Plan Review Details - Permit 03100662
Plan Review Stops For Permit 03100662
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-10-23 Cont ID  
Sent By lsmith Date 2003-10-23 Time 09:07 Rev Time 0.75
Received By lsmith Date 2003-10-23 Time 09:07 Sent To  
Notes
2003-10-23 00:00:00************BUILDING**********
  
 1. THE DOOR SHOWN IN THE DOOR SCHEDULE
 LABELED #1 MUST BE PERMITTED SEPARATELY
 AND PRODUCT APPROVALS SUBMITTED. THESE W
 ERE NOT WITH THIS PERMIT DRAWINGS.
  
  
 ANY QUESTIONSD PLEASE CALL :
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-01-13 Cont ID  
Sent By dpalmer Date 2004-01-13 Time 09:30 Rev Time 0.33
Received By dpalmer Date 2004-01-13 Time 09:30 Sent To  
Notes
2004-01-13 00:00:00REDLINED REQ'D SIGN CIRCUIT PER 600.5
 REDLINED 2002 NEC

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2003-12-16 Cont ID  
Sent By csiegber Date 2004-01-12 Time 15:48 Rev Time 0.50
Received By dpalmer Date 2003-12-16 Time 07:49 Sent To FIRE
Notes
2003-12-16 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE SEE 600.5. REQ'S SIGN
 CIRCUIT. NO OTHER LOADS ARE PERMITTED
 ON CIRCUIT.
  
 2)NOTE: PLEASE SEE LOAD SHOWN FOR WASHER
 /DRYER COMBO. PLEASE VERIFY LOAD. NEC
 220.18 REQ'S A MIN OF 5KW.
  
 3)NOTE: PLEASE ALSO SEE LOAD SHOWN FOR
 COMBO DRYER/WASHER IS 4KW AND IS SHOWN
 ON A 1-POLE 20A BRKR.
  
 4)NOTE: PLEASE SEE LOADFOR RANGE
 SHOWN AT 14KW AND ON A 2P-50A BRKR.
 LOAD EXCEEDS RATING OF BRKR.
  
 5)NOTE: PLEASE SEE LOAD FOR AHU'S.
 LOADS SHOWN AT 10.2KW. PLEASE VERIFY
 MAX OCP. SHOWS 2-P-70A.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-11-18 Cont ID  
Sent By csiegber Date 2003-12-10 Time 16:35 Rev Time 0.30
Received By jleahy Date 2003-11-17 Time 15:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-10-22 Cont ID  
Sent By dpalmer Date 2003-10-22 Time 15:18 Rev Time 0.50
Received By dpalmer Date 2003-10-22 Time 15:18 Sent To  
Notes
2003-10-22 00:00:00********** UNSAT **************
  
 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS
 FOR EXIT AND EM LTS.
 PLEASE ALSO CIRCUIT PER 700.12E
  
 PLEASE REMOVE OLD/VOIDED SHEETS AND
 INSERT NEW FOR REVIEW AND STAMPING.
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-11-24 Cont ID  
Sent By dpalmer Date 2003-12-16 Time 07:49 Rev Time 0.00
Received By mcarsill Date 2003-11-24 Time 16:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-10-31 Cont ID  
Sent By mcarsill Date 2003-10-31 Time 15:49 Rev Time 0.00
Received By mcarsill Date 2003-10-31 Time 15:49 Sent To  
Notes
2003-10-31 00:00:001) ELECTRICAL PLANS DISPLAY NO
 EMERGENCY LIGHTS OR EXIT SIGNS.
  
 2) NO FIRE ALARM EQUIPMENT SHOWN ON
 PLANS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-01-12 Cont ID  
Sent By csiegber Date 2004-01-12 Time 15:48 Rev Time 0.00
Received By csiegber Date 2004-01-12 Time 15:48 Sent To E
Notes
2004-01-12 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-12-10 Cont ID  
Sent By csiegber Date 2003-12-10 Time 16:35 Rev Time 0.00
Received By csiegber Date 2003-12-10 Time 16:35 Sent To E
Notes
2003-12-10 00:00:00TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-11-14 Cont ID  
Sent By csiegber Date 2003-11-14 Time 16:24 Rev Time 0.00
Received By csiegber Date 2003-11-14 Time 16:24 Sent To  
Notes
2003-11-14 00:00:00TO COMM BD#

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-17 Cont ID  
Sent By csiegber Date 2003-10-15 Time 16:40 Rev Time 0.00
Received By csiegber Date 2003-10-17 Time 15:26 Sent To  
Notes
2003-10-15 00:00:00TO COMM BD#22

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-11-24 Cont ID  
Sent By pkrauss Date 2003-11-24 Time 08:31 Rev Time 0.33
Received By pkrauss Date 2003-11-24 Time 08:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-11-13 Cont ID  
Sent By pkrauss Date 2003-11-13 Time 16:12 Rev Time 0.20
Received By pkrauss Date 2003-11-13 Time 16:12 Sent To  
Notes
2003-11-13 00:00:00PROVISO:
 RETURN AIR REQUIRED AS PER 2001 FBC(M)
 601.4 REVISION EFFECTIVE JUNE 30, 2003.
 SEE ATTACHED REQUIREMENTS.PROVIDE
 REVISED PLANS INDICATING RETURN AIR DUCT
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-11-25 Cont ID  
Sent By pschmitz Date 2003-11-25 Time 10:18 Rev Time 1.00
Received By pschmitz Date 2003-11-25 Time 10:18 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-11-04 Cont ID  
Sent By kstevens Date 2003-11-04 Time 13:32 Rev Time 0.50
Received By kstevens Date 2003-11-04 Time 13:32 Sent To  
Notes
2003-11-04 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
  
 1) THESE SPACES WERE RESIDENTIAL OCCU-
 PANCIES. AS A CHANGE OF OCCUPANCY FROM
 RESIDENTIAL TO COMMERCIAL, SECTION
 3402.2.2.1 THE BUILDING, ELECTRICAL, GAS
 MECHANICAL AND PLUMBING SYSTEMS SHALL BE
 MADE TO COMFORM TO THE INTENT OF THE
 TECHNICAL CODES AS REQUIRED BY THE BLDG.
 OFFICIAL.
 2) IF BATHING FACILITIES ARE PROVIDED ON
 A SITE THEN EACH SUCH PUBLIC OR COMMON
 USE BATHING FACILITY SHALL COMPLY WITH
 11-4.23.SECTION 11-4.1.2(6)
 SUBMIT DETAIL FOR FOR BOTH THE TOILET
 ROOM AND THE BATHING SHOWING COMPLIANCE
 WITH SECTIONS 11-4.22, & 11-4.23 AND
 ALL SUBSECTIONS. SHOW COMPLIANCE WITH
 11-4.16, 11-4.19, & 11-4.20 AND ALL SUB-
 SECTIONS. SEE FIGURES 28, 29, 32, 33, &
 34.
 3) BREAKROOM SINK SHALL COMPLY WITH
 SECTION 11-4.24 AND ALL SUBSECTIONS.
 PROVIDE DETAILS.
 4) BATHTUB THAT WILL BE COVERED SHALL
 HAVE THE WASTE AND OVERFLOW SEALED TO
 KEEP SEWER GASSES FROM ESCAPING.
 5) ALL CAPPED WATER AND SANITARY LINES
 SHALL BE INSPECTED PRIOR TO COVERING.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]