Plan Review Details - Permit 03081726
Plan Review Stops For Permit 03081726
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-10-10 Cont ID  
Sent By csiegber Date 2003-11-12 Time 11:14 Rev Time 0.00
Received By hpiskura Date 2003-10-10 Time 16:13 Sent To  
Notes
2003-10-10 00:00:00PROVISO:PROVIDE ENGINEERED DRAWINGS
 FOR THE DELEGATED DESIGN ITEMS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-12 Cont ID  
Sent By hpiskura Date 2003-09-12 Time 12:11 Rev Time 0.00
Received By hpiskura Date 2003-09-12 Time 12:11 Sent To  
Notes
2003-09-12 00:00:00THIS BUILDING IS LOCATED IN THE
 DESIGNATED FIRE DISTRICT.TYPE VI
 CONSTRUCTION,(IE WOOD FRAME) IS NOT
 PERMITTED.SOME OF THE EXTERIOR
 ARCHITECTURAL FEATURES PROPOSED SHOW
 WOOD STUDS AND WALL SHEATHING.PLEASE
 REVISE AS NECESSARY.SEE FBC F102.1 AS
 AMENDED BY THE CITY OF WEST PALM BEACH.
  
 ARCHITECTURAL TRIM IS REQUIRED TO BE
 NON-COMBUSTIBLE OR FRT WOOD. SEE FBC
 F102.2.7.IS THE FYPON MATERIAL
 NON-COMBUSTIBLE AS DEFINED IN FBC 202.
  
 PLEASE PROVIDE SPECIFIC CONSTRUCTION
 DETAILS FOR THE SUSPENDED DRYWALL AND
 PANELCEILINGS.INCLUDE FASTENERS,
 MATERIALS AND CONNECTION METHODS. FBC
 104.2.
  
 THE VARIOUS SECURITY GATES SHOWN MUST
 COMPLY WITH FBC 1020.3 AND 1012.1.7.
  
 THE REQUIRED EXTERIOR EGRESS DOORS MUST
 COMPLY WITH FBC 1012.5 SWING OVER PUBLIC
 ROW, 1003.2.3 CLEAR WIDTH,
 PARTICULARLY SINGLE LEAF OF DOUBLE
 DOOR,SEE ALSO FBC 11-4.13.
  
 THE NOTES AND SPECIFICATIONS PAGES ARE
 RECOGNIZED TO THE EXTENT THAT THEY ARE
 NOT IN CONFLICT WITH THE FBC 2001 WITH
 6/03 REVISIONS AND STANDARDS AND
 REFERENCES OF THE FBC.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-10-09 Cont ID  
Sent By dpalmer Date 2003-10-09 Time 15:11 Rev Time 1.00
Received By dpalmer Date 2003-10-09 Time 15:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-09-15 Cont ID  
Sent By dpalmer Date 2003-09-15 Time 17:24 Rev Time 1.50
Received By dpalmer Date 2003-09-15 Time 17:00 Sent To  
Notes
2003-09-15 00:00:00********** UNSAT ************
  
 PLEASE SEE COMMENTS FROM OTHER REVIEWERS
 THAT MAY HAVE AN AFFECT ON ELECTRICAL
 PLANS.
  
 1)NOTE: PLEASE SEE COPY OF FAC ATTACHED,
 61G15-23.002 FOR ALL INFORMATION REQ'D
 ON TITLE BLOCK FOR ENGINEERS AND FAC
 61G1-16.004 FOR ARCH'S.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2003-10-17 Cont ID  
Sent By lmartine Date 2003-10-17 Time 16:15 Rev Time 0.00
Received By mcarsill Date 2003-10-17 Time 17:47 Sent To  
Notes
2003-10-17 00:00:00APPROVED BY MIKE CARSILLO 10/17/03LM
 SEE PLANS FOR SIGNATURE

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2003-10-09 Cont ID  
Sent By csiegber Date 2003-10-16 Time 16:35 Rev Time 0.00
Received By mcarsill Date 2003-10-09 Time 17:38 Sent To  
Notes
2003-10-09 00:00:001) IT APPEARS THAT THE ONLY PREVIOUS
 COMMENT THAT WAS ADDRESSED WAS THE
 KNOX-BOX. PLEASE ANSWER THE REMAINING
 COMMENTS.
  
