Plan Review Details - Permit 03110322
Plan Review Stops For Permit 03110322
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-06 Cont ID  
Sent By btrobaug Date 2004-01-07 Time 09:24 Rev Time 2.00
Received By jgomez Date 2004-01-06 Time 13:46 Sent To E
Notes
2004-01-06 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE SET OF DRAWINGS SUBMI
 TTEDFOR FLORIDA PRODUCT APPROVAL
 REVIEW. DADE COUNTY NOA FOR "PREMDOR
 ENTRY SYSTEMS" IS NOT REFERENCED ON
 FLORIDA PRODUCT APPROVAL REPORT.
 **NOTE: PROVIDE INFORMATION FOR REVIEW
 PRIOR TO DOOR INSTALLATION TO AVOID
 CONFLICT OR DELAYS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-08 Cont ID  
Sent By mmclean Date 2003-12-02 Time 10:47 Rev Time 2.50
Received By jgomez Date 2003-12-08 Time 10:38 Sent To PC
Notes
2003-12-08 00:00:00BUILDING REVIEW CHECKLIST:
 1-PERCENTAGE OF OPENINGS SHOWN ON THE
 SOUTH ELEVATION EXCEEDS THOSE ALLOWED
 BY TABLE 600 FBC 2001.
 **ALSO, SHOW ALL EXISTING OPENINGS ON
 NORTH ELEVATION OF EXISTING BUILDING
 TO CHECK TABLE 600 REQUIREMENTS.
 2-EXISTING FOOTING AT CARPORT AREA SEEMS
 TO BE CONCRETE PAD FOR STEEL COLUMNS.
 HOW IS THE CONCRETE EDGE REINFORCED
 BETWEEN CONCRETE PADS?. NEED FOOTING
 TO BE 12 BELOW GRADE (SEC. 1804.1.3
 FBC 2001 AND SEC. 1804.1.7 OF CITY
 AMENDMENTS TO FBC 2001.
 3-PROVIDE SECTION/DETAIL AT CONNECTION
 OF NEW WOOD FRAMING TO EXISTING STEEL
 COLUMNS. SEC. 104.2.1.2 OF THE CITY
 AMENDMENTS TO FBC 2001.
 4-CLARIFY INFORMATION GIVEN FOR MINIMUM
 DESIGN PRESSURE. SEE COMMENTS ON PLANS
 AND SEC. 1606.1.7 FBC 2001. EG: WHAT'S
 A WIND PRESSURE B?. WHAT'S FS 18PSF?.
 WHAT'S COMPONENT & CLADDING 36/MINUS
 48PSF?.
 5-WALL SECTION ON DRAWING #1: A)REVISE
 TYPE OF NAILS FOR SIMPSON H9. SEE
 SIMPSON CATALOGUE.
 B)SPECIFY NAIL TYPE AND SPACING FOR FLAT
 ROOF SHEATHING AND NEW WALL SHEATHING.
 SEC. 2306 CITY AMENDMENTS TO FBC 2001.
 C)CLARIFY WHERE ISSIMPSON PAHD42
 GOING TO BE INSTALLATED? SEC. 104.2.1
 CITY AMENDMENTS TO FBC 2001.
 D)HOW ARE 2X4'S FASTENED TO BOTTOM PLATE
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.
 E)PROVIDE VENTILATION FOR FLAT ROOF AND
 PITCHED ROOF AS REQUIRED BY SEC.
 2309.7 FBC 2001.
  
 6-PROVIDE FLORIDA STATE PRODUCT APPROVAL
 OR LOCAL PRODUCT APPROVAL FOR DOORS
 WINDOWS, STORM SHUTTERS, FLAT ROOF,
 METAL ROOF (IF REPLACED), FIXED WINDOW
 (SEE SIZE ON PLANS), WALL SIDING
 AS REQUIRED AFTER OCT. 1ST 2003.
 PLEASE, SEE WWW.FLORIDABUILDING.ORG
 FOR SPECIFIC INFORMATION REQUIRED.
 7-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS:
 A)KEY PLAN AND INSTALLATION SCHEDULE.
 B)CLEARLY MARK ON STORM SHUTTERS DWGS
 SPECIFIC MOUNTING CONDITIONS & ANCHOR
 TYPE AND SPACING TO BE USED ACCORDING
 TO DESIGN PRESSURES, EDGE DISTANCE,
 CONNECTION TYPE, PANEL SPAN AND
 STRUCTURE TO BE ATTACHED TO.
  
