Plan Review Stops For Permit 03100662 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-10-23 |
Time |
09:07 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2003-10-23 |
Time |
09:07 |
Sent To |
|
|
Notes |
2003-10-23 00:00:00 | ************BUILDING********** | | | | 1. THE DOOR SHOWN IN THE DOOR SCHEDULE | | LABELED #1 MUST BE PERMITTED SEPARATELY | | AND PRODUCT APPROVALS SUBMITTED. THESE W | | ERE NOT WITH THIS PERMIT DRAWINGS. | | | | | | ANY QUESTIONSD PLEASE CALL : | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-01-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-13 |
Time |
09:30 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-01-13 |
Time |
09:30 |
Sent To |
|
|
Notes |
2004-01-13 00:00:00 | REDLINED REQ'D SIGN CIRCUIT PER 600.5 | | REDLINED 2002 NEC |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-12 |
Time |
15:48 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-12-16 |
Time |
07:49 |
Sent To |
FIRE |
|
Notes |
2003-12-16 00:00:00 | ************ UNSAT *************** | | | | 1)NOTE: PLEASE SEE 600.5. REQ'S SIGN | | CIRCUIT. NO OTHER LOADS ARE PERMITTED | | ON CIRCUIT. | | | | 2)NOTE: PLEASE SEE LOAD SHOWN FOR WASHER | | /DRYER COMBO. PLEASE VERIFY LOAD. NEC | | 220.18 REQ'S A MIN OF 5KW. | | | | 3)NOTE: PLEASE ALSO SEE LOAD SHOWN FOR | | COMBO DRYER/WASHER IS 4KW AND IS SHOWN | | ON A 1-POLE 20A BRKR. | | | | 4)NOTE: PLEASE SEE LOADFOR RANGE | | SHOWN AT 14KW AND ON A 2P-50A BRKR. | | LOAD EXCEEDS RATING OF BRKR. | | | | 5)NOTE: PLEASE SEE LOAD FOR AHU'S. | | LOADS SHOWN AT 10.2KW. PLEASE VERIFY | | MAX OCP. SHOWS 2-P-70A. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-10 |
Time |
16:35 |
Rev Time |
0.30 |
Received By |
jleahy |
Date |
2003-11-17 |
Time |
15:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-22 |
Time |
15:18 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-10-22 |
Time |
15:18 |
Sent To |
|
|
Notes |
2003-10-22 00:00:00 | ********** UNSAT ************** | | | | 1)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | FOR EXIT AND EM LTS. | | PLEASE ALSO CIRCUIT PER 700.12E | | | | PLEASE REMOVE OLD/VOIDED SHEETS AND | | INSERT NEW FOR REVIEW AND STAMPING. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-12-16 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-11-24 |
Time |
16:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-10-31 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-10-31 |
Time |
15:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-10-31 |
Time |
15:49 |
Sent To |
|
|
Notes |
2003-10-31 00:00:00 | 1) ELECTRICAL PLANS DISPLAY NO | | EMERGENCY LIGHTS OR EXIT SIGNS. | | | | 2) NO FIRE ALARM EQUIPMENT SHOWN ON | | PLANS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-01-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-12 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-12 |
Time |
15:48 |
Sent To |
E |
|
Notes |
2004-01-12 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-12-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-10 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-10 |
Time |
16:35 |
Sent To |
E |
|
Notes |
2003-12-10 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-11-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-14 |
Time |
16:24 |
Sent To |
|
|
Notes |
2003-11-14 00:00:00 | TO COMM BD# |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-10-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-15 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-17 |
Time |
15:26 |
Sent To |
|
|
Notes |
2003-10-15 00:00:00 | TO COMM BD#22 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-11-24 |
Time |
08:31 |
Rev Time |
0.33 |
Received By |
pkrauss |
Date |
2003-11-24 |
Time |
08:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-11-13 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-11-13 |
Time |
16:12 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-11-13 |
Time |
16:12 |
Sent To |
|
|
Notes |
2003-11-13 00:00:00 | PROVISO: | | RETURN AIR REQUIRED AS PER 2001 FBC(M) | | 601.4 REVISION EFFECTIVE JUNE 30, 2003. | | SEE ATTACHED REQUIREMENTS.PROVIDE | | REVISED PLANS INDICATING RETURN AIR DUCT | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-11-25 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2003-11-25 |
Time |
10:18 |
Rev Time |
1.00 |
Received By |
pschmitz |
Date |
2003-11-25 |
Time |
10:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-11-04 |
Time |
13:32 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-11-04 |
Time |
13:32 |
Sent To |
|
|
Notes |
2003-11-04 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | | | 1) THESE SPACES WERE RESIDENTIAL OCCU- | | PANCIES. AS A CHANGE OF OCCUPANCY FROM | | RESIDENTIAL TO COMMERCIAL, SECTION | | 3402.2.2.1 THE BUILDING, ELECTRICAL, GAS | | MECHANICAL AND PLUMBING SYSTEMS SHALL BE | | MADE TO COMFORM TO THE INTENT OF THE | | TECHNICAL CODES AS REQUIRED BY THE BLDG. | | OFFICIAL. | | 2) IF BATHING FACILITIES ARE PROVIDED ON | | A SITE THEN EACH SUCH PUBLIC OR COMMON | | USE BATHING FACILITY SHALL COMPLY WITH | | 11-4.23.SECTION 11-4.1.2(6) | | SUBMIT DETAIL FOR FOR BOTH THE TOILET | | ROOM AND THE BATHING SHOWING COMPLIANCE | | WITH SECTIONS 11-4.22, & 11-4.23 AND | | ALL SUBSECTIONS. SHOW COMPLIANCE WITH | | 11-4.16, 11-4.19, & 11-4.20 AND ALL SUB- | | SECTIONS. SEE FIGURES 28, 29, 32, 33, & | | 34. | | 3) BREAKROOM SINK SHALL COMPLY WITH | | SECTION 11-4.24 AND ALL SUBSECTIONS. | | PROVIDE DETAILS. | | 4) BATHTUB THAT WILL BE COVERED SHALL | | HAVE THE WASTE AND OVERFLOW SEALED TO | | KEEP SEWER GASSES FROM ESCAPING. | | 5) ALL CAPPED WATER AND SANITARY LINES | | SHALL BE INSPECTED PRIOR TO COVERING. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|