TO COMMERCIAL, ALL AREA'S | | WITHIN THE SPACE SHALL COMPLY WITH | | FLORIDA BUILDING CODE CHAPTER 11 FOR | | ACCESSIBILITY REQUIREMENTS. | | | | | | | | | | | | | | L. MARTINEZ | | 805-6710 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-04-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-04-15 |
Time |
14:37 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-04-15 |
Time |
14:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-03-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-03-08 |
Time |
16:52 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-03-08 |
Time |
16:52 |
Sent To |
|
|
Notes |
2004-03-08 00:00:00 | LETTERS BACK FROM ELECTRICAL INSPECTOR. | | OK. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-01-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-25 |
Time |
09:44 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-02 |
Time |
05:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-11-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-07 |
Time |
06:26 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-11-07 |
Time |
06:26 |
Sent To |
|
|
Notes |
2003-11-07 00:00:00 | ******************** UNSAT ************* | | | | RESIDENTIAL TO COMMERICAL | | | | 1)NOTE: PLEASE SHOW ALL CIRCUITING ON | | PLANS AND CORRELATE WITH PANEL SCHEDULE( | | S) TO BE SUBMITTED. | | PLEASE SEE 700.12E FOR CIRCUITING OF | | EM/EXT LTS. | | | | 2)NOTE: PLEASE SEE 600.5 FOR REQ'D | | SIGN CIRCUIT. | | | | 3)NOTE: PLEASE SHOW LOAD CALC FOR | | COMMERICAL USE. PLEASE INCLUDE ALL | | CONTINUOUS LOADS AT 125%. 215.3,230.42 | | ETC. | | | | PLEASE SEE COMMENTS FROM OTHER REVIEWS | | THAT MAY HAVE AN AFFECT ON ELECTRICAL | | PLANS. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | INSERT NEW SHEETS INTO TWO COMPLETE | | SETS FOR REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2004-04-16 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-04-16 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-04-16 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-12-29 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-12-29 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-12-29 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-11-14 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-11-14 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-11-14 |
Time |
15:44 |
Sent To |
|
|
Notes |
2003-11-14 00:00:00 | 1) PLEASE LABEL AREAS ON PLAN. | | | | 2) PLEASE INDICATE ANY NEW OR EXISTING | | FIRE ALARM EQUIPMENT. | | | | 3) PLEASE INDICATE RATED DEMISING WALLS. | | | | 4) PORTABLE FIRE EXTINGUISHERS ARE | | REQUIRED. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-04-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-02 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-02 |
Time |
10:18 |
Sent To |
|
|
Notes |
2004-04-02 00:00:00 | TO COMM BD#1 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-02-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-25 |
Time |
09:44 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-25 |
Time |
09:44 |
Sent To |
E |
|
Notes |
2004-02-25 00:00:00 | TO DP DESK/SUBMITTAL FROM INSPECTION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-12-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-23 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-23 |
Time |
09:20 |
Sent To |
|
|
Notes |
2003-12-23 00:00:00 | TO COMM BD#6 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-12-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2003-12-02 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2003-11-06 |
Time |
16:04 |
Sent To |
|
|
Notes |
2003-11-06 00:00:00 | TO COMM BD#4 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2004-04-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-04-15 |
Time |
15:11 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-04-15 |
Time |
15:11 |
Sent To |
|
|
Notes |
2004-04-15 00:00:00 | PER CONVERSATION WITH DEBRA NICHOLS, | | EXISTING EQUIP; CARRIER FA4ANC024005AFAA | | (2) UNITS TOTAL AIR WILL NOT EXCEED | | 2,000 CFM, DUCT SMOKE DETECTORS NOT | | REQUIRED.NO COMBUSTIBLES ARE IN THE | | EXISTING RETURN AIR PLENUM. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2004-04-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-04-06 |
Time |
14:46 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-04-06 |
Time |
14:46 |
Sent To |
|
|
Notes |
2004-04-06 00:00:00 | DENIED: | | BUILDING WAS ORIGINALLY APPROVED FOR | | RESIDENTIAL.THE FOLLOWING SHALL BE | | ADDRESSED FOR CODE COMPLIANCE FOR | | COMMERCIAL STANDARDS: | | | | 1.OUTSIDE AIR CALCULATIONS PER 2001 | | FBC(M) 403.3. | | | | 2.INDICATE O.A. INTAKE, DUCT SIZE, | | MATERIAL, AND LAYOUT. | | | | 3.PLEASE CLARIFY RETURN TO THE AHU. | | IS THIS A PLENUM?PER 2001 FBC(M) | | 602.2.1, NO COMBUSTIBLES ALLOWED ABOVE | | THE CEILING IN THE RETURN AIR PLENUM. | | | | 4.DUCT SMOKE DETECTORS REQUIRED WHERE | | SYSTEMS HAVE AN AGGREGATE SUPPLY GREATER | | THAN 2,000 CFM.2001 FBC(M) 606.2.2. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-06 |
Time |
07:45 |
Rev Time |
0.40 |
Received By |
pkrauss |
Date |
2004-01-06 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-12-01 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2003-12-01 |
Time |
17:44 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-12-01 |
Time |
17:44 |
Sent To |
|
|
Notes |
2003-12-01 00:00:00 | PLAN DENIED | | NEED DUCT & GRILL SIZE,AND CFM ON NEW | | A/C VENTS. | | PLAN REVIEW BY HAROLD MOSER | | (561)805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|