Plan Review Stops For Permit 03092071 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-12-23 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2003-12-23 |
Time |
11:55 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2003-12-23 |
Time |
11:55 |
Sent To |
PC |
|
Notes |
2003-12-23 00:00:00 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-11-25 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-22 |
Time |
12:35 |
Rev Time |
1.00 |
Received By |
jgomez |
Date |
2003-11-25 |
Time |
14:41 |
Sent To |
PC |
|
Notes |
2003-11-25 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1-PLANS DON'T MATCH. ELECTRICAL PLAN | | DOESN'T MATCH FLOOR PLAN. CLARIFY AS | | REQUIRED. | | 2-ENERGY CALCULATIONS DON'T MATCH FLOOR | | PLAN AREA. PLANS SHOW 1400S.F. AND | | ENERGY CALCS SHOW 1092S.F. CLARIFY | | AS REQUIRED. | | 3-PROVIDE IMPACT FEES PAID RECEIPT. | | 4-PROVIDE COMPLETE INFORMATION FOR STORM | | SHUTTERS. INSTALLATION SCHEDULE KEY | | PLAN & CLEARLY MARK ON DWGS SPECIFIC | | MOUNTING CONDITIONS AND ANCHOR TYPE | | AND SPACING TO BE USED. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | **NOTE: IF INFORMATION IS NOT COMPLETE, | | THEN, CONTRACTOR MAY APPLY FOR STORM | | SHUTTERS UNDER A SEPARATE PERMIT. | | 5-CONTRACTOR TO UPDATE INSURANCE. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-10-29 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-19 |
Time |
18:00 |
Rev Time |
2.00 |
Received By |
jgomez |
Date |
2003-10-29 |
Time |
13:26 |
Sent To |
PC |
|
Notes |
2003-10-29 00:00:00 | BUILDING CHECKLIST: | | 1-PLANS DON'T MATCH. PLANS SUBMITTED ARE | | FOR 2 DIFFERENT MODELS. | | 2-NEED LETTER CERTIFICATE FROM THE THIRD | | PARTY AGENCY AS REQ'D BY SEC. 428.4.2 | | FBC 2001. | | 3-PAY IMPACT FEES TO PALM BEACH COUNTY. | | BRING BACK STAMPED DRAWINGS & RECEIPT. | | 4-SURVEY NEEDS ORIGINAL SIGNATURE, DATE | | AS REQ'D BY CHAPTER 471 FL STATUTES. | | 5-ENERGY CALCULATIONS: A)COMPLETE ALL | | INFO. ON TOP OF FORM. | | B)CLARIFY WHY THERE IS NOT INSULATION ON | | THE RAISED FLOOR . SECTION 605 CHAPTER | | 13 FBC 2001. | | C)REVISE/CLARIFY VALUE GIVEN FOR UNDER | | ATTIC INSULATION. SEE PLANS FOR RVALUE | | USED. | | D)PREPARER TO SIGN AND DATE BOTTOM OF | | FORM. SEC. 103.1.1 CHAPTER 13 FBC. | | E)OWNER/AGENT TO SIGN AND DATE BOTTOM OF | | FORM. SEC. 103.1.2 CHAPTER 13 FBC 2001 | | | | 6-LOCAL ENGINEER TO PROVIDE ALL INFO. AS | | LISTED ON SEC. 1606.1.7 FBC 2001. | | 7-LOCAL ENGINEER TO PROVIDE ALL HIS INFO | | AS REQ'D BY CHAPTER 471 FL. STATUTES. | | 8-STORM SHUTTERS: A)PROVIDE LEGIBLE AND | | COMPLETE DRAWINGS. PAGE ONE AND TWO. | | B)PROVIDE KEY PLAN AND COMPLETE INSTALLA | | TION SCHEDULE. | | C)CLEARLY MARK ON STORM SHUTTER DRAWINGS | | SPECIFIC MOUNTING CONDITIONS & ANCHOR | | TYPE AND SPACING TO BE USED ACCORDING | | TO THE DESIGN PRESSURES, PANEL SPAN, | | EDGE DISTANCE, CONNECTION TYPE AND | | STRUCTURE TO BE ATTACHED TO. SECTION | | 104.2.1.2 CITY AMENDMENTS TO FBC 2001. | | | | 9-SOIL TEST REPORT TO HAVE ORIGINAL | | SIGNATURE AS REQUIRED BY CHAPTER 471 | | FLORIDA STATUTES. | | 10-CONTRACTOR'S SCREEN CALLS FOR EXPIRED | | INSURANCE. PLEASE, UPDATE CONTRACTOR'S | | INFORMATION WITH PERMIT CLERK. | | 11-OWES $171.51 FOR UPDATED VALUE AND | | RADON FEES. PLEASE PAY ATTACHED | | RECEIPT. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | JULIO GOMEZ AT 805-6712. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-12-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-22 |
Time |
12:35 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-12-22 |
Time |
12:28 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-11-19 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-11-19 |
Time |
18:00 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-11-19 |
Time |
13:14 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-10-20 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-18 |
Time |
16:53 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-10-20 |
Time |
15:51 |
Sent To |
M |
|
Notes |
2003-10-20 00:00:00 | ************ UNSAT ************** | | | | 1)NOTE: PLEASE SEE PLANS REFERENCE 1999 | | NEC, AS OF 7/1/2003 WE ARE NOW UNDER | | THE 2002 NEC. | | | | 2)NOTE: PLEASE LIST THE REQ'D ARC FAULT | | PROTECTED CIRCUITS PER 210.12. | | PLEASE SEE THAT IS IT NO LONGER JUST | | RECEPTS. | | | | 3)NOTE: PLEASE SUBMIT A RISER DIAGRAM | | COMPLETE WITH CONDUCTORS/CONDUITS AND | | LOAD CALCULATIONS FOR MIN REQ'D PER | | NEC 220. 215.5MIN LOADS PER NEC 220 | | | | 4)NOTE: PLEASE SHOW GROUNDING ELECTRODE | | SYSTEM PER 250.50. | | | | 5)NOTE: PLEASE CLARIFY REQ'D SD'S PER | | NFPA-72 2-5. PLEASE SEE THAT PLANS SHOW | | WHAT APPEAR TO BE TELEPHONE OUTLETS | | AT LOCATIONS FOR SD'S? | | | | 6)NOTE: PLEASE SHOW A/C UNITS AND RECEPT | | -S PER 210.63. | | | | 7)NOTE: PLEASE SEE MISSING RECEPT FOR | | 2' OF WALL SPACE PER 210.52. BR#3 | | | | 8)NOTE: PLEASE SEE FS 471.025 AND FAC | | 61G15-23.002. PLANS ARE REQ'D TO BE | | ORIGINAL SIGNATURE,DATED AND SEALED BY | | ENGINEER OF RECORD. THIS COMMENT IS | | FOR ALL PAGES INCLUSIVE OF OTHER TRADES | | ALSO,WEATHER OR NOT IT IS ANOTHER REVIEW | | -ERS COMMENTS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-11-18 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-18 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-18 |
Time |
16:52 |
Sent To |
E |
|
Notes |
2003-11-18 00:00:00 | TO BT DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-10-07 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-10-09 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-10-07 |
Time |
14:32 |
Sent To |
Z |
|
Notes |
2003-10-07 00:00:00 | CONTR HIGHLIGHTED LANDSCAPE PLAN FOR | | ZONING, SENT TO ZONING.SH |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-10-03 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-01 |
Time |
09:54 |
Sent To |
|
|
Notes |
2003-10-09 00:00:00 | 10/09/2003 TO SFD RACK/E | 2003-10-06 00:00:00 | TO SFD RACK/E | 2003-10-01 00:00:00 | TO Z |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-20 |
Time |
15:51 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2003-10-22 |
Time |
07:50 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-10-14 |
Time |
16:42 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-10-14 |
Time |
16:42 |
Sent To |
E |
|
Notes |
2003-10-14 00:00:00 | PREFAB HOUSE NO PLUMBING PLAN REVIEW. | | WATER AND SEWER HOOK-UP ONLY |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2003-10-09 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-10-09 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
2003-10-09 00:00:00 | 10/9/03 PASS PER ANGELLA JONES-VANN MM |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2003-10-03 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-10-07 |
Time |
14:32 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
2003-10-03 00:00:00 | 10/3/03 DENIED, NEED LANDSCAPE PLAN 1 | | SHADED TREE FOR EACH 1200SQ FT OF OPEN | | SPACE & 1 SCRUB FOR 500SQ FT OF OPEN | | SPACE CALLED CONTRACTOR PASS ON PLANS | | TO OTHER REVIEWERS MM |
|
|