Plan Review Details - Permit 03101500
Plan Review Stops For Permit 03101500
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2004-01-16 Cont ID  
Sent By rmcdouga Date 2004-01-16 Time 16:13 Rev Time 1.00
Received By rmcdouga Date 2004-01-16 Time 16:13 Sent To  
Notes
2004-01-16 00:00:00SUBMITTED STATE AND LOCAL PORDUCT
 PRODUCT APPROVALS FOR WINDOWS.DOORS.
 MULLIONS AND OH GARAGE DOOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-12-16 Cont ID  
Sent By csiegber Date 2004-01-16 Time 07:46 Rev Time 2.50
Received By rmcdouga Date 2003-12-16 Time 09:39 Sent To  
Notes
2003-12-16 00:00:00PROVISO
  
 1) STORM PANELS TO BE UNDER SEPARATE
 PERMIT.
  
 2) SUBMIT STATEWIDE OR LOCAL PRODUCT
 APPROVAL IN ACCORDANCE WITH FAC RULE 9B-
 72, FOR EXTERIOR WINDOWS, DOORS, GARAGE
 DOOR AND MULLIONS FOR REVIEW PRIOR TO
 THEIR INSTALLATION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-12-04 Cont ID  
Sent By rmcdouga Date 2003-12-04 Time 11:39 Rev Time 2.00
Received By rmcdouga Date 2003-12-04 Time 11:39 Sent To  
Notes
2003-12-04 00:00:00DENIED
  
 1) THE PRODUCT APPROVAL FOR THE STORM
 PANELS CONTAINS A PAGE OF SPAN TABLES
 THAT STATES IT IS NOT VALID WITHOUT THE
 RAISED SEAL OF THE ENGINEER (BENNARDO).
 THE SPAN FOR A 3" EDGE DISTANCE IS NOT
 IS NOT INDICATED IN THE LAST COLUMN OF
 THE SPAN TABLE. SOME OF THE ANCHORS THAT
 HAVE BEEN HIGHLIGHTED REQUIRE CLOSER
 SPACING OF ANCHORS THAN INDICATED ON THE
 INSTALLATION SCHEDULE.
  
 2)PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72.
 SUBMIT STATE PRODUCT APPROVALS OR
 APPLICATION FOR LOCAL SITE SPECIFIC
 PRODUCT APPROVAL FOR WINDOWS AND DOORS.
  
 3) ADDRESS MECHANICAL ISSUES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-18 Cont ID  
Sent By pkrauss Date 2003-12-03 Time 14:31 Rev Time 3.00
Received By rmcdouga Date 2003-11-18 Time 11:26 Sent To  
Notes
2003-11-18 00:00:00UNSAT
  
 1) THE UPLIFT VALUES LISTED IN THE
 CONCRETE TO TRUSS CONNECTOR SCHEDULE ON
 SHEET A5A ARE INCORRECT FOR MULTIPLE
 STRAPS. THE VALUES DO NOT DOUBLE FOR 2
 STRAPS OR TRIPLE FOR THREE DUE TO THE
 PROXIMITY OF THE STRAPS AND CONE PULLOUT
 OF THE CONCRETE. SEE THE SIMPSON CATALOG
 EXAMPLE: (2) HETA 20 STRAPS EMBEDDED IN
 A CONCRETE TIE BEAM HAS A UPLIFT VALUE
 OF 2710# NOT 3030# LISTED IN THE SCHED.
 ON THE PLANS. PLEASE REVISE.
  
 2) PROVIDE A DETAIL INDICATING THE
 ATTACHMENT OF THE WOOD FRAME INTERIOR
 BEARING WALLS TO THE EXTERIOR MASONRY OR
 CONCRETE WALLS.
  
 3) AN (A5) CONCRETE TO TRUSS CONNECTOR
 IS INCORRECTLY SPECIFIED AT THE WOOD
 FRAME INTERIOR BEARING WALL AT THE
 DINING ROOM ON SHEET A5A. PLEASE CORRECT
  
 4) ON SHEET A5A SECTION 11 ON A8 IS
 INDICATED AT THE INTERIOR KITCHEN WALL.
 PLEASE CLARIFY.
  
 5) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS. A SEPARATE
 PERMIT WILL BE REQUIRED IF NOT SUBMITTED
 AT THIS TIME.
  
 6) PRODUCT APPROVALS FOR APPLICATIONS
 SUBMITTED AFTER OCTOBER 1, 2003 ARE
 REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCT WITH
 STATE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT A COMPLETED
 APPLICATION FOR LOCAL PRODUCT APPROVAL
 PER RULE 9B-72. SEE ATTACHMENT.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CALL:
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-11-04 Cont ID  
Sent By btrobaug Date 2003-11-04 Time 17:42 Rev Time 0.50
Received By btrobaug Date 2003-11-04 Time 17:32 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-01-16 Cont ID  
Sent By csiegber Date 2004-01-16 Time 07:46 Rev Time 0.00
Received By csiegber Date 2004-01-16 Time 07:46 Sent To B
Notes
2004-01-16 00:00:00TO RM DESK/SUBMITTALS

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-08 Cont ID  
Sent By csiegber Date 2003-12-08 Time 09:02 Rev Time 0.00
Received By csiegber Date 2003-12-08 Time 09:02 Sent To M
Notes
2003-12-08 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 16:58 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 16:58 Sent To M
Notes
2003-11-21 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-11-18 Cont ID  
Sent By mmclean Date 2003-10-29 Time 10:36 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 09:43 Sent To  
Notes
2003-10-29 00:00:00TO SFD RACK/E
2003-10-24 00:00:00TO Z

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2003-12-18 Cont ID  
Sent By pkrauss Date 2003-12-18 Time 15:39 Rev Time 0.33
Received By pkrauss Date 2003-12-18 Time 15:39 Sent To  
Notes
2003-12-18 00:00:00APPROVED 12-15-03 PROVISO ON PLAN

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2003-12-03 Cont ID  
Sent By csiegber Date 2003-12-08 Time 09:03 Rev Time 0.40
Received By pkrauss Date 2003-12-03 Time 13:44 Sent To B
Notes
2003-12-03 00:00:00DENIED:
 RETURN AIR SHALL COMPLY WITH REVISION
 TO 2001 FBC(M) 601.4 EFFECTIVE JUNE 30,
 2003.(SEE ATTACHED FOR PROPER SIZING)
  
 PLEASE NOTE RETURN AIR DUCT FOR THE
 MASTER BEDROOM SHALL BE 1 1/2 TIMES
 THE TOTAL OF SUPPLY AIR TO THAT SPACE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-11-06 Cont ID  
Sent By csiegber Date 2003-11-21 Time 16:58 Rev Time 0.50
Received By hmoser Date 2003-11-06 Time 16:57 Sent To P
Notes
2003-11-06 00:00:00PLAN DENIED
 1) RETURN REQUIREMENTS TO COMPLY WITH
 THE F.B.C.(M) 2003 CHANGES.THE CHANGES
 WENT INTO EFFECT JULY 1 2003.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-11-08 Cont ID  
Sent By hmoser Date 2003-11-06 Time 17:03 Rev Time 0.33
Received By jleech Date 2003-11-08 Time 06:28 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-29 Cont ID  
Sent By mmclean Date 2003-10-29 Time 10:36 Rev Time 0.00
Received By shernand Date 2003-12-18 Time 15:32 Sent To I
Notes
2003-12-18 00:00:00PLEASE SEE PLANS FOR ZONING APPROVAL
 BY MICHELLE M.SH