Plan Review Details - Permit 03091932
Plan Review Stops For Permit 03091932 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-10-22 |
Time |
13:37 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-10-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-22 |
Time |
11:15 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2003-10-16 |
Time |
14:04 |
Sent To |
|
|
Notes |
2003-10-16 00:00:00 | ****************BUILDING*************** | | | | 1. IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY AND A COPY OF THE RECEIPT | | SUBMITTED & PLANS STAMPED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2. A RECORDED NOTICE OF COMMENCEMENT | | MUST BE SUBMITTED BEFORE A PERMIT CAN | | BE ISSUED. | | | | 3. A INSTALLATION SCHEDULE AND KEY PLAN | | FOR THE HURRICANE PANELS MUST BE | | SUBMITTED. | | | | 4. A COPY OF THE STAIR DETAILS APPROVED | | BY THE ARCHITECT MUST BE SUBMITTED | | BEFORE INSTALLATION PER ARCHITECT NOTE | | ON PLANS. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-10-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-10-08 |
Time |
17:47 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-14 |
Time |
16:04 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-22 |
Time |
11:15 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-22 |
Time |
11:15 |
Sent To |
B |
|
Notes |
2003-10-22 00:00:00 | TO LS DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-03 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-03 |
Time |
11:36 |
Sent To |
E |
|
Notes |
2003-10-03 00:00:00 | TO SFD RACK/E |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-09-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-10-02 |
Time |
15:29 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-29 |
Time |
11:05 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-10-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-14 |
Time |
16:05 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-10-16 |
Time |
09:03 |
Sent To |
B |
|
Notes |
2003-10-16 00:00:00 | PROVISO: | | PLEASE NOTE, REVISION TO THE 2001 | | FBC(M) 601.4, EFFECTIVE JUNE 30,2003: | | | | BALANCED AIR RETURN - RETURN/TRANSFER | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM ITS SERVING & THE | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-10-08 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-10-08 |
Time |
17:47 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-10-08 |
Time |
17:46 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-10-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-29 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
|