Plan Review Details - Permit 03100367
Plan Review Stops For Permit 03100367
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2004-01-10 Cont ID  
Sent By shill Date 2004-01-06 Time 16:06 Rev Time 1.00
Received By shill Date 2004-01-06 Time 16:06 Sent To E
Notes
2004-01-06 00:00:00****PROVISO*****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 [email protected]
  
 SUBMIT REVISIONS FOR SHEETS 2 AND 3
 ADDRESSING PLUMBING CORRECTIONS AND
 STRUCTURAL CORRECTION, PE NUMBER
 REQUIRED ON EACH SHEET.
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-12-15 Cont ID  
Sent By kstevens Date 2004-01-06 Time 11:02 Rev Time 1.00
Received By shill Date 2003-12-15 Time 13:48 Sent To  
Notes
2003-12-15 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724
  
 1.)SEE PREVIOUS LIST, ITEM #3, ENERGY
 CALCS REQUIRED.
  
 2.)SEE PREVIOUS LIST, ITEM #4, PE
 NUMBER REQUIRED ON EACH SHEET (MISSING
 ON SHEET 2).SEALS ARE TO BE SIGNED
 WITH A SIGNATURE (NOT INITIALS AS PER
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS)
 AND A DATE, FAC61G15-23.002.
  
 3.)EFFECTIVE OCTOBER 1, 2003, EITHER
 A STATEWIDE OR SITE SPECIFIC PRODUCT
 APPROVAL IS REQUIRED.FOR MORE
 INFORMATION SEE THE DCA WEBSITE AT
 WWW.FLORIDABUILDING.ORG.PRINT THE
 STATEWIDE PRODUCT APPROVAL, IF
 AVAILABLE, SHOWING THE PRODUCT NAME AND
 APPROVAL STATUS.ANY PRODUCTS NOT
 SUBMITTED WITH A STATEWIDE OR SITE
 SPECIFIC AT TIME OF PERMIT ISSUANCE WILL
 REQUIRE A SEPARATE PERMIT.IF YOU ARE
 UNABLE TO LOCATE YOUR PRODUCT ONLINE,
 CONTACT ME FOR INSTRUCTIONS ON OBTAINING
 A SITE SPECIFIC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-10-30 Cont ID  
Sent By kstevens Date 2003-12-08 Time 11:42 Rev Time 1.50
Received By sthyng Date 2003-10-30 Time 13:06 Sent To  
Notes
2003-10-30 00:00:00****CORRECTIONS****
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)PROVIDE AREA CALCULATIONS ON THE
 PLAN; EXISTING AND NEW TOTAL.ADDITIONS
 OF OVER 25% MUST COMPLY WITH FBC3407.1.2
 2003 AMENDMENT.NOTE ON PLAN (GFCI,
 SMOKE DETECTORS).
  
 2.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY.THE PLANS MUST BE
 STAMPED AND THE RECEIPT ATTACHED TO THE
 APPLICATION.
  
 3.)ENERGY CALCS SIGNED BY BOTH THE
 PREPARER AND OWNER/AGENT REQUIRED
 FBC13-103.1.2.
  
 4.)PE LICENSE NUMBER REQUIRED ON EACH
 SHEET, FAC61G15-23.002.
  
 5.)CONFIRM THAT THE ADDITION DOES NOT
 BLOCK THE ONLY EGRESS THAT COMPLIES
 WITH FBC1005.4 FOR THE EXISTING BEDROOM.
  
 6.)SHEET 3, MTS12, A WOOD TO WOOD
 CONNECTOR IS SPECIFIED IN A WOOD TO
 MASONRY APPLICATION.ADDRESS.
  
 7.)TYPICAL WALL SECTION, SHEET 3,
 BOTTOM OF THE FOUNDATION IS REQUIRED
 TO BE A MINIMUM OF 12" BELOW GRADE,
 FBC1804.1.3.
  
 8.)CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC1804.1.7, FLOOR ELEVATION
 SHALL BE A MINIMUM OF 4" ABOVE FINISHED
 GRADE, REVISE WALL SECTION.
  
 9.)A ROOF TILE NOA WAS SUBMITTED,
 CLARIFY.
  
 10.) EFFECTIVE OCTOBER 1, 2003, EITHER A
 STATEWIDE OR LOCAL PRODUCT APPROVAL IS
 REQUIRED.FOR MORE INFORMATION, SEE
 WWW.DCA.STATE.FL.US/FHCD/FBC/COMMITTEES/
 PRODUCT_APPROVAL/1_PRODUCT_APPROVAL.HTM
  
 PRODUCT APPROVAL WILL BE REQUIRED FOR
 THE SLIDING GLASS DOOR AND IMPACT
 PROTECTION FOR THE DOOR AS WELL AS THE
 MODIFIED BITUMEN AND SINGLE HUNG WINDOW.
  
 11.) ADDITIONAL FEES DUE, $3.90, SEE
 ATTACHED BZ231392.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-10-16 Cont ID  
Sent By shill Date 2004-01-10 Time 17:38 Rev Time 0.50
Received By btrobaug Date 2003-10-16 Time 17:33 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-12-29 Cont ID  
Sent By csiegber Date 2003-12-29 Time 08:53 Rev Time 0.00
Received By csiegber Date 2003-12-29 Time 08:52 Sent To P
Notes
2003-12-29 00:00:00TO KS BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-11-21 Cont ID  
Sent By csiegber Date 2003-11-21 Time 14:20 Rev Time 0.00
Received By csiegber Date 2003-11-21 Time 14:20 Sent To P
Notes
2003-11-21 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-10-10 Time 15:50 Rev Time 0.00
Received By csiegber Date 2003-10-10 Time 15:49 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-09 Cont ID  
Sent By mmclean Date 2003-10-10 Time 12:51 Rev Time 0.00
Received By csiegber Date 2003-10-09 Time 15:02 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-10-07 Cont ID  
Sent By csiegber Date 2003-10-07 Time 09:13 Rev Time 0.00
Received By csiegber Date 2003-10-07 Time 09:13 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-10-21 Cont ID  
Sent By kstevens Date 2003-10-18 Time 08:10 Rev Time 0.25
Received By pkrauss Date 2003-10-21 Time 07:50 Sent To P
Notes
2003-10-21 00:00:00PROVISO:
 PLEASE NOTE, REVISION TO THE 2001
 FBC(M) 601.4, EFFECTIVE JUNE 30,2003:
  
 BALANCED AIR RETURN - RETURN/TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM ITS SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-01-06 Cont ID  
Sent By kstevens Date 2004-01-06 Time 11:02 Rev Time 1.00
Received By kstevens Date 2004-01-06 Time 11:02 Sent To B
Notes
2004-01-06 00:00:00PASSED/PROVISO - REVISION REQUIRED -
 SECTION 909.1

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-12-08 Cont ID  
Sent By csiegber Date 2003-12-29 Time 08:53 Rev Time 0.33
Received By kstevens Date 2003-12-08 Time 11:42 Sent To B
Notes
2003-12-08 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FLA. ADMIN. CODE
 FLA. STATUES
  
 1) SANITARY RISER DIAGRAM DOES NOT MEET
 CODE REQUIREMENTS. WASH MACHINE SHALL
 NOT DRAIN THROUGH THE WET VENT FOR THE
 BATHROOM GROUP. 909.1 - CONNECT THE W/M
 DISCHARGE LINE IN DOWNSTREAM OF THE
 BATHROOM FIXTURES. CONNECT THE WATER
 CLOSET LINE INTO THE VENT FOR THE LAV.
 2) SIGNATURE REQUIRED ON SEAL OF ENGIN-
 EER PER FAC 61G15-23.002(1) & FS 471.025
 INITIALS ARE NOT ACCEPTABLE PER FBPE &
 BLDG. OFFICIAL.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-10-18 Cont ID  
Sent By csiegber Date 2003-11-21 Time 14:20 Rev Time 0.25
Received By kstevens Date 2003-10-18 Time 08:10 Sent To M
Notes
2003-10-18 00:00:00NO PLUMBING PLANS SUBMITTED

Review Stop Z ZONING
Rev No 2 Status P Date 2003-10-10 Cont ID  
Sent By mmclean Date 2003-10-10 Time 12:51 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-10-08 Cont ID  
Sent By csiegber Date 2003-10-09 Time 15:02 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-10-08 00:00:0010/8/03 DENIED, NEED TO SHOW ADDITION
 ON SURVEY WITH SETBACKS CALLED CONTR
 FILE P MM