Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-13 Cont ID  
Sent By btrobaug Date 2003-10-31 Time 11:53 Rev Time 0.50
Received By sthyng Date 2003-11-13 Time 17:34 Sent To  
Notes
2003-11-13 00:00:00*****CORRECTIONS*****
  
 SAMANTHA THYNG (HILL)
 BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)ENERGY CALCS REQUIRED, FBC13-101.2.
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 3.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED.THE NOTICE OF
 COMMENCEMENT WHICH WAS FILED ON 7/11 HAS
 EXPIRED AS WORK DID NOT COMMENCE WITHIN
 90 DAYS (FS713.13).
  
 4.)THE WALL SECTION DOES NOT SHOW
 CEILING OR WALL INSULATION.PLEASE NOTE
 THAT IF A FORM 600C ENERGY CALC IS
 SUBMITTED, MINIMUM UNDER ATTIC
 INSULATION REQUIRED IS R30, MINIMUM
 WALL INSULATION REQUIRED IS R5.REVISE
 WALL SECTION TO SHOW INSULATION.
  
 5.)SEPARATE PERMITS REQUIRED.
  
 6.)STATEWIDE OR LOCAL PRODUCT APPROVAL
 REQUIRED EFFECTIVE OCTOBER 1.FOR
 LISTED PRODUCTS (CAN SUBMIT THE APPROVAL
 ON THE WEBSITE) WWW.FLORIDABUILDING.ORG.
  
 PLEASE SUBMIT THE STATEWIDE PRODUCT
 APPROVAL WITH THE NOAS.
  
 FOR MORE INFORMATION ABOUT THE PROGRAM,
 SEE THE DCA WEBSITE AT
 WWW.DCA.STATE.FL.US/FHCD/FBC/COMMITTEES/
 PRODUCT_APPROVAL/1_PRODUCT_APPROVAL.HTM

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-10-31 Cont ID  
Sent By lsmith Date 2003-10-30 Time 13:43 Rev Time 0.50
Received By btrobaug Date 2003-10-31 Time 11:28 Sent To B
Notes
2003-10-31 00:00:00 
 PLEASE NOTE THAT AN ELECTRICAL PERMIT IS
 REQUIRED FOR THIS WORK.HAVE THE
 ELECTRICAL CONTRACTOR REFERENCE THIS
 PRIMARY PERMIT NUMBER AT TIME OF
 APPLICATION.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-30 Cont ID  
Sent By lsmith Date 2003-10-30 Time 13:32 Rev Time 0.00
Received By lsmith Date 2003-10-30 Time 13:32 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-30 Cont ID  
Sent By mmclean Date 2003-10-30 Time 12:19 Rev Time 0.00
Received By lsmith Date 2003-10-29 Time 16:50 Sent To Z
Notes
2003-10-29 00:00:00TO MISC BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 12:31 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 12:31 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2003-10-30 Cont ID  
Sent By mmclean Date 2003-10-30 Time 12:19 Rev Time 0.00
Received By mmclean Date 2003-10-30 Time 12:19 Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-10-28 Cont ID  
Sent By lsmith Date 2003-10-30 Time 10:14 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-10-28 00:00:0010/28/03 DENIED, NEED 2 COPY OF SURVEY
 SHOWING WORK FILE C CALLED CONTR MM


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved