Plan Review Stops For Permit 03081417 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-09-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-03 |
Time |
11:10 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2003-09-05 |
Time |
13:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-06-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-24 |
Time |
12:46 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-06-24 |
Time |
12:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2004-06-17 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-22 |
Time |
10:35 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-06-17 |
Time |
09:28 |
Sent To |
|
|
Notes |
2004-06-17 00:00:00 | *** UNSAT *** | | | | 1)NOTE: PLEASE SEE SD IS REQUIRED TO BE | | MOVED INTO MATER BEDROOM. PLAN SHOWS A | | HEADERIN DOORWAY. | | NFPA-72 | | | | 2)NOTE: PLEASE SEE SEAL IS NOT VISABLE, | | PLEASE SEE SEAL MUST BE IMBOSSED, RAISED | | SEAL, CLEAR AND VISBLE. FS 471.025 | | | | 3)NOTE: PLEASE SHOW LOCATION OF POOL | | PANEL "C" ON PLANS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-08-28 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-16 |
Time |
15:07 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-28 |
Time |
16:16 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-06-22 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-22 |
Time |
10:35 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-22 |
Time |
10:35 |
Sent To |
E |
|
Notes |
2004-06-22 00:00:00 | SENT TO DP DESK/REVISION |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-06-16 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2004-06-16 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2004-06-16 |
Time |
15:07 |
Sent To |
E |
|
Notes |
2004-06-16 00:00:00 | SENT TO DP DESK/DRAWINGS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
09:39 |
Sent To |
P |
|
Notes |
2003-10-24 00:00:00 | TO KS BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
16:38 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-25 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
11:13 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-28 |
Time |
16:16 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-29 |
Time |
07:11 |
Sent To |
P |
|
Notes |
2003-08-29 00:00:00 | PROVISO: | | | | 1. BALANCE AIR RETURN - RETURN TRANSFER | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM IT'S SERVING & THE | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. | | | | 2. ATTIC ACCESS OPENING SHALL BE NO LESS | | THAN 30" X 22" AS PER 2001 FBC(M) 306.3 | | | | 2001 FBC CHAPTER 13 610.1.ABC.3.5.2 - | | 1. THE SERVICE PANEL OF THE EQUIPMENT IS | | LOCATED WITHIN 6 FT OF AN ATTIC | | ACCESS. | | 2. A DEVICE IS INSTALLED TO ALERT THE | | OWNER OR SHUT DOWN WHEN THE | | CONDENSATE DRAIN IS NOT WORKING | | PROPERLY. | | 4. A NOTICE IS POSTED ON THE ELECTRIC | | SERVICE PANEL INDICATING TO THE | | HOMEOWNER THAT THE AIR HANDLER IS | | LOCATED IN THE ATTIC. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-10-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-10-31 |
Time |
18:17 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-10-31 |
Time |
18:17 |
Sent To |
|
|
Notes |
2003-10-31 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SANITARY RISER DIAGRAM REVISION DOES | | NOT REFLECT THE FLOOR PLAN. PLEAS SUBMIT | | A SANT. RISER DIAGRAM THAT REFLECT THE | | FLOOR PLAN AND ACTUAL INSTALLATION. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
09:39 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-09-03 |
Time |
11:10 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
11:13 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|