Plan Review Stops For Permit 03101794 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
F |
Date |
2005-04-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-04-07 |
Time |
10:48 |
Rev Time |
0.25 |
Received By |
jgomez |
Date |
2005-04-07 |
Time |
10:48 |
Sent To |
|
|
Notes |
2005-04-07 00:00:00 | SLIDING GLASS DOOR PRODUCT APPROVAL | | CHECKLIST: | | | | 1- PRODUCT APPROVAL RE-SUBMITTED ON | | FRIDAY 4-1-05. REVIEWED ON MONDAY 4-4-05 | | AND FOUND OUT THAT ENGINEER LETTERS AND | | 8.5" X 11" DRAWINGS WERE NOT SIGNED AND | | SEALED AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTES. | | BILL STAPLES CALLED ENGINEER. SIGNED AND | | SEALED LETTERS WERE RE-SUBMITTED ON | | TUESDAY 4-5-06 BUT 8.5" X 11" DRAWINGS | | WERE NOT. | | NEED THOSE DRAWINGS TO BE SIGNED AND | | SEALED BY ENGINEER. | | | | 2- OTHER CHECKLIST ITEMS ADDRESSED ON | | 3-8-05 ARE STILL NOT RESOLVED. SEE | | ATTACHED COPY. | | | | IF YOU HAVE ANY QUESTIONS. PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
F |
Date |
2005-03-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-03-08 |
Time |
14:41 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2005-03-08 |
Time |
14:36 |
Sent To |
PC |
|
Notes |
2005-03-08 00:00:00 | CHECKLIST: | | 1- SLIDING GLASS DOOR PRODUCT APPROVAL | | COMMENTS FROM BILL STAPLES: | | A) PROVIDE 2 COPIES OF F.B.C COVER SHEET | | FILLED OUT. | | | | B) IF DOORS ARE GOING TO BE INSTALLED IN | | 2 DIFFERENT LOCATIONS, THEN, APPLY FOR | | LOCAL PRODUCT APPROVAL OR APPLY FOR SITE | | SPECIFIC PRODUCT APPROVAL FOR EACH | | HOUSE. | | | | C) WHO IS THE EVALUATION ENTITYIF | | APLYING FOR LOCAL PRODUCT APPROVAL. | | D) EVERY CHANGE DONE TO SIGN AND SEAL | | DRAWINGS MUST BE INITILALIZED AND DATE | | BY THE ENGINEER OF RECORD. | | | | E) INSPECTION FOR CODE COMPLIANCE IS | | REQUIRED BY THE ENGINEER OF RECORD AFTER | | ASSEMBLY IS INSTALLED. | | | | 2- REVISION COMMENTS: | | A) PROVIDE COMPLETE UL LISTING AND SPECS | | FOR INTERIOR FIREPLACE. SEC. 2806 FBC. | | B) PROVIDE COMPLETE LISTING AND SPECS | | FOR BBQ GRILL. SEC. 2808 FBC 2001. | | ****NOTE: MAKE SURE THAT MANUFACTURER | | SPECS ALLOW INSTALLATION OF GRILL IN THE | | PORCH SINCE THEY ARE DESIGN TO BE | | INSTALLED OUTDOORS. | | | | B) MASTER BATHROOM WINDOWS BY THE | | WHIRPOOL NEED TO BE SPECIFIED AS SAFETY | | GLASSS. SEC. 2405.2 FBC 2001. | | | | C) ATTIC SPACE WAS ORIGINALLY DESIGNED | | FOR ATTIC STORAGE WITH 30PSF LIVE LOAD. | | ATTIC WAS REVISED FOR NON-STORAGE. BUT | | NEEDS TO BE DESIGNED FOR 10PSF ATTIC | | LIVE LOAD AS REQUIRED BY TABLE 1604.1 | | FBC 2001. NOW, THE PROBLEM IS THAT ROOF | | TRUSSES WERE DESIGNED FOR 0 PSF ATTIC | | LIVE LOAD. TRUSSES NEED TO COMPLY WITH | | TABLE 1604.1 FBC 2001. | | | | D) BREAKFAST AREA WINDOW IS TO BE USED | | FOR EMERGENCY EGRESS. STORM SHUTTERS | | INSTALLATION SCHEDULE SHOWS WINDOW TO BE | | SHUTTERED. PROVIDE CERTIFICATION THAT | | THIS WINDOW WAS INSTALLED WITH MISSILE | | IMPACT GLAZING IN ORDER TO COMPLY WITH | | SEC. 1005.4.5 FBC 2001. | | | | E) OWES $80.00 REVISION FEES. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
F |
Date |
2005-01-14 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-01-14 |
Time |
14:16 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-01-14 |
Time |
14:16 |
Sent To |
|
|
Notes |
2005-01-14 00:00:00 | CHECKLIST: | | 1-PRODUCT APPROVAL INFORMATION FOR | | SLIDING GLASS DOORS LOCAL PRODUCT | | APPROVAL IS INCOMPLETE. COMPLETE FORM | | REQUIRED BY THE FLORIDA BUILDING | | COMMISSION WHEN APPLYING FOR LOCAL | | PRODUCT APPROVAL AND PROVIDE ALL | | REQUIRED INFORMATION. SEE | | WWW.FLORIDABUILDING.ORG FOR ALL | | INFORMATION REQUIRED TO COMPLY WITH | | CHAPTER 9B-72. | | | | 2-DADE COUNTY NOA IS VOIDED IF SYSTEM | | IS | | ALTERED. INFORMATION SUBMITTED IS | | DIFFERENT THAT ONE SUBMITTED FOR DADE | | COUNTY PRODUCT APPROVAL. | | | | 3-NEED TO VERIFY EMERGENCY EGRESS WHEN | | STORM SHUTTERS ARE INSTALLED.PLANS | | CALL FOR IMPACT GLASS WINDOW AT | | BREAKFAST AREA TO COMPLY WITH THE | | EGRESS | | REQUIREMENT. BUT, ON THE OTHER HAND, | | STORM SHUTTERS INSTALLATION SCHEDULE | | SHOW ALL OPENINGS TO BE PROTECTED WITH | | SHUTTERS INCLUDING THE EGRESS OPENING. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
F |
Date |
2005-01-10 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-01-10 |
Time |
13:10 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-01-10 |
Time |
13:10 |
Sent To |
PC |
|
Notes |
2005-01-10 00:00:00 | REVISION CHECKLIST: | | | | 1-SHEET A4 AND SHEET A5 SPECIFICATIONS | | FOR ATTIC LIVE LOAD DO NOT MATCH. | | BESIDES AREAS TO HAVE STORAGE ARE | | REQUIRED TO BE DESIGNED FOR 30PSF LIVE | | LOAD AS REQUIRED BY TABLE 1604.1 FBC | | 2001. | | | | 2-TRUSS ENGINEER DID NOT FOLLOW | | ARCHITECT'S SPECIFICATIONS REQUIRING | | 30PSF ATTIC LIVE LOAD DESIGN ON AREAS | | DESIGNATED TO BE FOR STORAGE. | | | | 3-FLORIDA OR LOCAL PRODUCT APPROVAL FOR | | SLIDING GLASS DOORS HAS NOT BEING | | RESUBMITTED FOR REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
F |
Date |
2005-01-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2005-01-04 |
Time |
10:49 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2005-01-04 |
Time |
10:49 |
Sent To |
PC |
|
Notes |
2005-01-04 00:00:00 | CHECKLIST: | | 1-DADE COUNTY NOA #02-1206.01 FILE FOR | | SLIDING GLASS DOOR IS SUSPENDED. | | THEREFORE NOA IS NOT ACCEPTABLE. NEED | | CURRENT NOA. | | | | 2-DRAWING #3070HI-900X-XO-1DG IS NOT | | PART OF THE DADE COUNTY NOA PACKAGE. | | THEREFORE IS NOT ACCEPTABLE TO BE PART | | OF THE SAME PRODUCT APPROVAL PACKAGE. | | | | 3-LETTER BY W.W. SCHAEFER ENGINEERING TO | | MODIFY NOA PRODUCT APPROVAL PACKAGE IS | | NOT ACCEPTABLE. SEE NOA TERMINATION | | NOTE. | | | | 4-PROVIDE CURRENT FLORIDA PRODUCT | | APPROVAL OR APPLY FOR LOCAL PRODUCT | | APPROVAL PROVIDING ALL INFORMATION | | REQUIRED ON APPLICATION FOR LOCAL | | PRODUCT APPROVAL. SEE FORM NO | | 9B-72.130(4) FROM RULE CHAPTER 9B-72. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2005-01-04 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-12-27 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2004-12-27 |
Time |
16:02 |
Sent To |
PC |
|
Notes |
2004-12-27 00:00:00 | CHECKLIST: | | 1-COMPLETE FLORIDA OR LOCAL PRODUCT | | APPROVALREQUESTED ON PROVISO DATED | | 2-3-04 FOR SLIDING GLASS DOORS AS SHOWN | | ON PLANS WAS NEVER SUBMITTED. SUBMIT IT | | FOR REVIEW. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2004-12-06 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-12-06 |
Time |
14:23 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2004-12-06 |
Time |
14:23 |
Sent To |
PC |
|
Notes |
2004-12-06 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | 1-ITEMS #3 AND 4 A) WERE NEVER SUBMITTED | | FOR REVIEW. SEE ATTACHED COPY. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2004-07-15 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-07-15 |
Time |
14:27 |
Rev Time |
0.75 |
Received By |
jgomez |
Date |
2004-07-15 |
Time |
14:27 |
Sent To |
PC |
|
Notes |
2004-07-15 00:00:00 | REVISION CHECKLIST: | | 1-PROVIDE COMPLETE FLORIDA OR LOCAL | | PRODUCT APPROVAL FOR ENTRY DOORS WITH | | TRANSOM ABOVE SINGLE ASSEMBLY AS SHOWN | | ON PLANS. | | 2-PROVIDE COMPLETE UL LISTING AND SPECS | | FOR OUTDOOR FIREPLACE AND ANOTHER FOR | | THE INDOOR FIREPLACE AS REQUIRED BY | | SECTION 2806 FBC 2001. | | ARCHITECT OF RECORD TO REVIEW THEM | | PRIOR TO SUBMITTAL TO THIS OFFICE. | | 3-LEFT SIDE EXTERIOR ELEVATION DOESN'T | | SHOW REVISED WINDOW FOR DINING ROOM. | | REVISE AS REQUIRED. | | 4-PROVIDE COMPLETE DETAIL/SPECS FOR | | INSTALLATION OF ARCHED WINDOW ABOVE | | AND SPECIFY IF THERE IS A LINTEL BET. | | BOTTOM AND TOP ROUNDED WINDOW. FRAMING | | PLANS DON'T CALL FOR ANY LINTEL. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 5-PROVIDE ALL INFORMATION REQUESTED ON | | PROVISO DATED 2-3-04. SEE ATTACHED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2004-05-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-05-25 |
Time |
15:27 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2004-05-25 |
Time |
15:27 |
Sent To |
PC |
|
Notes |
2004-05-25 00:00:00 | BUILDING SUBMITTAL CHECKLIST: | | | | **NOTE: | | PROVIDE 2 COPIES OF ANY SUBMITTAL AND | | PLEASE, BRING INFORMATION IN PERSON | | TO FILL OUT PROPER SUBMITTAL FORM AND | | ALLOW TO TRACK SUBMITTALS. | | | | 1-FIREPLACE PACKAGE: A)PROVIDE SPECIFIC | | UL LISTING NUMBER AND MODEL TO VERIFY | | WITH LATEST UL LISTING. | | B)ARCHITECT TO REVIEW FIREPLACE PACKAGE. | | CHECK REQUIRED CLEARANCES & LOCATION | | MEET HIS DESIGN. | | C)REVISE PLANS/ELEVATIONS TO INCLUDE | | CHIMNEY. | | | | 2-ENGINEER CALCS: A)ENGINEER NEEDS TO | | PROVIDE ALL HIS INFORMATION AS REQ'D | | BY CHAPTER 471 FLORIDA STATUTES WHEN | | SUBMITTING INFO. FOR PUBLIC RECORDS. | | ENGINEER TO REVIEW CHAPTER 61G15-23 | | OF THE FLORIDA ADMINISTRATIVE CODE | | FOR SEALS & ENGINEER RESPONSIBILITIES | | 3-PROVIDE ALL INFORMATION AS REQUESTED | | ON PROVISO DATED 2/3/04 PRIOR TO | | INSTALLATION OR CONSTRUCTION TO AVOID | | ANY DELAYS OR CONFLICTS. | | SEE ATTACHED COPY WITH PROVISO. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-02-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-02-06 |
Time |
07:23 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2004-02-03 |
Time |
18:17 |
Sent To |
E |
|
Notes |
2004-02-03 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE LEGIBLE DRAWINGS FOR OUTDOORS | | FIREPLACE AND IDENTIFY UL # LISTED. | | PRIOR TO INSTALLATION. | | 2-PROVIDE COMPLETE/CORRECT INFORMATION | | FOR STORM SHUTTERS UNDER A SEPARATE | | PERMIT. | | 3-PROVIDE ORIGINAL ENGINEERING CALCULATI | | ONS FOR TRUSS ANCHOR SCHEDULE MODIFI- | | CATIONS TO TESTED & PUBLISHED ANCHORS | | BY USP TO COMPLY WITH SEC. 1609.4.3 | | FBC 2001. SEC. 104.2.1.2 CITY AMEND- | | MENTS TO FBC 2001. ALSO, ENGINEER TO | | PROVIDE ALL HIS INFORMATION & PROJECT | | INFORMATION AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTES WHEN SUBMITTING | | INFORMATION FOR PUBLIC RECORDS. | | 4-FLORIDA PRODUCT APPROVAL & DWGS MUST | | MATCH. PROVIDE DRAWINGS THAT MATCH | | SUBMITTED PRODUCT APPROVAL FOR: | | A)SLIDING GLASS DOORS. | | B)ALL STRUCTURAL CONNECTORS SPECIFIED ON | | PLANS. | | C)CASEMENT WINDOWS. | | D)SINGLE HUNG WINDOWS. | | E)WINDOW MULLIONS. | | F)GARAGE DOORS NEED FLORIDA APPROVAL. | | G)MASONITE INTERNATIONAL ENTRY DOORS. | | H)FRENCH DOORS. | | | | NOTE: PROVIDE AL INFORMATION PRIOR TO | | INSTALLATION TO AVOID DELAYS OR CONFLICT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-01-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-28 |
Time |
12:12 |
Rev Time |
4.00 |
Received By |
jgomez |
Date |
2004-01-07 |
Time |
18:34 |
Sent To |
PC |
|
Notes |
2004-01-07 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-MISSING ONE DWG A1 & A2. ONLY ONE COPY | | OF REVISED A1 AND A2 DWG WAS SUBMITTED | | 2-NEED RECORDED NOTICE OF COMMENCEMENT. | | 3-ARCHITECT TO PROVIDE ALL INFORMATION | | LISTED ON SEC. 1606.1.7 FBC 2001. | | 4-WHEN HAVING THE OPTION OF HAVING THE | | FIREPLACE, THEN ALL DETAILS & SPECS | | SHALL BE INCLUDED IN THE CONSTRUCTION | | DOCUMENTS. OTHERWISE, DELETE OPTION. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | 5-LIVING ROOM AREA: PROVIDE COMPLETE | | SECTION/DETAIL AT COLUMN SHOWING HOW | | ARE WINDOWS GOING TO BE ATTACHED. | | **NOTE: CHECK WINDOW PRODUCT APPROVAL | | FOR REQUIRED SUBSTRATE. SEC. 104.2.1.2 | | CITY AMENDMENTS TO FBC 2001. | | 6-PLANS NEED TO SPECIFY SAFETY GLASS AT | | LIVING ROOM WINDOWS. SEC. 2405.2 FBC. | | 7-PROVIDE FLORIDA PRODUCT APPROVAL FOR | | ENTRY DOOR WITH SIZE AS SHOWN ON PLAN. | | 8-ROOF TILE FASTENING SPECIFIED IS NOT | | ADEQUATE. SEE PRODUCT APPROVAL FOR MIN | | REQUIRED SIZES. SEC. 104.2.1.2 CITY | | AMENDMENTS TO FBC 2001. | | 9-RE-SUBMIT FLORIDA PRODUCT APPROVAL FOR | | A)"THERMA-TRU" ENTRY DOORS:*NEED SIZE AS | | SHOWN ON PLANS. **NO GOOD: PENDING FBC | | APPROVAL. ***NEED SWING OF DOOR AS | | SHOWN ON PLANS. ****SLIDING DOOR IS | | MISSING DRAWINGS AND IS PENDING FBC | | APPROVAL. NEED TO CHECK FOR SIZE AND | | SPECIFIC APPLICATION AS SHOWN ON PLANS | | B)GARAGE DOOR PRODUCT APPROVAL IS NOT | | APPROVED YET. IT'S APLIED FOR ONLY. | | C)IF USING FIXED WINDOWS BY "WINDSOR", | | THEN PROVIDE COMPLETE APPROVED DWGS & | | CHECK SIZES SHOWN ON PLANS. | | D)PGT PRODUCT APPROVAL PACKAGE: ONLY | | SUBMIT PRODUCT APPROVAL AND DRAWINGS | | FOR WINDOWS/DOORS, MULLIONS TO BE USED | | ON THIS PROJECT TO AVOID UNNECESSARY | | PAPERWORK. | | **NEED DRAWINGS FOR CASEMENT WINDOWS, | | WINDOW MULLIONS, FIXED WINDOWS (CHECK | | SIZES SHOWN ON PLANS) | | | | 10-NEED FL. PRODUCT APPROVAL FOR FRENCH | | DOORS. CHECK SIZE AND SWING. | | 11-PROVIDE UL LISTING AND COMPLETE SPECS | | FOR FIREPLACE AND BBQ AS REQ'D BY | | SECTIONS 2806 AND 2808 FBC 2001. | | 12-STORM SHUTTERS: A)PROVIDE 2 COPIES | | SIGNED,SEALED AS REQ'D BY ENGINEER. | | B)MEAN ROOF HEIGHT IS INCORRECT. | | C)ACCORDING TO INSTALLATION SCHEDULE | | SOME PANELS WILL ALLOW LESS THAN 2" | | EDGE DISTANCE. REVISE AS REQ'D. | | D)CLEARLY MARK ON ENGINEERED DRAWINGS | | SPECIFIC MOUNTING CONDITIONS & ANCHOR | | TYPE & SPACING TO BE USED ACCORDING TO | | THE DESIGN PRESSURES, EDGE DISTANCE, | | PANEL SPAN, CONNECTION TYPE AND STRUC- | | TURE TO BE ATTACHED TO (CONCRETE BLOCK | | OR CONCRETE). | | E)NEED TO INDICATE EMERGENCY EGRESS AS | | REQ'D BY SECTION 1005.4.5. EGRESS TO | | BE ACCESSIBLE FOR EVERYBODY WITHOUT | | GOING THRU ROOMS THAT MAY BE LOCKED. | | | | 13-CONTRACTOR SAID THAT HE WILL PROVIDE | | ADDITIONAL SOIL BORINGS AS REQ'D BY | | SOIL TEST REPORT. | | 14-PROVIDE FLORIDA PRODUCT APPROVAL FOR | | TRUSS ANCHORS. | | 15-REVISE ENERGY CALCULATIONS: A)UNDER | | ATTIC AREA IS INCORRECT. SEE SECTION | | 604.1.A.1 CHAPTER 13 FBC 2001. | | 16-REVISE TRUSS ANCHOR SCHEDULE: | | A)AVERAGE ULTIMATE TENSION CANN'T BE | | USED FOR DESIGN PURPOSES. SEE SIMPSON | | CONNECTOR HTT22. ALSO, CLARIFY WHAT | | ARE LATERAL FORCES F1 AND F2 TAKEN | | FROM. SEE CATALOGUE. | | **WHERE ARE LATERAL LOADS F1 & F2 TAKEN | | FROM?. PROVIDE ENGINEERING CALCS. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | | | 17-CONTRACTOR TO UPDATE WORKERS COMP. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ @ (561)805-6712. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-12-03 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-06 |
Time |
06:32 |
Rev Time |
3.50 |
Received By |
jgomez |
Date |
2003-12-02 |
Time |
10:49 |
Sent To |
PC |
|
Notes |
2003-12-02 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-NEED RECORDED NOTICE OF COMMENCEMENT. | | 2-ARCHITECT TO PROVIDE COMPLETE INFO. ON | | PLANS AS REQ'D BY SEC. 1606.1.7 FBC. | | 3-CLARIFY IF HAVING THE OPTION OF FIRE- | | PLACE OR NOT. IF SO, THEN PROVIDE | | COMPLETE SECTION/DETAILS AND SPECS FOR | | CHIMNEY AND UL LISTING AND SPECS. | | OTHERWISE REMOVE FIREPLACE AND CHIMNEY | | FROM PLANS ON ORIGINAL DWGS. DON'T | | CROSS OUT ORIGINAL PLANS. | | 4-DESIGN CRITERIA TO INCLUDE 30PSF OR | | 10PSF ATTIC LIVE LOAD AS REQUIRED BY | | TABLE 1604.1 FBC 2001. | | 5-FOOTING DETAILS AND WALL SECTIONS TO | | CLEARLY INDICATE THE 4"MIN. ELEVATION | | ABOVE GRADE AND THE 12" BELOW GRADE | | REQ'D BY SEC. 1804.1.7 CITY AMENDMENTS | | TO FBC AND SEC. 1804.1.3 FBC 2001. | | 6-AS OF OCTOBER 1ST 2003 ALL PRODUCT | | APPROVAL FOR DOORS, WINDOWS AND | | STRUCTURAL COMPONENTS NEED TO HAVE THE | | FLORIDA PRODUCT APPROVAL, LOCAL | | PRODUCT APPROVAL OR SITE SPECIFIC. SEE | | CHAPTER 9B-72 DCA. PLEASE GO TO WWW. | | FLORIDABUILDING. ORG FOR MORE INFO. | | 7-PROVIDE COMPLETE SECTION/DETAIL AND | | SPECS (TOP & BOTT.) FOR STEEL COLS. AT | | FAMILY RM WINDOW. | | **NOTE: INCLUDE ATTACHMENT OF WINDOW TO | | COL. SEE APPROVED PRODUCT APPROVAL. | | 8-SPECIFY ATTIC ACCESS SIZE ON PLANS. | | SEE PLANS AND SEC. 2309.6 FBC 2001. | | 9-SPECIFY SAFETY GLASS WHERE REQUIRED. | | SEE PLANS & SEC. 2405.2 FBC 2001. | | 10-PROVIDE COMPLETE SPECS FOR AHU DETAIL | | INCLUDE SIZE OF BOLTS AND CHAINS. SEC. | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | 11-SPECIFY ROOF TILE FASTENING AS REQ'D | | BY SEC. 104.2.1.1 CITY AMENDMENTS FBC. | | 12-PROVIDE COMPLETE DETAILS/SPECS FOR | | CEILING INSTALLATION AT ENTRY AND REAR | | PORCHES. SEE ASTM C-926 & ASTM C-1063 | | FOR STUCCO AND FASTENER SPECS. | | SEC. 2504.2 FBC 2001. | | 13-INFORMATION ON SURVEY ISN'T COMPLETE. | | IS LOT BEING RECORDED?.SEE DESCRIPTION | | 14-PROVIDE SOIL TEST REPORT W/ COMPLETE | | INFORMATION, SUCH AS SOIL PREPARATION | | AND SOIL BEARING CAPACITY. INFORMATION | | SUBMITTED ALSO RECOMMENDS ADDITIONAL | | BORINGS TO BE PERFORMED FOR FINAL | | GEOTECHNICAL RECOMMENDATIONS. | | 15-STORM SHUTTERS INFO. IS INCOMPLETE. | | NEED FLORIDA PRODUCT APPROVAL. LOCAL | | APPROVAL OR SITE SPECIFIC DRAWINGS. | | ALSO, CLEARLY MARK ON DWGS SPECIFIC | | MOUNTING CONDITIONS AND ANCHOR TYPE & | | SPACING. SEC. 104.2.1.2 CITY AMENDMENT | | TO FBC 2001. | | 16-ENERGY CALCULATIONS: A)REVISE UNDER | | ATTIC AREA. SEE SEC. 604.1.A.1 CHAPTER | | 13 FBC 2001. | | B)CLARIFY HOW ARE INSULATION VALUES | | FOR CONCRETE SLAB, EXTERIOR CONCRETE | | WALL AND UNDER ATTIC GOING TO BE | | ACHIEVED. NOTE: ARCHITECTURAL PLANS & | | ENERGY CALCS NEED TO MATCH. | | 17-SPECIFY FOOTING FOR ENTRY COLUMN. SEE | | FOUNDATION PLAN FOR COMMENTS & RETURN | | REVIEWED SET AFTER CORECTIONS ARE DONE | | TO CAD DWGS TO EXPEDITE REVIEW. | | 18-SPECIFY MULLION/LINTEL ABOVE WINDOWS | | IN FAMILY ROOM. SEE BLDG SECTION A-A. | | SEC. 104.2.1.2 CITY AMENDMENTS TO FBC. | | 19-SHEET A8: A)UPDATE GENERAL NOTES. SEE | | COMMENTS ON PLAN. | | B)COMPLETE/REVISE TYP. WALL SECTION. | | C)COMPLETE INFO. ON AHU DETAIL. | | | | 20-ALL STRUCTURAL CONNECTORS NEED TO | | HAVE FLORIDA PRODUCT APPROVAL AS WELL. | | CHECK WITH USP OR SIMPSON FOR ANCHORS | | THAT HAVE SUCH APPROVAL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE FEEL | | FREE TO CALL JULIO GOMEZ AT 805-6712. | | | | **PLEASE RETURN REVIEWED SET TO EXPEDITE | | THE REVIEW PROCESS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
8 |
Status |
P |
Date |
2005-02-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-02-24 |
Time |
13:15 |
Rev Time |
0.40 |
Received By |
dpalmer |
Date |
2005-02-24 |
Time |
13:15 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
F |
Date |
2005-01-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-01-07 |
Time |
10:18 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2005-01-07 |
Time |
09:45 |
Sent To |
B |
|
Notes |
2005-01-07 00:00:00 | ************** UNSAT *************** | | | | 1)NOTE: PLEASE CORRELATE RISER AND | | PANELS, PANEL "A" SHOWN AS 150A AND | | 200A | | ON RISER. | | PLEASE ALSE SEE PLANS INDICATE A MAIN | | DISC ON THE OUTSIDE OF DWELLING, YET | | RISER DOES NOT CONFRIM THIS.? | | 215.5 | | | | | | 2)NOTE: PLEASE SEE PANEL SCHEDULE | | INDICATES A WHIRLPOOL TUB, HOWEVER, | | PLANS DO NOT INDICATE ANY GFI FOR THIS | | AT WHAT APPEARS TO BE WP TUB AT MASTER | | BATH LOCATION. | | 215.5 | | | | | | 3)NOTE: PLEASE SEE 210.70 FOR REQUIRED | | LT FOR AHU/ EQUIPMENT IN ATTIC. | | | | | | | | 4)NOTE: PLEASE SEE 220.3B4 AN OUTLET | | SUPPLYING RECESSED LUMINAIRE(S) | | [LIGHTING FIXTURE(S)] SHALL BE COMPUTED | | BASED ON THE MAXIMUM VOLT-AMPERE RATING | | OF THE EQUIPMENT AND LAMPS FOR WHICH | | THE | | LUMINAIRE(S) [FIXTURE(S)] IS RATED. | | | | 5)NOTE: PLEASE VERIFY OCP FOR 7.5KW | | AHU#3, SHOWN AS 60A. ONLY A NOTE: | | | | PLEASE SEE ONE SET OF PLANS HAVE BEEN | | REDLINED FOR AREAS OF NOTES AND | | LOCATIONS FOR SOME OF THE ITEMS LISTED | | ABOVE. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW REVISED SHEETS INTO TWO | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2004-11-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-11-18 |
Time |
16:54 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-11-18 |
Time |
16:54 |
Sent To |
|
|
Notes |
2004-11-18 00:00:00 | ************ UNSAT *************** | | | | PLEASE SEE THAT REDLINED ITEMS FROM | | PREVIOUS REVIEWS HAVE NOT BEEN | | ADDRESSED. | | PLEASE ALSO SEE NEW COMMENTS FOR PLAN | | CHANGES. | | | | 1)NOTE: PLEASE SEE 250.24,250.6, THERE | | IS NO EQUIPMENT GROUNDING CONDUCTOR | | FROM | | METER TO FIRST MEANS OF DISCONNECT. | | | | 2)NOTE: PLEASE SEE PLANS STILL NOTE | | MAINS NEXT TO METER.?? | | | | 3)NOTE: PLEASE SEE GROUNDING ELECTRODE | | CONDUCTOR TO BE SIZED PER 250.66. | | ORIG PLANS CALLED FOR SMALLER SERVICE | | AND THIS WAS REDLINED ON PREVIOUS | | REVIEWS. TO BE SIZED PER 250.66 | | | | 4)NOTE: PLEASE SEE HAND DRAWN ITEMS MAY | | NOT BE DONE ON PLANS WHICH ARE SIGNED | | AND SEALED BY AN ARCH OR ENGINEER. | | FS 481.221 | | | | 5)NOTE: PLEASE SEE SD PLACEMENT, | | REQUIRES SD OUTSIDE MASTER BEDRM AND | | ALSO OUTSIDE GUEST SUITE. | | NFPA-72 8-1.4.1.6.2 | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
N |
Date |
2004-07-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-12 |
Time |
11:25 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-07-12 |
Time |
11:25 |
Sent To |
|
|
Notes |
2004-07-12 00:00:00 | NO REV SUBMITTED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-02-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-02-04 |
Time |
10:21 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-02-04 |
Time |
10:21 |
Sent To |
M |
|
Notes |
2004-02-04 00:00:00 | PLANS REVISED, DID NOT REVISE ORIG | | REDLINES. | | REDLINED PLANS FOR GROUNDING ELECTRODE | | CONDUCTOR TO BE SIZED PER 250.66 #2 MIN | | AND MISSING EQUIPMENT GROUNDING CONDUCT- | | ORS BETWEEN MAINS AND PANELS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
N |
Date |
2004-01-28 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2004-02-03 |
Time |
18:17 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2004-01-28 |
Time |
12:12 |
Sent To |
B |
|
Notes |
2004-01-28 00:00:00 | NO CHANGES MADE TO PLANS. PASSED WITH | | REDLINES ON PREVIOUS REVIEW. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-12-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-22 |
Time |
14:04 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2003-12-22 |
Time |
13:16 |
Sent To |
P |
|
Notes |
2003-12-22 00:00:00 | ********** NOTES REDLINED ************ | | | | 1)NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR FROM MAINS TO PANELS | | PER 250.110, 250.24,250.122 | | | | 2)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | CONDUCTOR FROM 250.66./ 310.15B6 | | | | 3)NOTE: PLEASE SEE 210.52 BEDROOM. | | | | ABOVE HAS BEEN REDLINED. IF REV'S ARE | | DONE, PLEASE MAKE ABOVE CORRECTIONS | | AND SUBMIT W/ REVISIONS. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-11-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
11:27 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-11-06 |
Time |
16:40 |
Sent To |
M |
|
Notes |
2003-11-06 00:00:00 | *************** UNSAT **************** | | | | 1)NOTE: PLEASE SHOW ROOM DESIGNATIONS | | ON PLANS. | | | | 2)NOTE: PLEASE SEE 210.52 FOR REQ'D | | RECEPT SPACING. | | | | 3)NOTE: PLEASE SEE 210.52D FOR REQ'D | | RECEPTS TO BE W/IN 3' OF SINKS. | | | | 4)NOTE: PLEASE SEC`S SHOWN AS 1/0'S. | | PLEASE SEE PER 310.16 OR MIN 310.15B6 | | FOR EACH 200A MAIN. | | | | 5)NOTE: PLEASE SEE MISSING GFI RECEPT | | FOR A/C COND UNITS. 210.63 | | | | 6)NOTE: PLEASE LIST THE REQ'D ARC FAULT | | PROTECTED CIRCUITS PER 210.12 OF THE | | 2002 NEC. | | | | 7)NOTE: PLEASE SEE 250.66 FOR SIZING | | OF GR ELEC CONDUCTOR. SEEMS THE #4 AND | | #2 IS REVERSED. | | | | 8)NOTE: PLANS DO NOT SHOW MAIN DISC | | NEXT TO METER. | | | | | | PLEASE REMOVE OLD/VOIDED SHEETS AND | | INSERT NEW SHEETS INTO COMPLETE SETS FOR | | REVIEW AND STAMPING. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
12 |
Status |
N |
Date |
2005-02-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-02-18 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
|
Time |
|
Sent To |
E |
|
Notes |
2005-02-18 00:00:00 | TO DPALMER DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2005-01-10 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-10 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-10 |
Time |
16:08 |
Sent To |
B |
|
Notes |
2005-01-10 00:00:00 | TO "JG" DESK./SUBMITTALS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2005-01-03 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2005-01-03 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2005-01-03 |
Time |
16:15 |
Sent To |
B |
|
Notes |
2005-01-03 00:00:00 | TO "JG" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2004-12-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-12-23 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-12-23 |
Time |
07:26 |
Sent To |
B |
|
Notes |
2004-12-23 00:00:00 | SENT TO "JG" DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-17 |
Time |
13:36 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-11-17 |
Time |
13:36 |
Sent To |
E |
|
Notes |
2004-11-17 00:00:00 | SENT TO "E" TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2004-11-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-11-17 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-11-17 |
Time |
10:48 |
Sent To |
B |
|
Notes |
2004-11-17 00:00:00 | TO JG DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-07-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-06 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-06 |
Time |
10:20 |
Sent To |
|
|
Notes |
2004-07-06 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-07-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-01 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-01 |
Time |
16:08 |
Sent To |
M |
|
Notes |
2004-07-01 00:00:00 | TO PK DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-02-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-27 |
Time |
14:17 |
Sent To |
P |
|
Notes |
2004-02-27 00:00:00 | TO KS BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-01-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-22 |
Time |
14:04 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-22 |
Time |
14:04 |
Sent To |
E |
|
Notes |
2004-01-22 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-16 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-16 |
Time |
11:27 |
Sent To |
E |
|
Notes |
2003-12-16 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-12-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-12-02 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2003-10-30 |
