Plan Review Stops For Permit 03100433 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
12 |
Status |
P |
Date |
2005-04-27 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-04-26 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-04-26 |
Time |
11:23 |
Sent To |
|
|
Notes |
2005-04-26 00:00:00 | TRUSS ENGINEERING SUBMITTAL ON 4/25/05, | | ORIGINALLY SUBMITTED 3/21/05 (INDEX | | SHEETS ORIGINALLY SUBMITTED ON 3/28/05). |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
11 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2005-04-19 |
Time |
|
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-04-19 |
Time |
10:38 |
Sent To |
|
|
Notes |
2005-04-19 00:00:00 | STRUCTURAL SUBMITTAL FOR PRE-CAST | | SPECIALTIES, INC. LETTER DATED 3/18/05 | | SUMMARIZING SLAB INSPECTION FINDINGS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
F |
Date |
2005-04-19 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-04-19 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-04-19 |
Time |
08:13 |
Sent To |
|
|
Notes |
2005-04-19 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | STRUCTURAL SUBMITTAL ON 4/14/05 FOR | | PRE-CAST SPECIALTIES, INC. PRE-CAST | | HOLLOWCORE SLAB SHOP DRAWINGS AND | | CALCULATIONS. | | | | 1) FBC 1604.1LIVE LOADS.UNDER | | 'LOADING DATA', THE SUBMITTED | | CALCULATIONS STATE A LIVE LOAD OF 30 PSF | | WAS INPUT.SHEET 1, NOTE 11 STATES THE | | SAME.THE REQUIRED LIVE LOAD FOR | | DWELLINGS IS 40 PSF (30 PSF IN SLEEPING | | ROOMS ONLY).AMEND THE PLANS AND | | CALCULATIONS TO DEMONSTRATE COMPLIANCE. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
P |
Date |
2005-04-18 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-04-18 |
Time |
12:53 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-04-18 |
Time |
12:48 |
Sent To |
|
|
Notes |
2005-04-18 00:00:00 | ARCHITECTURAL SUBMITTAL ON 4/14/05 FOR | | ADDITIONAL SHEET A.5 NOTE STATING 'NO | | ATTIC STORAGE' |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
F |
Date |
2005-03-28 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-28 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-28 |
Time |
15:23 |
Sent To |
|
|
Notes |
2005-03-28 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | TRUSS ENGINEERING SUBMITTAL ON 3/21/05 | | AND INDEX SHEET SUBMITTED ON 3/28/05. | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | 1) COMMENT ALREADY ADDRESSED BY | | SUBMITTAL OF CALCULATION INDEX SHEETS. | | BUT, WILL NEED NEW INDEX SHEETS WHEN | | ADDRESSING COMMENTS 2 AND 3 BELOW. | | | | 2) FBC 1604.1ROOF TRUSS LOADING.THE | | SUBMITTED ROOF TRUSS DESIGN CALCULATIONS | | STATE A BOTTOM CHORD LIVE LOAD OF 10PSF. | | THE REQUIRED MINIMUM BOTTOM CHORD LIVE | | LOAD FOR RESIDENTIAL ATTICS WITH STORAGE | | IS 30 PSF.AMEND THE CALCULATIONS. | | | | 3) FBC 1606.1STRESS INCREASE FOR STEEL | | IS NOT ALLOWED.THE WRITERS OF THE | | MITEK SOFTWARE USED FOR DESIGN OF THE | | TRUSSES HAVE ADVISED THAT WHEN THE CODE | | IS STATED AS 'FBC2001/ANSI95' THE | | SOFTWARE USES THE STRESS INCREASE. | | AMEND THE CALCULATIONS TO SHOW | | COMPLIANCE WITH THE PROCEDURE DESCRIBED | | IN THE ATTACHED LETTER FROM MITEK. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2005-03-23 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2005-03-23 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2005-03-23 |
Time |
13:22 |
Sent To |
|
|
Notes |
2005-03-23 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | TRUSS ENGINEERING SUBMITTAL ON 3/21/05. | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | F.S.= FLORIDA (STATE) STATUTE | | | | 1) 471.025 F.S.THE SUBMITTED TRUSS | | LAYOUT AND TRUSS DESIGN SHEETS EACH HAVE | | A STAMPED SIGNATURE OF ALI YEMENICILER, | | P.E.ALL PLANS/DOCUMENTS PREPARED BY A | | PROFESSIONAL ENGINEER AND BEING FILED | | FOR PUBLIC RECORD SHALL BEAR THE | | ENGINEER'S ORIGINAL SIGNATURE.THE | | ORIGINAL SIGNATURE OF THE ENGINEER IS | | REQUIRED ON THE TRUSS LAYOUT AND ON A | | CALCULATION INDEX SHEET THAT LISTS EACH | | TRUSS DESIGN SHEET.IF AN INDEX SHEET | | IS PROVIDED, EACH INDIVIDUAL TRUSS | | DESIGN SHEET DOES NOT REQUIRE A SEAL AND | | ORIGINAL SIGNATURE (REF: 61G15-31.003 | | FLORIDA ADMIN. CODE). | | | | 2) FBC 1604.1ROOF TRUSS LOADING.THE | | SUBMITTED ROOF TRUSS DESIGN CALCULATIONS | | STATE A BOTTOM CHORD LIVE LOAD OF 10PSF. | | THE REQUIRED MINIMUM BOTTOM CHORD LIVE | | LOAD FOR RESIDENTIAL ATTICS WITH STORAGE | | IS 30 PSF.AMEND THE CALCULATIONS. | | | | 3) FBC 1606.1STRESS INCREASE FOR STEEL | | IS NOT ALLOWED.THE WRITERS OF THE | | MITEK SOFTWARE USED FOR DESIGN OF THE | | TRUSSES HAVE ADVISED THAT WHEN THE CODE | | IS STATED AS 'FBC2001/ANSI95' THE | | SOFTWARE USES THE STRESS INCREASE. | | AMEND THE CALCULATIONS TO SHOW | | COMPLIANCE WITH THE PROCEDURE DESCRIBED | | IN THE ATTACHED LETTER FROM MITEK. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2004-10-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-19 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-10-12 |
Time |
13:49 |
Sent To |
|
|
Notes |
2005-04-18 00:00:00 | REVISION FIRST SUBMITTED 6/30/04 FOR | | ADDITION TO PERMITTED BUILDING SIZE. | | AREA WILL BE INCREASED BY 4557 SQ FT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2004-09-21 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-09-21 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-09-21 |
Time |
17:42 |
Sent To |
|
|
Notes |
2004-09-21 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | REVISION FIRST SUBMITTED 6/30/04 FOR | | ADDITION TO PERMITTED BUILDING SIZE. | | AREA WILL BE INCREASED BY 4557 SQ FT | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 7/21/04: | | | | 2) IMPACT FEES. THE AREA OF THE BUILDING | | HAS INCREASED. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE THE REVISION CAN BE | | PERMITTED. | | | | 6) FBC 13-103.0ENERGY CODE COMPLIANCE | | FORMS.THE STATED CONDITIONED AREAS | | STILL DO NOT CORRELATE WITH THE AREAS | | STATED ON THE PLANS. | | (A) ONE FORM IS STATED TO APPLY TO BOTH | | UNITS R9 AND R8.THESE UNITS ARE NOT | | SIMILAR.SHOULD THE FORM BE TITLED | | 'UNIT R7 AND R8' (WHICH ARE SIMILAR, AT | | 1,670 SQFT)? | | (B) IN THAT CASE, SHOULD THE FORM | | CURRENTLY TITLED R7 ACTUALLY BE R9 | | (1,817 SQFT)? | | (C) THE FORM SUBMITTED FOR R10 IS FOR A | | CONDITIONED AREA OF 1987 SQFT.THIS | | DOES NOT CORRELATE WITH THE AREA STATED | | ON THE PLANS, WHICH IS 1,422 SQFT. | | (D) THE FORM SUBMITTED FOR C5 STATES A | | "CONDITIONED FLOOR AREA" OF 1,997 SQFT. | | THE AREA STATED ON THE PLANS IS 960 SQFT | | (E) THE FORM SUBMITTED FOR C8 STATES A | | "CONDITIONED FLOOR AREA" OF 1,040 SQFT. | | THE AREA STATED ON THE PLANS IS | | 1,770 SQFT. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2004-07-21 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-07-21 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-07-21 |
Time |
11:09 |
Sent To |
|
|
Notes |
2004-07-21 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | REVISION SUBMITTED 6/30/04 FOR ADDITION | | TO PERMITTED BUILDING SIZE.AREA WILL | | BE INCREASED BY 4557 SQ FT | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) PERMIT FEES.THE PERMIT AND RADON | | FEES HAVE BEEN REVISED TO REFLECT THE | | INCREASED AREA/VALUATION.THE BALANCE | | OUTSTANDING IS $3349.26 | | | | 2) IMPACT FEES. THE AREA OF THE BUILDING | | HAS INCREASED.THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 3) THE PROPOSED BUILDING STRUCTURE NOW | | TRANSGRESSES LEGAL BOUNDARY LINES | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | 'THE SITE'.SUBMIT A COPY OF THE 'UNITY | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | NOT APPLICABLE. | | | | 4) FBC* 104.2.4SITE SURVEY.THE SITE | | BOUNDARY HAS CHANGED. A REVISED SIGNED | | AND SEALED SURVEY DRAWING PREPARED BY A | | LICENSED SURVEYOR/MAPPER IS REQUIRED. | | (REF: 472.025(1) FL. STATUTES) | | | | 5) ON ONE SET OF PLANS, THE RETAIL AND | | RESIDENTIAL UNIT REFERENCES HAVE BEEN | | STRUCK OUT ON STRUCTURAL PLAN SHEETS | | S1.0, S2.0 AND S3.0 BECAUSE THEY DO NOT | | CORRELATE TO THE REFERENCES ON THE | | ARCHITECTURAL PLANS.AMEND THE OTHER | | TWO SETS TO SUIT. | | | | 6) FBC 13-103.0EACH COPY OF THE | | SUBMITTED ENERGY CODE COMPLIANCE FORMS | | SHALL HAVE THE CORRECT PERMIT NUMBER | | (03100433), PROJECT ADDRESS | | (1930 S DIXIE HWY), AND BUILDER NAME | | ENTERED IN THE ALLOCATED SPACES.ALSO, | | THE STATED UNIT REFERENCES (R6, R7 ETC) | | DO NOT CORRELATE CORRECTLY WITH THE | | 'CONDITIONED AREAS' STATED ON THE CODE | | COMPLIANCE FORMS.SUBMIT COMPLETE AND | | CORRECT FORMS. | | | | 7) FBC 13-101.1.6SHELL RETAIL UNITS. | | THE WHOLE BUILDING (INCL. FUTURE TENANT | | SPACE) SHALL BE CONSIDERED. SHELL RETAIL | | UNITS SHALL BE SHOWN TO COMPLY WITH | | METHOD B (SEE SUB-CHAPTER 4).ALL | | ASSUMPTIONS MADE ABOUT SYSTEMS, NOT | | SHOWN ON THE CURRENT PLANS, SHALL BE | | LISTED AND APPENDED TO THE FORM 400B FOR | | SUBMITTAL.THIS WILL BE COMPARED, AT A | | LATER DATE, TO THE ACTUAL SYSTEMS | | PROPOSED BY THE FUTURE TENANT(S).THE | | ASSUMPTIONS LISTED ON THE APPENDIX SHEET | | SHALL BE AT LEAST THE MINIMUM STANDARD | | (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE | | BUILDING TO BE OCCUPIED FOR IT'S | | INTENDED PURPOSE.SUBMIT CODE | | COMPLIANCE FORMS FOR THE RETAIL UNITS. | | | | 8) FBC 13-103.1.2BEFORE A BUILDING | | PERMIT CAN BE ISSUED, THE SUBMITTED | | ENERGY CODE COMPLIANCE FORMS SHALL BE | | SIGNED BY THE BUILDING OWNER, THE | | OWNER'S ARCHITECT OR OTHER AUTHORIZED | | AGENT LEGALLY DESIGNATED BY THE OWNER. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2004-02-26 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-02-26 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-02-26 |
Time |
08:19 |
Sent To |
|
|
Notes |
2004-02-26 00:00:00 | BUILDING PLAN REVIEW | | ******PROVISO******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | --PROVISO-- | | FIRE SPRINKLERS TO BE INSTALLED AS PER | | FIRE SPRINKLER PERMIT # 03100535 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2004-01-16 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2004-01-16 |
Time |
16:54 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2004-01-16 |
Time |
09:09 |
Sent To |
|
|
Notes |
2004-01-16 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | **BUILDING G** | | **NOTE: READ THESE COMMENTS INDIVIDUALLY | | THEY ARE NOT EXACTLY THE SAME AS THE | | COMMENTS FOR BUILDING H** | | | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | FOR CONSISTENCY, THE FOLLOWING COMMENTS | | ARE NUMBERED AS PER THE BUILDING PLAN | | REVIEW OF 11/18/03: | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | AND A COPY SUBMITTED TO THIS OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 3) 61G1-16.004FL. ADMIN. CODE. SHEETS | | A.1 TO A.20 HAVE A TITLE BLOCK THE | | INCLUDES ONLY THE FIRM'S LICENSE NUMBER | | AA26000691.EACH SHEET SHALL ALSO | | INCLUDE THE PRINTED ARCHITECT'S LICENSE | | NUMBER AR0014128.THE MISSING LICENSE | | NUMBERS MAY BE HANDWRITTEN ON THE PLANS. | | | | 5) FBC 13-103.1.2THIS COMMENT HAS NOT | | BEEN PROPERLY ADDRESSED. THE ONLY ENERGY | | CODE COMPLIANCE FORM THAT HAS BEEN | | SIGNED IS THE FIRST/TOP ONE IN EACH | | PACKAGE (I.E. RESIDENTIAL UNIT 62). NONE | | OF THE FORMS FOR THE OTHER RESIDENTIAL | | UNITS HAS BEEN SIGNED BY THE BUILDING | | OWNER, THE OWNER'S ARCHITECT OR OTHER | | AUTHORIZED AGENT LEGALLY DESIGNATED BY | | THE OWNER. | | | | 6) THIS COMMENT HAS NOT BEEN ADDRESSED. | | FBC 13-101.1.6NO ENERGY CODE | | COMPLIANCE FORMS HAVE BEEN SUBMITTED | | FOR THE FIRST FLOOR COMMERCIAL UNITS. | | THE WHOLE BUILDING (INCL. FUTURE TENANT | | SPACE) SHALL BE CONSIDERED.SHELL | | BUILDINGS SHALL BE SHOWN TO COMPLY WITH | | METHOD B (SEE SUB-CHAPTER 4).ALL | | ASSUMPTIONS MADE ABOUT SYSTEMS, NOT | | SHOWN ON THE CURRENT PLANS, SHALL BE | | LISTED AND APPENDED TO THE FORM 400B FOR | | SUBMITTAL.THIS WILL BE COMPARED, AT A | | LATER DATE, TO THE ACTUAL SYSTEMS | | PROPOSED BY THE FUTURE TENANT(S).THE | | ASSUMPTIONS LISTED ON THE APPENDIX SHEET | | SHALL BE AT LEAST THE MINIMUM STANDARD | | (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE | | BUILDING TO BE OCCUPIED FOR IT'S | | INTENDED PURPOSE. | | | | 11) FBC 1606.2.4SHEET S4.0, WOOD TRUSS | | CONNECTOR MARK D IS STATED AS HAVING AN | | UPLIFT CAPACITY OF 1490#.THE SIMPSON | | HETA 20 WITH 10-10DX1-1/2 NAILS HAS A | | CAPACITY OF 1240#.AMEND THE PLAN. | | | | 12) PRODUCT APPROVALS | | THE PROPOSED PRODUCTS SHALL HAVE STATE- | | WIDE OR LOCAL PRODUCT APPROVAL IN | | ACCORDANCE WITH RULE 9B-72 FAC (FOR | | STATEWIDE PRODUCT APPROVAL SEE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP): | | (A) THE DOOR SCHEDULE, SHEET A.19, | | STATES THAT DOORS 5, 11 & 18 (SECOND | | FLOOR ENTRANCE DOORS TO THE RESIDENTIAL | | UNITS) ARE TO BE IMPACT RATED.THE | | SUBMITTED MIAMI-DADE PRODUCT APPROVAL | | NOA# 02-0109.03 WHICH IS FOR NON-RATED | | FIBERGLASS DOORS.SUBMIT THREE COPIES | | OF A PRODUCT APPROVAL FOR AN ALTERNATIVE | | DOOR. | | NOTE: PRINT AND ATTACH THE RELEVANT | | STATEWIDE PRODUCT APPROVAL LISTING | | REFERENCE SHEET FL### (FOR EXAMPLE, SEE | | SHEET ATTACHED TO EACH OF THE SUBMITTED | | PRODUCT APPROVALS, DURING PLAN REVIEW, | | TO EXPEDITE PERMIT ISSUE). | | | | 14) FBC* 105.3RESIDENT INSPECTOR. | | SUBMIT INSPECTOR RESUME' AND LICENSE | | DOCUMENTS TO HAROLD PISKURA, DIRECTOR OF | | THE RESIDENT INSPECTOR PROGRAM.A | | RESIDENT INSPECTOR PROGRAM IS REQUIRED, | | ON THIS PROJECT, DUE TO THE BUILDING | | BEING OVER 2 STORIES IN HEIGHT. | | | | 15) CONDOMINIUM V APARTMENTS.IF THE | | DWELLING UNITS ARE TO BE SOLD AS | | CONDOMINIUMS, NO CERTIFICATE OF | | OCCUPANCY CAN BE ISSUED UNTIL A | | 'DECLARATION OF CONDOMINIUM' HAS BEEN | | SUBMITTED TO THE STATE FOR APPROVAL, AND | | THEN RECORDED WITH THE CLERK OF THE | | COUNTY COURT.A RECORDED COPY SHALL BE | | SUBMITTED TO THE CITY FOR RECORDS, | | ADDRESSING PURPOSES, AND NOTIFICATION OF | | PALM BEACH COUNTY PROPERTY APPRAISER'S | | OFFICE. | | | | 16) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-11-18 |
|
|
Cont ID |
|
Sent By |
rbrown |
Date |
2003-11-18 |
Time |
20:00 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2003-11-18 |
Time |
20:00 |
Sent To |
|
|
Notes |