 MIKE CARSILLO, ASSISTANT FIRE MARSHAL
 835-2910

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2003-09-10 Cont ID  
Sent By nmccray Date 2003-09-10 Time 12:56 Rev Time 0.00
Received By nmccray Date 2003-09-10 Time 12:56 Sent To  
Notes
2003-09-10 00:00:001) THE PLANS INDICATE A SINGLE TENANT
 OCCUPANY, HOWEVER THE BEAUTY SALON AND
 THE OUTPATIENT CLINIC APPEAR TO FUNCTION
 INDEPENDENTLY OF ONE ANOTHER. PLEASE
 ADVISE THE RELATIONSHIP AND FUNCTION OF
 THE TWO SPACES.
  
 2) HOW WILL THESE WROUGHT IRON SECURITY
 GATES BE USED DOING BUSINESS HOURS.
  
 3) PLEASE REF NFPA 101 LIFE SAFETY CODE
 2000 EDITION.
  
 4) KNOX-BOX WILL BE REQUIRED FOR FIRE
 DEPT ACCESS AFTER BUSINESS HOURS.
  
 5) WHAT IS THE INTERIOR FINISH
 CLASSIFICATION FOR THE WALLS.
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2004-03-25 Cont ID  
Sent By csiegber Date 2004-03-25 Time 15:20 Rev Time 0.00
Received By csiegber Date 2004-03-25 Time 15:19 Sent To M
Notes
2004-03-25 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-11-12 Cont ID  
Sent By csiegber Date 2003-11-12 Time 11:14 Rev Time 0.00
Received By csiegber Date 2003-11-12 Time 11:14 Sent To B
Notes
2003-11-12 00:00:00TO HP DESK/PACKET W/4 SM ROLLS

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-10-16 Cont ID  
Sent By csiegber Date 2003-10-16 Time 16:35 Rev Time 0.00
Received By csiegber Date 2003-10-16 Time 16:35 Sent To FIRE
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-10-16 Cont ID  
Sent By csiegber Date 2003-10-16 Time 16:33 Rev Time 0.00
Received By csiegber Date 2003-10-16 Time 16:33 Sent To P
Notes
2003-10-16 00:00:00TO KS BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-01 Cont ID  
Sent By csiegber Date 2003-10-01 Time 10:42 Rev Time 0.00
Received By csiegber Date 2003-10-01 Time 10:42 Sent To  
Notes
2003-10-01 00:00:00TO COMM BD#34

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-05 Cont ID  
Sent By csiegber Date 2003-09-05 Time 11:59 Rev Time 0.00
Received By csiegber Date 2003-09-05 Time 11:59 Sent To  
Notes
2003-09-05 00:00:00ON COMM BD #27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-29 Cont ID  
Sent By csiegber Date 2003-08-29 Time 10:08 Rev Time 0.00
Received By csiegber Date 2003-08-29 Time 10:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2004-04-02 Cont ID  
Sent By pkrauss Date 2004-04-02 Time 15:57 Rev Time 0.40
Received By pkrauss Date 2004-04-02 Time 15:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-10-17 Cont ID  
Sent By csiegber Date 2004-03-25 Time 15:20 Rev Time 0.45
Received By pkrauss Date 2003-10-17 Time 06:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-09-23 Cont ID  
Sent By hmoser Date 2003-09-23 Time 19:05 Rev Time 2.50
Received By hmoser Date 2003-09-23 Time 19:04 Sent To  
Notes
2003-09-23 00:00:00PLAN DENIED
 1) REFER TO SECTION 601.4 FBC.(M)
 BALANCED RETURN AIR
 2) PLEASE SUPPLY CALCULATIONS FOR FRESH
 AIR
 PLAN REVIEW BY HAROLD MOSER
 (561)805-6732

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-10-17 Cont ID  
Sent By kstevens Date 2003-10-17 Time 15:55 Rev Time 1.00
Received By kstevens Date 2003-10-17 Time 15:55 Sent To  
Notes
2003-10-17 00:00:00PASSED/PROVISO
  
 SIGNED SEALED 8-1/2" X 11" ACCESSIBLE
 BREAKROOM SINK DETAIL REQUIRED.
  
  
  
  
  
 GAS INFORMATION REQUIRED FOR GAS LIGHTS
 AT TIME OF GAS PERMIT APPLICATION

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-10-15 Cont ID  
Sent By csiegber Date 2003-10-16 Time 16:33 Rev Time 1.50
Received By kstevens Date 2003-10-15 Time 16:16 Sent To  
Notes
2003-10-15 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER-11
  
 1) FROM PREVIOUS REVIEW: SHT A.5.3, DE-
 TAIL #6, BREAKROOM SINK SHALL COMPLY
 WITH SECTION 11-4.24 AND ALL SUBSECTIONS
 PROVIDE DETAILS, SHOW CLEAR FLOOR SPACE,
 HEIGHT & CLEARANCES, FAUCETS, PIPES AND
 SURFACES, ECT.
 2) FROM PREVIOUS REVIEW: FOR GAS REVIEW,
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 E. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 3) SHT P3 PLUMBING SPECS #7, AIR CHAMB-
 ERS NOT APPROVED. DELETE REFERENCE.
 4) SHT P5 WATER RISER DIAGRAM, AIR CHAM-
 BERS NOT APPROVED. SEC 604.9 IF WATER
 HAMMER ARRESTORS THEY SHALL BE LOCATED
 NEAR THE FIXTURE, NOT IN THE CEILING.
 PDI-WH 201 AND MANUF. INSTALLATION IN-
 STRUCTIONS.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-25 Cont ID  
Sent By kstevens Date 2003-09-25 Time 12:44 Rev Time 2.00
Received By kstevens Date 2003-09-25 Time 12:44 Sent To  
Notes
2003-09-25 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 FUEL GAS
 FBC-2001 CHAPTER 1
 FBC-2001 CHAPTER 11
 FLORIDA ADMINISTRATIVE CODE
 W.P.B. CITY CODE
  
 1) SHT A.5.3 DETAIL 7, SINK SHALL COMPLY
 WITH 11-4.24 AND ALL SUBSECTIONS. PROVI-
 DE DETAILS, SHOW CLEAR FLOOR SPACE,
 HEIGHT & CLEARANCES, FAUCETS, PIPES AND
 SURFACES, ECT.
 2) CERTIFICATE OF AUTHORIZATION REQUIRED
 ON EACH SHEET. SEE ATTACHED SHEET.
 61G15-23.002(2) - ALSO ENGINEER SHALL
 LEGIBLY INDICATE THEIR NAME AND LICENSE
 NUMBER ON EACH SHEET.
 2) A RPZ BACKFLOW IS REQUIRED. 608.13.2.
 3) SUBMIT CALCULATIONS FOR PRIMARY AND
 SECONDARY ROOF DRAINS PER SECTIONS 1106
 & 1107 AND ALL SUBSECTIONS. (NEW ROOFS &
 PARAPETS) SHOW 1/2 AREA OF ALL VERTICAL
 WALLS AND ALL AREAS OF ROOFS THAT DRAIN
 ONTO THE ROOF FROM ABOVE ADDED TO CALCU-
 LATIONS. PROVIDE A ROOF PLAN TO SHOW
 LOCATIONS OF PRIMARY & SECONDARY ROOF
 DRAINS. SHOW SIZE OF DRAINS, AND IF
 SCUPPERS ARE USED PROVIDE A DETAIL SHOW-
 ING WIDTH AND HEIGHT OF OPENING ECT. PER
 SECTION 1511.6.4.3 AND SECTION 1107.
 4) DRESSING ROOM BENCH TO BE FIXED TO
 THE WALL ALONG THE LONGER DIMENSION, 17"
 TO 19" ABOVE FINISHED FLOOR. SECTION
 11-4.35.4
 5) THE FOLLOWING INFORMATION REQUIRED
 FOR GAS PERMIT. SEPARAGE GAS PERMIT REQ-
 UIRED.
 A. SUBMIT AN ISOMETRIC DRAWING THAT
 CLEARLY SHOWS ALL CUT SECTIONS OF PIPE
 AND CORRESPONDING LENGTHS PER FBC-2001
 FUEL GAS CODE.
 B. SHOW TYPE OF PIPING MATERIAL BEING
 INSTALLED, ALL PIPE SIZES, (AND THE EDH
 NUMBER OF CORRUGATED STAINLESS STEEL
 TUBING FOR EACH PIPE SIZE BEING USED.
 FBC-2001 FUEL GAS 402.3
 C. TYPE OF GAS, (LP OR NATURAL)
 D. BTU LOAD OF EACH APPLIANCE AND THE
 TOTAL BTU LOAD ON THE SYSTEM. REFER TO
 THE FBC-2001 FUEL GAS CODE SECS. 401.8
 THRU 402.5.2 AND TABLES 402(1) THRU
 402(34).
 E. INDICATE THE DELIVERY PRESSURE (PSI)
 PER FBC-2001 FUEL GAS CODE SEC. 402.2.
 NATURAL GAS SPECIFY .5 PSI OR 2 PSI.
 F. SHOW THE DISTANCE FROM THE POINT OF
 DELIVERY, (METER), TO THE MOST REMOTE
 OUTLET IN THE BUILDING AND/OR SYSTEM PER
 FBC-2001 FUEL GAS CODE APPENDIX A - USE
 OF CAPACITY TABLES (A)(3).
 G. SUBMIT MANUFACTURE SHEETS FOR ALL GAS
 EQUIPMENT TO VERIFY COMPLIANCE WITH
 STANDARDS NFPA 54, NFPA 58, AND THE
 FBC-2001 FUEL GAS CODE SEC 402.2
 H. CLEARLY SHOW THE LOCATION AND CAP-
 ACITY OF LP TANK(S), TYPE OF TANK (DOT
 OR ASME), THE DISTANCE OF THE TANK FROM
 THE BUILDING AND ADJACENT PROPERTY LINES
 THE DISTANCE OF THE TANK FROM ALL SOUR-
 CES OF IGNITION, OTHER CONTAINERS, BUILD
 INGS, AND THE LOCATION OF ANY BUILDING
 OPENINGS BELOW THE RELIEF VALVE OF THE
 TANK PER NFPA 58, TABLE 3-2.2.2.
 J. CLEARLY INDICATE ON THE PLAN IF THE
 LP TANK IS ABOVE OR BELOW GROUND, AND
 SHOW REQUIRED PROTECTION OF THE TANK AND
 APPURTENANCES PER NFPA 58. IF THE TANK
 IS BELOW GROUND THE CONTAINER SHALL BE
 SECURILY ANCHORED PER NFPA 58 SECTION
 3-2.2.7(H).
 6) GREASE INTERCEPTOR THAT IS BEING
 ABANDONED SHALL BE CLEANED OUT, AND RE-
 MOVED ENTIRELY, OR CLEANED OUT, THE TOP
 REMOVED, THE BOTTOM BUSTED UP AND FILLED
 WITH CLEAN FILL. BOTH LINES INTO AND OUT
 OF THE GREASE INTERCEPTOR SHALL BE CAPP-
 ED AND INSPECTED PRIOR TO COVERING.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status N Date 2003-09-15 Cont ID  
Sent By mmclean Date 2003-09-15 Time 08:30 Rev Time 0.00
Received By mmclean Date   Time   Sent To  
Notes
2003-09-15 00:00:009/15/03 NO ZONING REVIEW REQUIRED FOR
 INTERIOR WORK/NO CHANGES TO BUILDING