Plan Review Details - Permit 03100448
Plan Review Stops For Permit 03100448 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-10-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-10 |
Time |
09:08 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2003-10-20 |
Time |
13:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-10 |
Time |
09:27 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2003-10-10 |
Time |
09:27 |
Sent To |
|
|
Notes |
2003-10-10 00:00:00 | ADDITIONAL PERMIT REQUIRED |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-10-07 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-07 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-07 |
Time |
14:01 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-07 |
Time |
14:02 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-10-10 |
Time |
07:38 |
Sent To |
B |
|
Notes |
2003-10-10 00:00:00 | PROVISO: | | 1.REFERENCE FIRST FLOOR DUCTWORK UNDER | | THE HOUSE SHALL NOT BE IN OR WITHIN 6" | | OF THE EARTH AS PER 2001 FBC(M) 603.12. | | | | 2.RETURN AIR FROM BEDROOM AREAS SHALL | | COMPLY WITH THE FOLLOWING: | | REVISION TO THE 2001 FBC(M) 601.4, | | EFFECTIVE JUNE 30,2003: | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM ITS SERVING & THE | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-10 |
Time |
09:27 |
Rev Time |
0.05 |
Received By |
pkrauss |
Date |
2003-10-10 |
Time |
09:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
N |
Date |
2003-10-10 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-10-10 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2003-10-10 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy