Plan Review Details - Permit 03101950
Plan Review Stops For Permit 03101950
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-01-16 Cont ID  
Sent By rmcdouga Date 2004-01-16 Time 16:20 Rev Time 1.00
Received By rmcdouga Date 2004-01-16 Time 16:20 Sent To  
Notes
2004-01-16 00:00:00SUBMITTED STATE AND LOCAL PRODUCT
 APPROVALS FOR WINDOWS, DOORS, MULLIONS
 AND OH GARAGE DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-12-16 Cont ID  
Sent By csiegber Date 2004-01-16 Time 07:44 Rev Time 2.50
Received By rmcdouga Date 2003-12-16 Time 08:58 Sent To  
Notes
2003-12-16 00:00:00PROVISO
  
 1) SUBMIT STATEWIDE OR LOCAL PRODUCT
 APPROVAL IN ACCORDANCE WITH FAC RULE 9B-
 72, FOR EXTERIOR WINDOWS, DOORS, GARAGE
 DOOR, GLASS BLOCK AND MULLIONS FOR
 REVIEW BEFORE THEY ARE INSTALLED.
  
 2) A SEPARATE PERMIT WILL BE REQUIRED
 FOR THE STORM PANELS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-20 Cont ID  
Sent By dpalmer Date 2003-12-12 Time 07:17 Rev Time 2.50
Received By rmcdouga Date 2003-11-20 Time 10:38 Sent To M
Notes
2003-11-20 00:00:00UNSAT
  
 1) DETAIL 8 ON A8 IS FOR A PRIVACY WALL
 WITH A MAXIMUM HEIGHT OF 6 FEET. THE
 WALL AT THE COVERED REAR PORCH HAS THIS
 DETAIL SPECIFIED. THIS WALL IS INDICATED
 ON THE RIGHT ELEVATION AND THE ROOF
 FRAMING PLAN AS BEING 10' IN HEIGHT AND
 SUPPORTING THE PORCH ROOF. PLEASE
 CLARIFY. REVIEW LOCATION OF GIRDER TRUSS
 ON THIS WALL, VERTICAL REINFORCEMENT OF
 WALL MAY BE NECESSARY AT THIS LOCATION.
  
 2) THE UPLIFT VALUES LISTED IN THE
 CONCRETE TO TRUSS CONNECTOR SCHEDULE ON
 SHEET A5A ARE NOT CORRECT FOR MULTIPLE
 STRAPS. THE VALUES DO NOT DOUBLE FOR 2
 STRAPS OR TRIPLE FOR THREE, ETC. THIS IS
 DUE TO THE PROXIMITY OF THE STRAPS AND
 CONE PULL OUT OF THE CONCRETE. SEE THE
 SIMPSON CATALOG OR CONTACT SIMPSON.
 EXAMPLE: (2) HETA 20 CONNECTORS IN A
 CONCRETE BEAM HAVE AN UPLIFT VALUE OF
 2710# NOT 3030#. PLEASE REVISE.
  
 3) PROVIDE A DETAIL INDICATING HOW THE
 INTERIOR BEARING WALLS ARE ATTACHED TO
 THE EXTERIOR MASONRY WALLS.
  
 4) SPECIFY THE TRUSS BOTTOM CORD LIVE
 LOAD IN THE DESIGN PARAMETERS. SEE FBC
 TABLE 1604.1.
  
 5)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL FORM PER
 RULE 9B-72. SEE ATTACHMENT.
  
 6) SUBMIT THE APPROVED DRAWINGS FOR THE
 GARAGE DOOR.
  
 7) SUBMIT UPDATED DRAWINGS FOR THE OUT-
 SWING STEEL DOOR WITH SIDELITES WHICH
 HAVE THE RENEWAL NOA NUMBER STAMPED ON
 THEM.
  
 8) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS OR APPLY
 UNDER A SEPARATE PERMIT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-05-25 Cont ID  
Sent By dpalmer Date 2004-05-25 Time 16:57 Rev Time 0.33
Received By dpalmer Date 2004-05-25 Time 16:57 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-12-12 Cont ID  
Sent By alange Date 2004-05-24 Time 11:15 Rev Time 0.33
Received By dpalmer Date 2003-12-12 Time 07:17 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-11-06 Cont ID  
Sent By csiegber Date 2003-12-10 Time 11:52 Rev Time 0.50
Received By dpalmer Date 2003-11-06 Time 15:19 Sent To  
Notes
2003-11-06 00:00:00************** UNSAT **********
  
 1)NOTE: PLEASE SEE THAT WE ARE NOW UNDER
 THE 2002 NEC, WHICH CHANGES REQUIREMENTS
 OF 210.12. PLEASE ADJUST.
  
 2)NOTE: PLEASE SEE THAT SEAL MUST BE
 CLEARLY VISABLE AND RAISED.
 PLEASE SEE ALSO SEE THAT WE HAVE BEEN
 NOTIFIED BY THE FBPE'S AND ARCH BOARD
 THAT ARCH'S AND OR ENGINEERS MUST SIGN
 PLANS WITH A SIGNATURE WHERE A MIN OD
 FIRST AND LAST NAME CAN BE VISABLE.
 PER FS481.221.
 61G1-16.004
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-05-24 Cont ID  
Sent By alange Date 2004-05-24 Time 11:15 Rev Time 0.00
Received By alange Date 2004-05-24 Time 11:15 Sent To E
Notes
2004-05-24 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-01-16 Time 07:44 Rev Time 0.00
Received By csiegber Date 2004-01-16 Time 07:44 Sent To B
Notes
2004-01-16 00:00:00TO RM DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-10 Cont ID  
Sent By csiegber Date 2003-12-10 Time 11:52 Rev Time 0.00
Received By csiegber Date 2003-12-10 Time 11:52 Sent To E
Notes
2003-12-10 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-11-22 Cont ID  
Sent By mmclean Date 2003-11-26 Time 10:07 Rev Time 0.00
Received By csiegber Date 2003-10-31 Time 09:55 Sent To  
Notes
2003-11-03 00:00:0010/31/03TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-11-22 Cont ID  
Sent By rmcdouga Date 2003-11-20 Time 13:21 Rev Time 0.50
Received By hmoser Date 2003-11-22 Time 11:47 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-11-08 Cont ID  
Sent By jleech Date 2003-11-08 Time 09:44 Rev Time 0.33
Received By jleech Date 2003-11-08 Time 09:44 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-31 Cont ID  
Sent By lsmith Date 2003-10-31 Time 09:55 Rev Time 0.00
Received By mmclean Date 2003-10-31 Time 15:39 Sent To I
Notes
***NONE***