2003-11-18 00:00:00 | BUILDING PLAN REVIEW | | *******DENIED******* | | ROBERT BROWN(561) 805 6716 | | E-MAIL: [email protected] | | | | FBC = FLORIDA BUILDING CODE 2001 | | FBC*= FLORIDA BUILD'G CODE (CITY AMEND) | | | | 1) THE NOTICE OF COMMENCEMENT SHALL BE | | RECORDED AT PALM BEACH COUNTY COURTHOUSE | | AND A COPY SUBMITTED TO THIS OFFICE | | BEFORE A PERMIT CAN BE ISSUED.BLANK | | FORMS ARE AVAILABLE FROM THIS OFFICE. | | | | 2) IMPACT FEES. THE PLANS SHALL BE TAKEN | | TO PALM BEACH COUNTY BUILDING DEPARTMENT | | FOR IMPACT FEE ASSESSMENT. THEY SHALL BE | | STAMPED AT THAT OFFICE AND A COPY OF THE | | PAID RECEIPT SUBMITTED TO THE CITY OF | | WEST PALM BEACH DEPT OF CONSTRUCTION | | SERVICES BEFORE A PERMIT CAN BE ISSUED. | | | | 3) 61G1-16.004(6) FACTHE TITLE BLOCK | | ON THE ARCHITECTURAL PLANS SHALL INCLUDE | | THE PRINTED NAME OF THE ARCHITECT | | SEALING THE DOCUMENT. | | | | 4) FBC* 104.2.4SITE SURVEY.A SIGNED | | AND SEALED SURVEY DRAWING PREPARED BY A | | QUALIFIED SURVEYOR IS REQUIRED (REF: | | 472.025(1) FL. STATUTES) | | | | 5) FBC 13-103.1.2THE SUBMITTED ENERGY | | CODE COMPLIANCE FORMS FOR THE | | RESIDENTIAL UNITS SHALL BE SIGNED BY THE | | BUILDING OWNER, OWNER'S ARCHITECT OR | | OTHER AUTHORIZED AGENT LEGALLY | | DESIGNATED BY THE OWNER. | | | | 6) FBC 13-101.1.6NO ENERGY CODE | | COMPLIANCE FORMS HAVE BEEN SUBMITTED | | FOR THE FIRST FLOOR COMMERCIAL UNITS. | | THE WHOLE BUILDING (INCL. FUTURE TENANT | | SPACE) SHALL BE CONSIDERED.SHELL | | BUILDINGS SHALL BE SHOWN TO COMPLY WITH | | METHOD B (SEE SUB-CHAPTER 4).ALL | | ASSUMPTIONS MADE ABOUT SYSTEMS, NOT | | SHOWN ON THE CURRENT PLANS, SHALL BE | | LISTED AND APPENDED TO THE FORM 400B FOR | | SUBMITTAL.THIS WILL BE COMPARED TO THE | | ACTUAL SYSTEMS PROPOSED, AT A LATER, FOR | | INSTALLATION BY THE TENANT(S).THE | | ASSUMPTIONS LISTED ON THE APPENDIX SHEET | | SHALL BE AT LEAST THE MINIMUM STANDARD | | (LIGHTING, HVAC ETC) TO ALLOW THE WHOLE | | BUILDING TO BE OCCUPIED FOR IT'S | | INTENDED PURPOSE. | | | | 7) FBC* F102.2.4ROOF COVERING IN THE | | FIRE DISTRICT.ANNOTATE THE PLANS TO | | SPECIFY FIRE BARRIER BOARD AND AN | | APPROPRIATE UNDERLAYMENT TO ACHIEVE THE | | REQUIRED CLASS A OR B RATING. | | | | 8) FBC* F102.2.7ARCHITECTURAL TRIM ON | | BUILDINGS IN THE FIRE DISTRICT SHALL BE | | CONSTRUCTED OF APPROVED NON-COMBUSTIBLE | | MATERIALS OR FIRE RETARDANT TREATED | | WOOD.THE ELEVATIONS SHOW P.T. CEDAR | | WOOD SHAKE SIDING AND FASCIA, DECORATIVE | | WOOD TRELLIS MEMBERS AND OUTRIGGERS, AND | | WOOD BEAMS.AMEND THE PLANS TO | | DEMONSTRATE COMPLIANCE. | | | | 9) FBC*F102.2.8THE CANVAS AWNING | | SUPPORTS SHALL BE OF NON-COMBUSTIBLE | | MATERIALS AND THE COVERING SHALL BE | | FLAME RESISTANT AS DETERMINED IN | | ACCORDANCE WITH FBC 3103.1.AMEND THE | | PLANS TO DEMONSTRATE COMPLIANCE. | | | | 10) FBC 1604.1SHEET S0.2, | | PRE-ENGINEERED WOOD TRUSSES NOTE 4.THE | | TRUSSES SHALL BE DESIGNED FOR A BOTTOM | | CHORD LIVE LOAD NOT LESS THAN 10 PSF | | (RESIDENTIAL ATTICS WITHOUT STORAGE). | | ANNOTATE THE PLANS TO COMPLY. | | | | 11) FBC 1606.2.4SHEET S4.0, WOOD TRUSS | | CONNECTION MARK B AND C (DOUBLE ANCHORS) | | ARE STATED AS HAVING TWICE THE UPLIFT | | CAPACITY OF A SINGLE ANCHOR.THIS IS | | NOT CORRECT FOR EMBEDDED ANCHORS SUCH | | HETA & HHETA BECAUSE THE FAILURE MODE IS | | INFLUENCED BY OVERLAPPING OF THE | | CONCRETE 'PULL-OUT CONES' FOR THE TWO | | ANCHORS (SEE 2003 SIMPSON CATALOGUE). | | AMEND THE SCHEDULE. | | | | 12) PRODUCT APPROVALS | | THE PROPOSED PRODUCTS SHALL HAVE STATE- | | WIDE OR LOCAL PRODUCT APPROVAL IN | | ACCORDANCE WITH RULE 9B-72 FAC (FOR | | STATEWIDE PRODUCT APPROVAL SEE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP): | | (A) THE SECOND FLOOR ENTRANCE DOORS TO | | THE RESIDENTIAL UNITS ARE SPECIFIED ON | | THE DOOR SCHEDULE AS HOLLOW METAL.THIS | | DOES NOT CORRELATE WITH THE SUBMITTED | | PRODUCT APPROVAL NOA# 02-0109.03 WHICH | | IS FOR FIBERGLASS DOORS.AMEND THE DOOR | | SCHEDULE OR SUBMIT A RELEVANT DOOR | | PRODUCT APPROVAL. | | (B) THE SUBMITTED ALUMINUM FRENCH DOOR | | PRODUCT APPROVAL NOA# 02-0701.12 DOES | | CORRELATE WITH A STATEWIDE PRODUCT | | APPROVAL (#FL253) BUT IT IS A POOR COPY | | AND IS ALSO MISSING DRAWING SHEET | | 2 OF 4.SUBMIT TWO LEGIBLE COPIES OF A | | COMPLETE PRODUCT APPROVAL. | | (C) THE SUBMITTED KAWNEER STOREFRONT | | DOOR PRODUCT APPROVAL NOA# 02-0523.05 | | DOES CORRELATE WITH A STATEWIDE PRODUCT | | APPROVAL (#FL629) BUT IT IS A POOR COPY. | | SUBMIT TWO LEGIBLE COPIES OF THE PRODUCT | | APPROVAL. | | (D) THE SUBMITTED KAWNEER WINDOW WALL | | PRODUCT APPROVAL NOA# 02-0220.01 DOES | | CORRELATE WITH A STATEWIDE PRODUCT | | APPROVAL (FL#627) BUT ONLY ONE COPY WAS | | SUBMITTED BETWEEN BUILDINGS G & H. | | SUBMIT NOT LESS THAN TWO COPIES PER | | BUILDING. | | (E) THE SUBMITTED PGT INDUSTRIES | | ALUMINUM SINGLE HUNG WINDOW | | NOA# 02-0419.13 DOES CORRELATE WITH A | | STATEWIDE PRODUCT APPROVAL (#FL239) BUT | | ONLY ONE COPY WAS SUBMITTED BETWEEN | | BUILDINGS G & H.SUBMIT NOT LESS THAN | | TWO COPIES PER BUILDING. | | (F) THE SUBMITTED PGT INDUSTRIES | | ALUMINUM FIXED WINDOW NOA# 02-0806.04 | | DOES CORRELATE WITH A STATEWIDE PRODUCT | | APPROVAL (#FL243) BUT THIS PRODUCT HAS | | NO IMPACT RATING SO SHUTTERS WILL BE | | REQUIRED.ALSO ONLY ONE COPY WAS | | SUBMITTED BETWEEN BUILDINGS G & H. | | SUBMIT NOT LESS THAN TWO COPIES PER | | BUILDING AND SUBMIT A CORRESPONDING | | PRODUCT APPROVAL FOR THE PROPOSED | | SHUTTERS OR IMPACT RATED FIXED WINDOWS. | | (G) SUBMIT AT LEAST TWO COPIES OF A | | PRODUCT APPROVAL FOR IMPACT RATED | | MULLIONS TO SUIT THOSE WINDOW | | CONFIGURATIONS WHICH REQUIRE WINDOWS TO | | BE MULLED TOGETHER. | | (H) THE SUBMITTED MBCI 5V CRIMP PANEL | | PRODUCT APPROVAL NOA# 02-0628.02 DOES | | NOT CORRELATE WITH ANY STATEWIDE PRODUCT | | APPROVAL.SPECIFY A PRODUCT THAT HAS | | STATEWIDE OR LOCAL PRODUCT APPROVAL. | | (I) THE SUBMITTED ELK CORP. VERSASHIELD | | UNDERLAYMENT PRODUCT APPROVAL | | NOA# 02-0327.03 DOES NOT CORRELATE WITH | | ANY STATEWIDE PRODUCT APPROVAL.SPECIFY | | A PRODUCT THAT HAS A STATEWIDE PRODUCT | | APPROVAL. | | (J) NOTE: | | THE PRODUCT APPROVAL SHEETS SHALL BE | | MARKED, AS APPROPRIATE TO IDENTIFY WHICH | | PRODUCT OPTIONS/MATERIALS/SIZES ARE TO | | BE USED. | | (K) NOTE: | | STATEWIDE PRODUCT APPROVAL STATUS CAN | | BE CHECKED AT THE DEPT OF COMMUNITY | | AFFAIRS PRODUCT APPROVAL WEBSITE | | WWW.FLORIDABUILDING.ORG/PR/PR_SRCH.ASP | | | | 13) IF NEW PLAN SHEETS ARE REQUIRED, IN | | ORDER TO ADDRESS THE ABOVE COMMENTS, THE | | OLD SHEETS SHALL BE REMOVED AND THE NEW | | SHEETS INSERTED.ONE COPY OF EACH OLD | | SHEET SHALL BE INCLUDED WITH THE | | RESUBMITTAL FOR COMPARISON OF REVISIONS. | | | | **QUOTE PERMIT# ON ALL CORRESPONDENCE** | | | | END OF REVIEW COMMENTS | | THE CODE REFERENCES GIVE ADDITIONAL INFO | | TELEPHONE: (561) 805 6716ROBERT BROWN | | E-MAIL: [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2005-11-15 |
Time |
10:46 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2005-11-15 |
Time |
10:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2004-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-10-22 |
Time |
11:49 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2004-10-22 |
Time |
11:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2004-08-25 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-25 |
Time |
10:08 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-08-25 |
Time |
10:08 |
Sent To |
|
|
Notes |
2004-08-25 00:00:00 | ** UNSAT ** | | | | 1)NOTE: PLEASE SEE SHEETS E-1, AND E-5 | | STILL NEED TO BE SIGNED BY THE ENGINEER | | WITH FULL SIGNATURE. | | FS 471.025 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2004-07-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-07-13 |
Time |
10:18 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2004-07-13 |
Time |
09:40 |
Sent To |
|
|
Notes |
2004-07-13 00:00:00 | ************* UNSAT ***************** | | | | 1)NOTE: PLEASE HAVE PLANS SIGNED BY | | ENGINEER WITH FULL LEGAL SIGNATURE AS | | SHOWN ON ORIGINAL PLANS FILE WITH ORIG- | | -INAL PLANS AND PERMIT. | | FS 471.025 | | | | 2)NOTE: PLEASE CORRELATE RISER AND UNITS | | SHOWN ON PLANS ALONG WITH LOAD CALCULAT- | | -IONS.PLEASE ALSO CORRELATE WITH PANEL | | SCHEDULES. | | SOME UNITS DO NOT MATCH. | | | | 3)NOTE: PLEASE SEE 210.52 FOR MISSING | | RECEPTS ALONG 2' OF WALL SPACE. | | | | 4)NOTE: PLEASE SEE FBC 104.6.5 FOR | | INCREASE OF VALUE FOR PERMIT. PLEASE SEE | | BUILDING PLAN REVIEW COMMENTS FOR THIS. | | DUE TO INCREASE OF AREA OF BLDG TO | | INCLUDE ALL TRADES. | | | | 5)NOTE: PLEASE SEE POSSIBLE MISPRINT IN | | LOAD CALCS FOR "DETAIL UNITS". SHOULD | | READ RETAIL UNITS. THIS IS ONLY A NOTE. | | | | 6 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | NOTED ON PLANS. | | | | PLEASE REMOVE ALL OLD/VOIDED SHEETS AND | | ONLY INSERT NEW SHEETS INTO COMPLETE SET | | -S FOR REVIEW AND STAMPING. | | PLEASE SEE ONE SET HAS SOME ITEMS | | REDLINED FOR AREAS OF ABOVE COMMENTS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-02-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-02-18 |
Time |
17:06 |
Rev Time |
1.00 |
Received By |
dpalmer |
Date |
2004-02-18 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-01-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-01-07 |
Time |
16:33 |
Rev Time |
2.00 |
Received By |
dpalmer |
Date |
2004-01-07 |
Time |
16:29 |
Sent To |
|
|
Notes |
2004-01-07 00:00:00 | *********** UNSAT **************** | | | | BLDG "G" | | | | 1)NOTE: PLEASE SEE NOTE FOR MAIN AND | | SERVICE ENT CONDUCTORS. PLEASE SEE COND | | ARE RATED FOR 670A'S AND NOTHING TO | | LIMIT LOAD FOR SERVICE. OCP ADDS UP TO | | 910A'S. PLEASE SEE 230.42B | | | | PLEASE SUBMIT THE ABOVE FOR REVIEW. | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-11-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-03 |
Time |
06:45 |
Rev Time |
1.50 |
Received By |
dpalmer |
Date |
2003-11-03 |
Time |
06:45 |
Sent To |
|
|
Notes |
2003-11-03 00:00:00 | ************** UNSAT **************** | | | | 1)NOTE: PLEASE SEE THAT WE ARE NOW UNDER | | THE 2002 NEC. PLEASE ADJUST PLANS. | | | | 2)NOTE: PLEASE SEE FIRE REVIEW COMMENTS | | AND COMMENTS FROM OTHER REVIEWERS THAT | | MAY HAVE AN AFFECT ON ELECTRICAL PLANS. | | | | 3)NOTE: PLEASE SEE 210.62 FOR "SHOW " | | WINDOW RECEPTS REQ'D. | | | | 4)NOTE: PLEASE SEE 2002 NEC FOR CHANGES | | IN ARC FAULT PROTECTION. PLEASE ADJUST. | | | | 5)NOTE: PLEASE SEE 240.4C. DEVICES | | RATED OVER 800A'S. SEC'S CONDUCTORS | | MUST MEEET OR EXCEED RATING OF MAIN. | | CONDUCTORS SHOWN ARE RATED FOR A TOTAL | | OF 930A'S.310.16 | | | | 6)NOTE: PLEASE SIZE GEC TO FOOTER STEEL | | PER 250.66. PER 250.50 | | | | 7)NOTE: PLEASE SEE 700.12E FOR CIRCUIT- | | -ING OF LTS, SEEE FIRE REVIEW COMMENTS. | | | | 8)NOTE: PLEASE SHOW ALL CONTINUOUS LOADS | | AT 125%. 215.3, 230.42 ETC | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
4 |
Status |
P |
Date |
2005-12-08 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2005-12-08 |
Time |
08:19 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2005-12-08 |
Time |
08:19 |
Sent To |
|
|
Notes |
2005-12-08 00:00:00 | PASSED: | | | | 1. REVIEWED FOR THE REVISION SHEET A.1, | | SIDEWALK CONNECTING TO S. DIXIE. | | | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
3 |
Status |
P |
Date |
2004-08-25 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-08-25 |
Time |
09:55 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2004-08-25 |
Time |
09:55 |
Sent To |
|
|
Notes |
2004-08-25 00:00:00 | PASSED: | | 1. REVISION TO CIVIL/SITE PLANS DUE TO | | CHANGES / ADDITIONS SUBMITTED, SEE # | | 01031264. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
F |
Date |
2004-07-21 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2004-07-21 |
Time |
16:26 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2004-07-21 |
Time |
16:26 |
Sent To |
|
|
Notes |
2004-07-21 00:00:00 | FAILED: | | 1. MUST SUBMIT REVISIONS TO CIVIL/SITE | | PLANS DUE TO THE PROPOSED CHANGES/ | | ADDITION, PERMIT # 01031264. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
P |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
mamini |
Date |
2003-11-04 |
Time |
09:46 |
Rev Time |
0.50 |
Received By |
mamini |
Date |
2003-11-04 |
Time |
09:45 |
Sent To |
|
|
Notes |
2004-07-21 00:00:00 | PASSED: | | 1. SEE PERMIT # 01031264 FOR UNDERGROUND | | UTILITIES AND SITE WORK. | | IF ANY QUESTION PLEASE CONTACT 805-6723 | | MOHAMMAD R. AMINI |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2004-09-21 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-09-21 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-09-21 |
Time |
14:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2004-07-14 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2004-07-14 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2004-07-14 |
Time |
16:17 |
Sent To |
|
|
Notes |
2004-07-14 00:00:00 | REVISION DATED 6-22-04 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2004-02-10 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2004-02-10 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2004-02-10 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-10-31 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-10-31 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-10-31 |
Time |
15:51 |
Sent To |
|
|
Notes |
2003-10-31 00:00:00 | 1) NO FIRE SPRINKLER PLANS PROVIDED | | WITH DRAWINGS. BUILDINGS ARE REQUIRED | | TO BE FIRE SPRINKLER PROTECTED PER | | FS 553.895(2). | | | | 2) PLANS DO NOT DISPLAY ANY FIRE ALARM | | EQUIPMENT. THE REQUIRED FIRE SPRINKLER | | SYSTEM IS REQUIRED TO BE MONITORED. | | | | 3) PLEASE INDICATE PRESCRIPTIVE FOR | | HANDRAILS. | | | | 4) BUILDING ADDRESS REQUIRED ON PROPER | | ELEVATION. | | | | 5) UNIT ENTRY DOORS ARE TO BE AT LEAST | | 20 MINUTE FIRE RATED. | | | | 6) PLEASE INDICATE ON PLANS THE SINGLE | | EXIT DESIGN WITHIN THE UNITS. | | | | 7) PORTABLE FIRE EXTINGUISHERS REQUIRED. | | | | 8) NO EMERGENCY LIGHTS SHOWN FOR | | EXTERIOR STAIRS. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2005-12-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-12-05 |
Time |
11:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-12-05 |
Time |
11:28 |
Sent To |
ENG |
|
Notes |
2005-12-05 00:00:00 | TO "ENG" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2005-04-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-04-14 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-04-14 |
