Plan Review Details - Permit 03090320
Plan Review Stops For Permit 03090320
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-23 Cont ID  
Sent By dpalmer Date 2003-10-20 Time 07:50 Rev Time 0.50
Received By lsmith Date 2003-10-23 Time 11:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-10-07 Cont ID  
Sent By pkrauss Date 2003-09-28 Time 14:58 Rev Time 0.75
Received By lsmith Date 2003-10-07 Time 08:44 Sent To  
Notes
2003-10-07 00:00:00*********BUILDING PROVISO***************
  
 1. PLANS MUST BE TAKEN TO PALM BEACH
 COUNTY AND IMPACT FEES PAID.SUBMIT
 PAID RECEIPT BEFORE PERMIT CAN BE
 ISSUED.
 2. A NOTICE OF COMMENCEMENT MUST BE
 FILED AT THE COUNTY CLERKS OFFICE AND A
 COPY SUBMITTED TO THE CITY.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-20 Cont ID  
Sent By dpalmer Date 2003-10-20 Time 07:49 Rev Time 0.33
Received By dpalmer Date 2003-10-20 Time 07:47 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-09-15 Cont ID  
Sent By csiegber Date 2003-10-14 Time 16:14 Rev Time 0.75
Received By dpalmer Date 2003-09-15 Time 11:38 Sent To P
Notes
2003-09-15 00:00:00**************** UNSAT *****************
  
 1)NOTE: PLEASE SEE OCP PROTECTION SHOWN
 FOR RANGE. SHOWS 10KW W/ 40OCP? PLEASE
 SEE MIN LOAD IS 42A'S WHICH IS OVER THE
 40A OCP.
  
 2)NOTE: PLEASE SEE 210.52C3,4 FOR GFI
 RECEPT MISSING ON PENINSULAR. SEPARATE
 SPACES.
  
 3)NOTE: PLEASE SEE MISSING RECEPT PER
 210.52 FOR 2' OF WALL.
  
 4)NOTE: PLEASE CLARIFY OCP SHOWN FOR
 10KW HEAT FOR AHU. SHOWN AS 2P-50A,
 PLEASE SEE 424.3B FOR 125% MIN OCP.
  
 5)NOTE: NEW MASTER BEDROOM, LIST ARC
 FAULT PROTECTION AS REQD' PER 210.12
 OF NEC.
  
 6)NOTE: PLEASE SEE NFPA-72, SD @ KITCHEN
 TO BE A MIN OF 3' FROM KITCHEN AREA.
 CAN BE MOVED OVER OR NOTED TO BE 3'.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-14 Cont ID  
Sent By csiegber Date 2003-10-14 Time 16:14 Rev Time 0.00
Received By csiegber Date 2003-10-14 Time 16:14 Sent To E
Notes
2003-10-14 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-10 Cont ID  
Sent By csiegber Date 2003-09-10 Time 14:45 Rev Time 0.00
Received By csiegber Date 2003-09-10 Time 14:45 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-09-08 Cont ID  
Sent By mmclean Date 2003-09-10 Time 10:42 Rev Time 0.00
Received By csiegber Date 2003-09-08 Time 12:03 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-09-28 Cont ID  
Sent By kstevens Date 2003-09-24 Time 13:42 Rev Time 0.15
Received By pkrauss Date 2003-09-28 Time 14:57 Sent To B
Notes
2003-09-28 00:00:00NO MECHANICAL PLANS SUBMITTED FOR
 REVIEW.PLEASE PROVIDE INFORMATION ON
 EXISTING A/C EQUIPMENT INDICATED ON
 FORM 600C.PROVIDE MAKE MODEL & BTU OF
 THE AHU.INDICATE NEW DUCTWORK SHOWING
 MATERIAL, SIZE OF DUCT AND GRILLES.
 INDICATE RETURN AIR.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-09-24 Cont ID  
Sent By dpalmer Date 2003-09-15 Time 11:38 Rev Time 0.33
Received By kstevens Date 2003-09-24 Time 13:41 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-09-10 Cont ID  
Sent By csiegber Date 2003-09-08 Time 12:03 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***