 8-PROVIDE COMPLETE ENERGY CALCULATIONS
 REPORT AND OWNER/AGENT TO SIGN & DATE
 BOTTOM OF FORM AS WELL.
 9-PAY IMPACT FEES TO PALM BEACH COUNTY.
 BRING BACK STAMPED DRAWINGS AND PAID
 RECEIPT.
 10-OWES $487.29 FOR LOW VALUATION AND
 RADON FEES.
  
  
 *IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ @ 805-6712.
  
 *PLEASE, RETURN REVIEWED SET AFTER
 CORRECTIONS ARE DONE TO ORIGINAL DWGS
 TO EXPEDITE THE REVIEW PROCESS.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-01-07 Cont ID  
Sent By btrobaug Date 2004-01-07 Time 09:24 Rev Time 0.25
Received By btrobaug Date 2004-01-07 Time 09:19 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-19 Cont ID  
Sent By jgomez Date 2004-01-06 Time 13:47 Rev Time 0.50
Received By btrobaug Date 2003-11-19 Time 10:44 Sent To P
Notes
2003-11-19 00:00:00NO ELECTRICAL CONTRACTOR SIGNED ON,ELECT
 RICAL PERMIT REQUIRED PRIOR TO STARTING
 WORK.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-07 Cont ID  
Sent By csiegber Date 2003-12-30 Time 13:31 Rev Time 0.00
Received By jgomez Date 2003-12-30 Time 13:31 Sent To PC
Notes
2003-12-30 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-11-14 Cont ID  
Sent By csiegber Date 2003-11-14 Time 15:52 Rev Time 0.00
Received By csiegber Date 2003-11-14 Time 15:52 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-11-06 Cont ID  
Sent By csiegber Date 2003-11-06 Time 16:46 Rev Time 0.00
Received By csiegber Date 2003-11-06 Time 16:46 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-11-21 Cont ID  
Sent By pkrauss Date 2003-11-21 Time 14:17 Rev Time 0.25
Received By pkrauss Date 2003-11-21 Time 14:11 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2004-01-07 Cont ID  
Sent By kstevens Date 2004-01-07 Time 10:19 Rev Time 0.50
Received By kstevens Date 2004-01-07 Time 10:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-11-20 Cont ID  
Sent By csiegber Date 2003-12-30 Time 13:31 Rev Time 0.33
Received By kstevens Date 2003-11-20 Time 09:11 Sent To  
Notes
2003-11-20 00:00:00DENIED
 REFERENCE: FBC-2001 AMEND. CHAPTER 1
  
 1) ALL DRAWINGS SHALL BEAR THE NAME AND
 SIGNATURE OF THE PERSON RESPONSIBLE FOR
 THE DESIGN. SECTION 104.2.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2003-12-02 Cont ID  
Sent By mmclean Date 2003-12-02 Time 10:35 Rev Time 0.00
Received By mmclean Date 2003-12-02 Time 10:35 Sent To B
Notes
2003-12-02 00:00:0012/2/03 GIVEN TO SAMANTHA THYNG MM

Review Stop Z ZONING
Rev No 1 Status F Date 2003-11-14 Cont ID  
Sent By csiegber Date 2003-11-06 Time 16:46 Rev Time 0.00
Received By mmclean Date 2003-11-14 Time 15:30 Sent To  
Notes
2003-11-14 00:00:0011/14/03 DENIED, NEED 2 COPY OF SURVEY
 CALLED CONTR LEFT MSG MM


Account Summary | Usage Policy | Privacy Policy