Time |
12:16 |
Sent To |
PC |
|
Notes |
2003-11-04 00:00:00 | 10/30/03TO Z | | TO SFD RACK/E |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
N |
Date |
2004-07-08 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-07-08 |
Time |
11:08 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-07-08 |
Time |
11:08 |
Sent To |
|
|
Notes |
2004-07-08 00:00:00 | CALLED CONTRACTOR, FLOOR PLAN ON THE | | MECHANICAL REVISION SUBMITTED DOES NOT | | MATCH THE FLOOR PLAN ON THE ARCHITECURAL | | DRAWINGS.PLEASE PROVIDE ADDITIONAL | | INFORMATION.LEFT A MESSAGE ON THE | | OFFICE & CEL PHONE ANSWERING MACHINES. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-01 |
Time |
16:08 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2004-02-06 |
Time |
06:57 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-01-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-02-04 |
Time |
10:22 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2004-01-06 |
Time |
06:31 |
Sent To |
B |
|
Notes |
2004-01-06 00:00:00 | REVISED ENERGY CALCS ONLY, PLANS | | APPROVED BY HAROLD MOSER 11-22-03. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-11-22 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-30 |
Time |
10:33 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-11-22 |
Time |
10:46 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2004-03-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-03-05 |
Time |
11:21 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-03-05 |
Time |
11:21 |
Sent To |
|
|
Notes |
2004-03-05 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FLORIDA ADMIN. CODE | | FLORIDA STATUTES | | | | 1) SHT A4 REVISION #4 APPEAR TO BE BLDG. | | REVISIONS AND NOT PLUMBING REVISIONS. | | INDICATE REVISIONS FOR PLUMBING WITH A | | # AND A CLOUD. | | 2) ALL REVISIONS OF A SIGNED AND SEALED | | SET OF PLANS SHALL BE SIGNED, SEALED AND | | DATED BY THE ARCHITECT OF RECORD. SHEET | | SHALL HAVE A TITLE BLOCK AS REQUIRED BY | | 61G1-16.004 WITH ALL INFORMATION REQUIR- | | ED. FS 481.219 | | 3) REVISION SHALL BE IN ISOMETRIC FORM | | WITH CORRECTIONS AS SHOWN ON SHEET A7 | | OF THE STAMPED SET OF PLANS. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2004-02-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-27 |
Time |
14:17 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-02-02 |
Time |
18:43 |
Sent To |
|
|
Notes |
2004-02-06 00:00:00 | PASSED/PROVISO - REVISION REQUIRED - W/M | | REQUIRES A TRAP & STANDPIPE - BATH #3 | | TUB ON RISER, LAV NOT SHOWN - DOWNSTREAM | | OF LAUNDRY ROOM (ON RISER) - SINK NOT | | SHOWN ON FLOOR PLAN - BIDET REQUIRES A | | TRAP. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-12-30 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-30 |
Time |
10:33 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-12-30 |
Time |
10:32 |
Sent To |
M |
|
Notes |
2003-12-30 00:00:00 | PASSED/PROVISO - REVISION REQUIRED - W/M | | REQUIRES A TRAP AND A STANDPIPE, BATH #3 | | TUB NOT SHOWER & LAV NOT SHOWN ON RISER, | | BIDET TRAP TO BE UNDERGROUND, SINK NOT | | FOUND ON FLOOR PLAN. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-12-22 |
Time |
13:16 |
Rev Time |
0.50 |
Received By |
jleech |
Date |
2003-11-24 |
Time |
19:07 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2004-02-04 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2004-02-04 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2004-02-04 |
Time |
09:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-11-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-04 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-11-03 |
Time |
11:12 |
Sent To |
I |
|
Notes |
|
|