Time |
13:07 |
Sent To |
B |
|
Notes |
2005-04-14 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2005-03-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2005-03-28 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2005-03-28 |
Time |
14:34 |
Sent To |
B |
|
Notes |
2005-03-28 00:00:00 | TO "RBROWN" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-10-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-10-19 |
Time |
12:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-10-19 |
Time |
12:36 |
Sent To |
B |
|
Notes |
2004-10-19 00:00:00 | TO RB DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-08-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-19 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-19 |
Time |
09:14 |
Sent To |
|
|
Notes |
2004-08-19 00:00:00 | TO COMM BD#37 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2004-07-01 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-01 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-01 |
Time |
08:22 |
Sent To |
|
|
Notes |
2004-07-01 00:00:00 | TO COMM BD#38 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2004-02-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-02-09 |
Time |
11:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-02-09 |
Time |
11:48 |
Sent To |
|
|
Notes |
2004-02-09 00:00:00 | TO COMM BD#37 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-12-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-29 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-29 |
Time |
09:19 |
Sent To |
|
|
Notes |
2003-12-29 00:00:00 | TO COMM BD#53 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
P |
Date |
2005-11-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2005-11-15 |
Time |
14:58 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2005-11-15 |
Time |
14:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2004-07-15 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-07-15 |
Time |
16:39 |
Rev Time |
1.20 |
Received By |
pkrauss |
Date |
2004-07-15 |
Time |
16:24 |
Sent To |
|
|
Notes |
2004-07-15 00:00:00 | ADDITION TO EXISTING BUILDING/NOT A | | REVISION TO THE ORIGINAL SUBMITTAL |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2004-02-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-02-18 |
Time |
09:21 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2004-02-18 |
Time |
07:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2004-01-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-07 |
Time |
07:45 |
Rev Time |
0.55 |
Received By |
pkrauss |
Date |
2004-01-07 |
Time |
07:11 |
Sent To |
|
|
Notes |
2004-01-07 00:00:00 | DENIED: | | RESIDENTIAL: | | 1.PER 2001 FBC(M) 403.3, VENTILATION | | SYSTEMS, FOR OTHER THAN R-3 (ONE & TWO | | FAMILY DWELLINGS), SHALL BE DESIGNED TO | | TO SUPPLY THE MINIMUM OUTSIDE AIR IN | | ACCORDANCE WITH TABLE 403.3.PLEASE | | PROVIDE OUTSIDE AIR CALCULATIONS. | | INDICATE OUTSIED AIR DUCT SIZE, | | MATERIAL, LAYOUT AND INTAKE ON THE PLAN. | | | | 2.PLAN SHEET AC.3 INDICATES DUCT TO | | 2ND FLOOR IN RATED SHAFT. PLEASE PROVIDE | | SHAFT DETAIL. | | | | RETAIL:PLANS ARE CODE COMPLIANT. | | | | PLEASE NOTE: | | PLANS DO NOT INDICATE THE USE OF THE | | RETAIL SPACE.BECAUSE OF THE LOCATION | | AND PROPERTY LINES, ALLOWANCE FOR A | | RESTAURANT MAY BE DIFFICULT SHOULD | | CONSIDERATION NOT BE GIVEN FOR THE | | INSTALLATION OF GREASE DUCT NOT BE MADE | | AT THE BEGINNING OF CONSTRUCTION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-11-04 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-11-03 |
Time |
15:33 |
Rev Time |
2.00 |
Received By |
pkrauss |
Date |
2003-11-03 |
Time |
13:13 |
Sent To |
|
|
Notes |
2003-11-03 00:00:00 | DENIED: BUILDING G | | 1. OUTSIDE AIR REQUIRED AS PER 2001 FBC | | (M) TABLE 403.3. | | | | 2. CEILING FIRE DAMPERS REQUIRED AS | | DICTATED BY BUILDING CONSTRUCTION, SEE | | 1 HR RATED ASSEMBLY ON PLAN SHEET A.11. | | SEE ALSO DETAIL 15 ON PLAN SHEET A.15. | | PLEASE INDICATE LOCATION OF DAMPERS AS | | REQUIRED PER 2001 FBC(M) 607.6. | | | | 3. ATTIC ACCESS OPENING SHALL BE NO LESS | | THAN 30" X 22" AS PER 2001 FBC(M) 306.3 | | | | 2001 FBC CHAPTER 13 610.1.ABC.3.5.2 - | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS | | LOCATED WITHIN 6 FT OF AN ATTIC | | ACCESS. | | 2. A DEVICE IS INSTALLED TO ALERT THE | | OWNER OR SHUT DOWN WHEN THE | | CONDENSATE DRAIN IS NOT WORKING | | PROPERLY. | | 4. A NOTICE IS POSTED ON THE ELECTRIC | | SERVICE PANEL INDICATING TO THE | | HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. | | | | 4. PLAN SHEET AC.2 INDICATES TOILET | | EXHAUST AS 4" DRYER DUCT. PLEASE CLARIFY | | | | 5. PLEASE CLARIFY IF THE "DUCT SHAFTS" | | HAVE A FIRE RATING. REFERENCE PLAN | | SHEET A.11, FLOOR/CEILING ASSEMBLY. | | | | RETAIL: | | 1. FAN SHUTDOWN BY DUCT SMOKE DETECTOR | | WITH NOTIFICATION TO ALARM/STROBE AS PER | | 2001 FBC(M) 606.2.1 & NFPA 90A 4-4.4.3. | | | | 2. PLANS DO NOT INDICATE USE OF THE | | RETAIL SPACE.BECAUSE OF THE LOCATION | | AND PROPERTY LINES, ALLOWANCE FOR A | | RESTAURANT MAY BE DIFFICULT SHOULD | | CONSIDERATION NOT BE GIVEN FOR THE | | INSTALLATION OF GREASE DUCT NOT BE MADE | | AT THE BEGINNING OF CONSTRUCTION. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2004-10-12 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-10-12 |
Time |
11:39 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-10-12 |
Time |
11:39 |
Sent To |
|
|
Notes |
2004-10-12 00:00:00 | REVISIONS OK SHTS P-1, P-2, P-3, P-4, & | | P-5 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2004-09-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-09-16 |
Time |
15:13 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2004-09-16 |
Time |
15:13 |
Sent To |
|
|
Notes |
2004-09-16 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | FROM PREVIOUS REVIEW: | | 1) ALL ENGINEERED PLANS SHALL BE SIGNED | | WITH FULL SIGNATURE. FAC 61G15-23.002(1) | | (2) & FS 471.025 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2004-07-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-07-23 |
Time |
17:25 |
Rev Time |
2.00 |
Received By |
kstevens |
Date |
2004-07-23 |
Time |
17:25 |
Sent To |
|
|
Notes |
2004-07-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | FBC-2001 CHAPTER 11 | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | 1) ALL ENGINEERED PLANS SHALL BE SIGNED | | WITH FULL SIGNATURE. FAC G1G15-23.002(1) | | (2) & FS 471.025. | | 2) SHT P-3 SANT. RISER DIAGRAM, SHOW ALL | | PIPE SIZES AND DRAINAGE FIXTURE UNITS AS | | THEY ACCUMULATE IN THE BLDG. DRAIN. SEC | | 104.2.1. | | 3) SHT P-4 IF ICE MAKER LINE TO REFRIG., | | A WATER HAMMER ARRESTOR IS REQUIRED PER | | SECTION 604.9. | | 4) SUBMIT A DETAIL FOR TOILET ROOMS IN | | THE RETAIL SPACES. SHOW COMPLIANCE WITH | | SECTION 11-4.15 AND ALL SUBSECTIONS, SEC | | 11-4.1.3(10)(A) FOR THOSE WHO HAVE DIFF- | | ICULTY BENDING OR STOOPING, SECTION 11-4 | | .16 AND ALL SUBSECTIONS, 11-4.19 AND ALL | | SUBSECTIONS, & 11-4.22 AND ALL SUBSECT- | | IONS. | | 5) SUBMIT A FINISH SCHEDULE FOR TOILET | | ROOMS IN THE RETAIL SPACES. SECTION | | 104.2.1 | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2004-01-14 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-14 |
Time |
12:58 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2004-01-14 |
Time |
12:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-11-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-11-03 |
Time |
18:26 |
Rev Time |
1.00 |
Received By |
kstevens |
Date |
2003-11-03 |
Time |
18:25 |
Sent To |
|
|
Notes |
2003-11-03 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT P.1 PLUMBING NOTES #15, WATTS | | 530C NOT APPROVED FOR MULTI-HEATER USE | | PER MANUFACTURE INFORMATION. WATTS 530 | | APPROVED FOR INDIVIDUAL HEATER USE ONLY. | | PROVIDE INFORMATION FOR THERMAL EXPANS- | | ION CONTROL PER 607.3.2 ALSO SEE WATER | | RISER DIAGRAM SHT P.4 AND WATER HEATER | | DETAIL SHT P.5. | | 2) SHT P.4 WATER HAMMER ARRESTORS ARE | | REQUIRED PER SECTION 604.9 FOR WASH | | MACHINES, DISHWASHERS, AND ICE MAKERS. | | SHOW WATER HAMMER ARRESTORS ON THE WATER | | RISER LOCATED NEAR THE FIXTURES IN AN | | "EFFECTIVE RANGE" NOT IN THE CEILING. | | 3) AN RPZ BACKFLOW IS REQUIRED ON THE | | WATER SERVICE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2005-12-02 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2005-12-02 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2005-12-02 |
Time |
08:45 |
Sent To |
|
|
Notes |
2005-12-02 00:00:00 | GIVEN TO INCOMING FOR ENGINEERING REVIEW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2004-08-30 |
Time |
10:58 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2004-08-30 |
Time |
10:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2004-07-20 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2004-07-20 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2004-07-20 |
Time |
11:42 |
Sent To |
|
|
Notes |
2004-07-20 00:00:00 | 7/20/04 - FAILED. | | 1) EASEMENT RELOCATION AGREEMENT MUST BE | | RECORDED PRIOR TO ISSUANCE OF PERMIT. | | 2) LANDSCAPE PLANS MUST BE SIGNED AND | | SEALED. | | 3) PLANS MUST BE SIGNED OFF BY HISTORIC | | PRESERVATION DIVISION. | | CALL JOHN ROACH, PLANNER 659.8031 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-11-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-11-03 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2003-11-03 |
Time |
11:18 |
Sent To |
I |
|
Notes |
2003-11-03 00:00:00 | 11/3/03 OK PER ERIC SCHNEIDER MM |
|
|