Plan Review Details - Permit 03101317
Plan Review Stops For Permit 03101317
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-12-04 Cont ID  
Sent By lsmith Date 2003-12-04 Time 14:44 Rev Time 1.00
Received By lsmith Date 2003-12-04 Time 14:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-11-03 Cont ID  
Sent By pkrauss Date 2003-12-04 Time 13:58 Rev Time 1.50
Received By lsmith Date 2003-11-03 Time 07:59 Sent To  
Notes
2003-11-03 00:00:00*******BUILDING FAILED*************
  
 1. REPLACE SHEETS IN PLANS THAT WERE
 PHOTOPIED FROM ANOTHER HOUSE PERMIT.
 RESEAL THE PLANS WITH THE RAISED SEAL
 SO IT IS CLEARLY VISABLE PER SS 481.221
  
 2. PHOTO COPY 1ST PAGE OF ENERGY
 EFFICIENCY CODE( IT MUST BE SENT TO THE
 STATE.
  
 3. AFTER PLANS ARE REPLACED TAKE TO PALM
 BEACH COUNTY BUILDING & ZONING AND PAY
 IMPACT FEES, HAVE PLANS STAMPED & SUBMIT
 A COPY OF THE PAID RECEIPT.
  
 4. UPDATE THE PRODUCT APPROVAL FOR THE
 4230 FIXED WINDOWS.THEONES SUBMI
 TTED EXPIRED IN SEPTEMBER 2003.
  
 5. SHECT COMMENTS FROM MECHANICAL PLANS
 EXAMINER.
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-10-27 Cont ID  
Sent By dpalmer Date 2003-10-27 Time 12:23 Rev Time 0.50
Received By dpalmer Date 2003-10-27 Time 12:23 Sent To M
Notes
2003-10-27 00:00:00REDLINED REQUIREMENTS FOR 2002 NEC
 ALSO REDLINED ADDRESS ON E-SHEETS ONLY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-12-01 Cont ID  
Sent By csiegber Date 2003-12-01 Time 16:15 Rev Time 0.00
Received By csiegber Date 2003-12-01 Time 16:15 Sent To M
Notes
2003-12-01 00:00:00TO PK BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-11-08 Cont ID  
Sent By mmclean Date 2003-10-22 Time 15:40 Rev Time 0.00
Received By csiegber Date 2003-10-22 Time 09:58 Sent To  
Notes
2003-10-22 00:00:00TO Z
 TO SFD RACK/E

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-12-04 Cont ID  
Sent By pkrauss Date 2003-12-04 Time 13:58 Rev Time 0.25
Received By pkrauss Date 2003-12-04 Time 13:53 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-10-29 Cont ID  
Sent By csiegber Date 2003-12-01 Time 16:15 Rev Time 0.50
Received By hmoser Date 2003-10-29 Time 18:16 Sent To P
Notes
2003-10-29 00:00:00PLAN DENIED
 1) RETURN AIR WRONG SIZE.REFER TO
 SECTION 601.4 BALANCED RETURN AIR.NEW
 CODE CHANGE WENT INTO EFFECT
 JULY 1 2003.
 2) REFER TO SECTION 307.2.3 AUXILIARY
 DRAIN PANS.AUXILIARY DRAIN PANS SHALL
 BE INSTALLEDUNDER ALL COILS ON WITCH
 CONDENSATION WILL OCCURE.
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-11-08 Cont ID  
Sent By hmoser Date 2003-10-29 Time 18:16 Rev Time 0.33
Received By jleech Date 2003-11-08 Time 05:42 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-10-22 Cont ID  
Sent By mmclean Date 2003-10-22 Time 15:40 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***