Plan Review Details - Permit 03090320
Plan Review Stops For Permit 03090320 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-20 |
Time |
07:50 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2003-10-23 |
Time |
11:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-10-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-28 |
Time |
14:58 |
Rev Time |
0.75 |
Received By |
lsmith |
Date |
2003-10-07 |
Time |
08:44 |
Sent To |
|
|
Notes |
2003-10-07 00:00:00 | *********BUILDING PROVISO*************** | | | | 1. PLANS MUST BE TAKEN TO PALM BEACH | | COUNTY AND IMPACT FEES PAID.SUBMIT | | PAID RECEIPT BEFORE PERMIT CAN BE | | ISSUED. | | 2. A NOTICE OF COMMENCEMENT MUST BE | | FILED AT THE COUNTY CLERKS OFFICE AND A | | COPY SUBMITTED TO THE CITY. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-10-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-20 |
Time |
07:49 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-20 |
Time |
07:47 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-09-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-14 |
Time |
16:14 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-09-15 |
Time |
11:38 |
Sent To |
P |
|
Notes |
2003-09-15 00:00:00 | **************** UNSAT ***************** | | | | 1)NOTE: PLEASE SEE OCP PROTECTION SHOWN | | FOR RANGE. SHOWS 10KW W/ 40OCP? PLEASE | | SEE MIN LOAD IS 42A'S WHICH IS OVER THE | | 40A OCP. | | | | 2)NOTE: PLEASE SEE 210.52C3,4 FOR GFI | | RECEPT MISSING ON PENINSULAR. SEPARATE | | SPACES. | | | | 3)NOTE: PLEASE SEE MISSING RECEPT PER | | 210.52 FOR 2' OF WALL. | | | | 4)NOTE: PLEASE CLARIFY OCP SHOWN FOR | | 10KW HEAT FOR AHU. SHOWN AS 2P-50A, | | PLEASE SEE 424.3B FOR 125% MIN OCP. | | | | 5)NOTE: NEW MASTER BEDROOM, LIST ARC | | FAULT PROTECTION AS REQD' PER 210.12 | | OF NEC. | | | | 6)NOTE: PLEASE SEE NFPA-72, SD @ KITCHEN | | TO BE A MIN OF 3' FROM KITCHEN AREA. | | CAN BE MOVED OVER OR NOTED TO BE 3'. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-14 |
Time |
16:14 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-14 |
Time |
16:14 |
Sent To |
E |
|
Notes |
2003-10-14 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-09-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-10 |
Time |
14:45 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-10 |
Time |
14:45 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-09-08 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-09-10 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-08 |
Time |
12:03 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2003-09-28 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-24 |
Time |
13:42 |
Rev Time |
0.15 |
Received By |
pkrauss |
Date |
2003-09-28 |
Time |
14:57 |
Sent To |
B |
|
Notes |
2003-09-28 00:00:00 | NO MECHANICAL PLANS SUBMITTED FOR | | REVIEW.PLEASE PROVIDE INFORMATION ON | | EXISTING A/C EQUIPMENT INDICATED ON | | FORM 600C.PROVIDE MAKE MODEL & BTU OF | | THE AHU.INDICATE NEW DUCTWORK SHOWING | | MATERIAL, SIZE OF DUCT AND GRILLES. | | INDICATE RETURN AIR. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-09-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-15 |
Time |
11:38 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-09-24 |
Time |
13:41 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-09-10 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-08 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy