Plan Review Stops For Permit 03081472 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-09-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-16 |
Time |
14:28 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2003-09-09 |
Time |
11:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-16 |
Time |
14:28 |
Rev Time |
0.25 |
Received By |
btrobaug |
Date |
2003-12-16 |
Time |
14:28 |
Sent To |
B |
|
Notes |
2003-12-16 00:00:00 | RESTAMP./WRT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-16 |
Time |
13:38 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-10-10 |
Time |
14:31 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-09-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-09 |
Time |
09:52 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-09-19 |
Time |
06:20 |
Sent To |
P |
|
Notes |
2003-09-19 00:00:00 | ************ UNSAT *************** | | | | 1)NOTE: PLEASE SEE THAT AN ELECTRICAL | | HEAT PUMP IS STILL SHOWN ON RISER AND | | PLAN INDICATES TO BE GAS HEATER? | | | | 2)NOTE: PLEASE SEE THAT PERMIT APPLICAT- | | ION DID NOT COME BACK IN WITH RESUB.? | | PLEASE NOTE, AS PER COMMENT FROM FIRST | | REVIEW. APPL INDUCATED A SPA AND PLANS | | DO NOT? PLEASE SEE THAT SPECS FOR POOL | | HEATER WERE NOT RESUBBED.GAS/ELEC? | | | | PLEASE SEE ANY PLUMB REVIEW COMMENTS | | THAT MAY HAVE AN AFFECT ON POOL PLAN. | | | | PLEASE SUBMIT THE ORIG PACKAGE AND | | SUBMIT THE ABOVE INFORMATION FOR REVIEW. | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | EELCTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-15 |
Time |
13:46 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-09-08 |
Time |
17:34 |
Sent To |
B |
|
Notes |
2003-09-08 00:00:00 | ***************** UNSAT *************** | | | | 1)NOTE: PLEASE CLARIFY IF HEATER IS GAS | | OR ELECTRIC? ELECTRICAL RISER SHOWS | | BRANCH CIRCUIT FOR HEAT PUMP? #6`S? | | | | 2)NOTE: PLEASE SEE PERMIT APPLICATION, | | SHOWS SPA ALONG WITH POOL? PLEASE SEE | | PLAN, PLEASE CLARIFY WHERE SPA IS? | | | | 3)NOTE: PLEASE SEE ATTACHED COPY OF | | FAC 61G15-23.002. PLEASE INCLUDE THE | | CERTIFICATE OF AUTHORIZATION # ONTITLE | | BLOCK AS REQ'D UNDER FS 471. | | | | PLEASE SEE PLUMB COMMENTS AS ELECTRICAL | | AND PLUMB ARE ON SAME SHEET. | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-09 |
Time |
09:52 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-09 |
Time |
09:52 |
Sent To |
E |
|
Notes |
2003-10-09 00:00:00 | TO DP DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-09-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-15 |
Time |
13:46 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-15 |
Time |
13:46 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-03 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-03 |
Time |
14:26 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2003-12-16 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-16 |
Time |
13:19 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-12-16 |
Time |
13:19 |
Sent To |
E |
|
Notes |
2003-12-16 00:00:00 | RESTAMP OK - | | | | | | | | | | | | FBC-2001 424.2.7.2 PUMPS AND EQUIP- | | MENT SHALL BE MOUNTED ON A SUBSTANTIAL | | BASE IN A MANNER THAT WILL ELIMINATE | | STRAIN ON PIPING. SLAB SHALL BE A NOMIN- | | AL 4" THICK. (DETAIL) | | | | | | | | | | FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | | | | | | | | | | | Z |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-10-10 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-10-10 |
Time |
18:05 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-10-10 |
Time |
18:05 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-10-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-10 |
Time |
14:31 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-10-02 |
Time |
18:16 |
Sent To |
B |
|
Notes |
2003-10-02 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | FLORIDA ADMIN. CODE | | | | 1) COMMENTS FROM FIRST REVIEW HAVE NOT | | BEEN ADDRESSED. SEE ATTACHED SHEET FROM | | FIRST REVIEW. | | 2) CERTIFICATE OF AUTHORIZATION REQUIRED | | PER 61G15-23.002(2) | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-09-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-19 |
Time |
06:20 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-09-06 |
Time |
17:18 |
Sent To |
E |
|
Notes |
2003-09-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 424.2 SWIMMING POOLS | | | | A) PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING IN- | | FORMATION REQUIRED FOR PLAN REVIEW | | 1) FBC-2001424.2.6.6.5 WHERE PROVIDED, | | THE VACUUM OR PRESSURE CLEANER FITTING | | SHALL BE LOCATED AT LEAST 6" AND NOT | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | THE SKIMMER. (DETAIL OR ADD TO NOTES) | | 2) FBC-2001 424.2.7.2 PUMPS AND EQUIP- | | MENT SHALL BE MOUNTED ON A SUBSTANTIAL | | BASE IN A MANNER THAT WILL ELIMINATE | | STRAIN ON PIPING. SLAB SHALL BE A NOMIN- | | AL 4" THICK. (DETAIL) | | 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL | | ORD. #2853-95, BACKFLOW REQUIRED ON | | WATER SERVICE. (ADD TO NOTES) | | 4) FBC-2001 424.2.12.1 PRESSURE TESTS. | | PER MANUFACTURE RECOMMENDATIONS, NO AIR | | TEST SHALL BE APPROVED FOR PVC PIPE AND | | FITTINGS. (ADD TO NOTES) | | 5) FBC-2001 424.2.13.2JOINTS AND CON- | | NECTIONS, FBC PLMG SEC 605.21, PURPLE | | PRIMER REQUIRED ON PVC PIPING. (ADD TO | | NOTES) | | 6) FBC-2001 424.2.14.4 CONNECTIONS, ALL | | WATER HEATING EQUIPMENT SHALL BE INSTAL- | | LED WITH FLANGES OR UNION CONNECTIONS | | ADJACENT TO THE HEATER. (ADD TO NOTES) | | 7) FBC02001 424.2.15 GAS PIPING SHALL | | COMPLY WITH FBC FUEL GAS. SEPARATE PLANS | | AND PERMIT REQUIRED. (ADD TO NOTES) | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-09-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-03 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
P |
|
Notes |
2003-09-04 00:00:00 | 9/3/03 APPROVED BY DANA LITTLES MM |
|
|