Plan Review Details - Permit 03081472
Plan Review Stops For Permit 03081472
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-09-09 Cont ID  
Sent By btrobaug Date 2003-12-16 Time 14:28 Rev Time 0.50
Received By lsmith Date 2003-09-09 Time 11:34 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2003-12-16 Cont ID  
Sent By btrobaug Date 2003-12-16 Time 14:28 Rev Time 0.25
Received By btrobaug Date 2003-12-16 Time 14:28 Sent To B
Notes
2003-12-16 00:00:00RESTAMP./WRT.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2003-10-10 Cont ID  
Sent By kstevens Date 2003-12-16 Time 13:38 Rev Time 0.25
Received By dpalmer Date 2003-10-10 Time 14:31 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2003-09-19 Cont ID  
Sent By csiegber Date 2003-10-09 Time 09:52 Rev Time 0.25
Received By dpalmer Date 2003-09-19 Time 06:20 Sent To P
Notes
2003-09-19 00:00:00************ UNSAT ***************
  
 1)NOTE: PLEASE SEE THAT AN ELECTRICAL
 HEAT PUMP IS STILL SHOWN ON RISER AND
 PLAN INDICATES TO BE GAS HEATER?
  
 2)NOTE: PLEASE SEE THAT PERMIT APPLICAT-
 ION DID NOT COME BACK IN WITH RESUB.?
 PLEASE NOTE, AS PER COMMENT FROM FIRST
 REVIEW. APPL INDUCATED A SPA AND PLANS
 DO NOT? PLEASE SEE THAT SPECS FOR POOL
 HEATER WERE NOT RESUBBED.GAS/ELEC?
  
 PLEASE SEE ANY PLUMB REVIEW COMMENTS
 THAT MAY HAVE AN AFFECT ON POOL PLAN.
  
 PLEASE SUBMIT THE ORIG PACKAGE AND
 SUBMIT THE ABOVE INFORMATION FOR REVIEW.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 EELCTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-09-08 Cont ID  
Sent By csiegber Date 2003-09-15 Time 13:46 Rev Time 0.50
Received By dpalmer Date 2003-09-08 Time 17:34 Sent To B
Notes
2003-09-08 00:00:00***************** UNSAT ***************
  
 1)NOTE: PLEASE CLARIFY IF HEATER IS GAS
 OR ELECTRIC? ELECTRICAL RISER SHOWS
 BRANCH CIRCUIT FOR HEAT PUMP? #6`S?
  
 2)NOTE: PLEASE SEE PERMIT APPLICATION,
 SHOWS SPA ALONG WITH POOL? PLEASE SEE
 PLAN, PLEASE CLARIFY WHERE SPA IS?
  
 3)NOTE: PLEASE SEE ATTACHED COPY OF
 FAC 61G15-23.002. PLEASE INCLUDE THE
 CERTIFICATE OF AUTHORIZATION # ONTITLE
 BLOCK AS REQ'D UNDER FS 471.
  
 PLEASE SEE PLUMB COMMENTS AS ELECTRICAL
 AND PLUMB ARE ON SAME SHEET.
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-09 Cont ID  
Sent By csiegber Date 2003-10-09 Time 09:52 Rev Time 0.00
Received By csiegber Date 2003-10-09 Time 09:52 Sent To E
Notes
2003-10-09 00:00:00TO DP DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-15 Cont ID  
Sent By csiegber Date 2003-09-15 Time 13:46 Rev Time 0.00
Received By csiegber Date 2003-09-15 Time 13:46 Sent To E
Notes
2003-09-15 00:00:00RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-09-03 Time 14:26 Rev Time 0.00
Received By csiegber Date 2003-09-03 Time 14:26 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2003-12-16 Cont ID  
Sent By kstevens Date 2003-12-16 Time 13:19 Rev Time 0.50
Received By kstevens Date 2003-12-16 Time 13:19 Sent To E
Notes
2003-12-16 00:00:00RESTAMP OK -
  
  
  
  
  
 FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
  
  
  
  
 FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
  
  
  
  
  
 Z

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-10-10 Cont ID  
Sent By kstevens Date 2003-10-10 Time 18:05 Rev Time 0.50
Received By kstevens Date 2003-10-10 Time 18:05 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-10-02 Cont ID  
Sent By dpalmer Date 2003-10-10 Time 14:31 Rev Time 0.50
Received By kstevens Date 2003-10-02 Time 18:16 Sent To B
Notes
2003-10-02 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
 FLORIDA ADMIN. CODE
  
 1) COMMENTS FROM FIRST REVIEW HAVE NOT
 BEEN ADDRESSED. SEE ATTACHED SHEET FROM
 FIRST REVIEW.
 2) CERTIFICATE OF AUTHORIZATION REQUIRED
 PER 61G15-23.002(2)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-08 Cont ID  
Sent By dpalmer Date 2003-09-19 Time 06:20 Rev Time 0.50
Received By kstevens Date 2003-09-06 Time 17:18 Sent To E
Notes
2003-09-06 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER. (DETAIL OR ADD TO NOTES)
 2) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 4) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 6) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 7) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED. (ADD TO NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-03 Time 14:26 Rev Time 0.00
Received By mmclean Date   Time   Sent To P
Notes
2003-09-04 00:00:009/3/03 APPROVED BY DANA LITTLES MM