Plan Review Details - Permit 03081832
Plan Review Stops For Permit 03081832
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-30 Cont ID  
Sent By hpiskura Date 2003-10-30 Time 07:45 Rev Time 0.00
Received By hpiskura Date 2003-10-30 Time 07:45 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-10-02 Cont ID  
Sent By hpiskura Date 2003-10-02 Time 14:24 Rev Time 0.00
Received By hpiskura Date 2003-10-02 Time 14:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-24 Cont ID  
Sent By dpalmer Date 2003-10-24 Time 06:36 Rev Time 0.50
Received By dpalmer Date 2003-10-24 Time 06:33 Sent To  
Notes
2003-10-24 00:00:00OLD/VOIDED SHEETS SHOULD HAVE BEEN
 REMOVED AND ONLY NEW SHEETS SHOULD BE
 IN NEW SETS.
 ELEC SHEETS STAMPED.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-09-09 Cont ID  
Sent By dbaxter Date 2003-08-29 Time 15:35 Rev Time 1.00
Received By dpalmer Date 2003-09-09 Time 07:48 Sent To  
Notes
2003-09-09 00:00:00************ NOTES *****************
  
 1)NOTE: PLEASE VERIFY AIC RATING FOR
 NEW DISC'C FOR A,B,C PANELS.
 NOTE "N" MENTIONS 65K RATING? IS THIS
 FOR NEW MAINS?
 110.9/215.5
  
 2)NOTE: PLEASE CLARIFY LOCATION OF
 BARRRIER SHOWN TO BE INSTALLED IN GUTTER
 IT APPEARS PANEL "C" WILL BE FED FROM
 MAIN 1OF 3 AND PANELS A & B WILL BE FED
 FROMMAIN 2 OF 3?
  
 PLEASE SEE FIRE REVIEW COMMENTS FOR ANY
 POSSIBLE CHANGES TO ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-09-09 Cont ID  
Sent By nmccray Date 2003-09-09 Time 09:54 Rev Time 0.00
Received By nmccray Date 2003-09-09 Time 09:53 Sent To  
Notes
2003-09-09 00:00:00**************PROVISO*******************
 ADDITIONAL SHOP DRAWINGS AND PERMITS ARE
 REQUIRED FOR FIRE SPRINKLER AND FIRE
 ALARM SYSTEMS REMODEL.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-10-15 Cont ID  
Sent By csiegber Date 2003-10-15 Time 12:12 Rev Time 0.00
Received By csiegber Date 2003-10-15 Time 12:12 Sent To  
Notes
2003-10-15 00:00:00TO COMM BD#28

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-29 Cont ID  
Sent By dbaxter Date 2003-08-29 Time 15:34 Rev Time 0.00
Received By dbaxter Date 2003-08-29 Time 15:34 Sent To E
Notes
2003-09-09 00:00:00DID NOT SEND TO ELEC.
 PLACED ON COMM BOARD.
2003-08-29 00:00:00TO COMM. BD. #58.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-29 Cont ID  
Sent By pkrauss Date 2003-09-29 Time 07:29 Rev Time 1.00
Received By pkrauss Date 2003-09-29 Time 07:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-10-31 Cont ID  
Sent By kstevens Date 2003-10-31 Time 09:06 Rev Time 1.00
Received By kstevens Date 2003-10-31 Time 09:06 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-10-02 Cont ID  
Sent By kstevens Date 2003-10-02 Time 12:20 Rev Time 1.00
Received By kstevens Date 2003-10-02 Time 12:20 Sent To  
Notes
2003-10-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 NEC-2002
  
 1) RPZ BACKFLOW REQUIRED
 2) THERMAL EXPANSION PROTECTION REQUIRED
 SECTION 607.3.2
 3) A DRINKING FOUNTAIN IS REQUIRED PER
 TABLE 403.1. (ALSO SEE SECTION 410.1)
 4) EACH ELECTRICALLY HEATED APPLIANCE
 THAT IS INTENDED BY SIZE, WEIGHT, AND
 SERVICE TO BE LOCATED IN A FIXED POSIT-
 ION SHALL BE PLACED SO AS TO PROVIDE
 AMPLE PROTECTION BETWEEN THE APPLIANCE
 AND ADJACENT COMBUSTIBLE MATERIAL. SEC
 422-17. - WATER HEATERS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]