Plan Review Details - Permit 03110238
Plan Review Stops For Permit 03110238
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-01-23 Cont ID  
Sent By rmcdouga Date 2004-01-23 Time 14:02 Rev Time 2.00
Received By rmcdouga Date 2004-01-23 Time 13:49 Sent To  
Notes
2004-01-23 00:00:00BUILDING PROVISO
  
 1) SUBMIT CURRENT PRODUCT APPROVALS FOR
 THE FOLLOWING:
 - 16' WIDE OVERHEAD GARAGE DOOR
 - DOUBLE OUTSWING UNGLAZED DOORS (ENTRY)
 - STATE APPROVAL FOR THE BENCHMARK AND
 LEGEND NAME DOORS
  
 2) A SEPARATE PERMIT AND FEES WILL BE
 REQUIRED FOR THE STORM PANELS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2004-01-05 Cont ID  
Sent By csiegber Date 2004-01-21 Time 12:18 Rev Time 1.50
Received By rmcdouga Date 2004-01-05 Time 09:31 Sent To  
Notes
2004-01-05 00:00:00DENIED
  
 1) SUBMIT A COMPLETE SOIL TEST REPORT
 WITH SOIL BEARING CAPACITY AND SOIL
 PREPARATION RECOMMENDATIONS. SEE CITY OF
 WPB AMENDMENTS TO FBC 1804.2.2.
  
 2) REVISE THE HEAD/JAMB (SGD) DETAIL ON
 A5 TO SHOW THAT THE FRAME IS FASTENED
 THROUGH THE 1X BUCK AND INTO THE
 STRUCTURAL SUBSTRATE. CHANGE THE WORDING
 TO STATE "THROUGH" THE P.T. BUCK. SEE
 FBC 1707.4.4.2.
  
 3)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL ON THE
 CITY OF WPB FORM PER RULE 9B-72. SEE
 ATTACHMENT.
  
 4) SUBMIT PRODUCT APPROVALS FOR THE
 FOLLOWING:
 - DOUBLE OUTSWING DOOR UNIT (ENTRY) THE
 ONE SUBMITTED IS FOR A SINGLE DOOR.
 - SINGLE OUTSWING GLAZED DOOR(SIDE DOOR)
 THE ONE SUBMITTED IS FOR DOUBLE GLAZED
 DOORS.
 - STRUCTURAL MULLIONS (THE ONE SUBMITTED
 IS EXPIRED.)
 - 16' WIDE GARAGE DOOR (THE ONE THAT WAS
 SUBMITTED IS EXPIRED.)
  
 5) SUBMIT PRODUCT APPROVALS, KEY PLAN &
 INSTALLATION SCHEDULE FOR STORM PANELS.
 CLEARLY MARK ON THE DRAWINGS THE
 SPECIFIC MOUNTING CONDITIONS AND ANCHOR
 TYPE & SPACING. THIS INFORMATION IS
 REQUIRED AT TIME OF PERMIT OR A SEPARATE
 PERMIT WITH ADDITIONAL FEES WILL BE
 REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-12-18 Cont ID  
Sent By csiegber Date 2003-12-30 Time 13:24 Rev Time 2.50
Received By rmcdouga Date 2003-12-17 Time 16:37 Sent To  
Notes
2003-12-17 00:00:00DENIED
  
 1) THE IMPACT FEE INFORMATION IS NOT
 FILLED IN ON THE STAMP ON SHEET C1. THE
 REVIEW NUMBER AND THE SQUARE FOOTAGE ARE
 REQUIRED TO BE ON THE STAMP.
  
 2) SUBMIT COMPLETE SOIL TEST REPORT WITH
 SOIL BEARING INFORMATION AND SOIL
 PREPARATION RECOMMENDATIONS. SEE CITY OF
 WPB AMENDMENTS TO FBC 1804.2.2.
  
 3) REVISE THE HEAD/JAMB (SGD) DETAIL ON
 A5 TO STATE THAT FRAME IS FASTENED
 THROUGH THE 1X BUCK.
  
 4) PROVIDE A ROOF SHEATHING FASTENER
 SCHEDULE ON THE PLANS. PLANS REFER TO A
 DIAPHRAM NAILING SCHEDULE BUT NONE IS
 PROVIDED.
  
 5) SPECIFY THE UPLIFT VALUES FOR THE
 CONNECTORS IN DETAILS 9 AND 10 ON S4.
  
 6) THE USP HLPTA 75 CONNECTORS SPECIFIED
 IN THE TRUSS ANCHOR SCHEDULE SCHEDULE
 ARE NOT LISTED IN THE 2003 USP CATALOG
 AND ARE NOT LISTED ON THE STATE PRODUCT
 APPROVAL WEBSITE. REVISE THE SCHEDULE
 AND SPECIFY AN APPROVED CONNECTOR.
 SEE 2003 USP CATALOG AND STATE WEBSITE.
  
 7)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL ON THE
 CITY OF WPB FORM PER RULE 9B-72. SEE
 ATTACHMENT.
  
 8) SUBMIT PRODUCT APPROVALS FOR THE
 FOLLOWING:
 - DOUBLE OUTSWING DOOR UNIT (ENTRY)
 - SINGLE OUTSWING GLAZED DOOR(SIDE DOOR)
 - MULLIONS (ONE SUBMITTED IS EXPIRED)
 - 16' WIDE GARAGE DOOR (ALSO EXPIRED)
  
 9) SUBMIT PRODUCT APPROVALS, KEY PLAN &
 INSTALLATION SCHEDULE FOR STORM PANELS.
 CLEARLY MARK ON THE DRAWINGS THE
 SPECIFIC MOUNTING CONDITIONS AND ANCHOR
 TYPE & SPACING. INFO MUST BE SUBMITTED
 OR A SEPARATE PERMIT WILL BE REQUIRED.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-06-23 Cont ID  
Sent By dpalmer Date 2004-06-23 Time 14:35 Rev Time 0.33
Received By dpalmer Date 2004-06-23 Time 14:35 Sent To  
Notes
2004-06-23 00:00:00REDLINED
  
 PLANS ARE UNDER 2002 NEC.
 PLANS CALL FOR 99 NEC.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-18 Cont ID  
Sent By mjacobs Date 2004-06-21 Time 16:18 Rev Time 0.50
Received By btrobaug Date 2003-11-18 Time 09:01 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-21 Cont ID  
Sent By mjacobs Date 2004-06-21 Time 16:17 Rev Time 0.00
Received By mjacobs Date 2004-06-21 Time 16:17 Sent To E
Notes
2004-06-21 00:00:00SENT TO DP DESK/REVISION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-03 Cont ID  
Sent By csiegber Date 2004-05-03 Time 13:48 Rev Time 0.00
Received By csiegber Date 2004-05-03 Time 13:48 Sent To M
Notes
2004-05-03 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-21 Cont ID  
Sent By csiegber Date 2004-01-21 Time 12:18 Rev Time 0.00
Received By csiegber Date 2004-01-21 Time 12:18 Sent To B
Notes
2004-01-21 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-30 Cont ID  
Sent By csiegber Date 2003-12-30 Time 13:24 Rev Time 0.00
Received By csiegber Date 2003-12-30 Time 13:24 Sent To B
Notes
2003-12-30 00:00:00TO RM DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-12-18 Cont ID  
Sent By mmclean Date 2003-11-06 Time 16:55 Rev Time 0.00
Received By csiegber Date 2003-11-05 Time 16:01 Sent To  
Notes
2003-11-07 00:00:00TO SFD RACK/E
2003-11-05 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-05-07 Cont ID  
Sent By pkrauss Date 2004-05-07 Time 14:07 Rev Time 0.30
Received By pkrauss Date 2004-05-07 Time 14:07 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-12-03 Cont ID  
Sent By csiegber Date 2004-05-03 Time 13:48 Rev Time 0.50
Received By hmoser Date 2003-12-03 Time 17:23 Sent To P
Notes
2003-12-03 00:00:00PASS PROVISO
 1) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PAN.AUXILIARY DRAIN PANS SHALL BE
 INSTALLED UNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCUR.
 2) RETURN AIR REQUIREMENTS TO COMPLY
 WITH THE FLORIDA BUILDING CODE (M) 2003
 CHANGES.CHANGES WENT INTO EFFECT JULY 1
 2003
 3) REFER TO SECTION 301.13.1 GROUND
 MOUNTED UNITS
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-12-03 Cont ID  
Sent By hmoser Date 2003-12-03 Time 17:24 Rev Time 0.25
Received By jleech Date 2003-12-03 Time 19:26 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-11-06 Cont ID  
Sent By mmclean Date 2003-11-06 Time 16:55 Rev Time 0.00
Received By mmclean Date 2003-11-06 Time 16:55 Sent To I
Notes
***NONE***