Plan Review Stops For Permit 03081411 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-09-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-03 |
Time |
11:01 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2003-09-05 |
Time |
11:08 |
Sent To |
|
|
Notes |
2003-09-05 00:00:00 | A NOTICE OF COMMENCEMENT MUST BE | | SUBMITTED BEFORE A PERMIT CAN BE | | PRINTED. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713DIRECT LINE |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-08-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-08-09 |
Time |
17:23 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-08-09 |
Time |
17:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-06-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-06-07 |
Time |
09:52 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-06-07 |
Time |
09:49 |
Sent To |
|
|
Notes |
2004-06-07 00:00:00 | REDLINED, PANEL 'C' STILL NOT SHOWN ON | | PLANS? | | REVISE BEFORE FINAL. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-08-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-02 |
Time |
14:41 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-28 |
Time |
16:34 |
Sent To |
M |
|
Notes |
2003-08-28 00:00:00 | *** NOTE ** | | | | REDLINED GFI RECEPT FOR A/C UNITS 210.63 | | PANEL 'C' NOT SHOWN ON PLANS? |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-06-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-06-02 |
Time |
14:41 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-06-02 |
Time |
14:41 |
Sent To |
E |
|
Notes |
2004-06-02 00:00:00 | TO | | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-01-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-13 |
Time |
14:40 |
Sent To |
M |
|
Notes |
2004-01-13 00:00:00 | TO PK BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
09:39 |
Sent To |
P |
|
Notes |
2003-10-24 00:00:00 | TO KS BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
16:35 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-25 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
11:09 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-01-26 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-01-26 |
Time |
14:41 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2004-01-26 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-13 |
Time |
14:40 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-09-02 |
Time |
09:56 |
Sent To |
P |
|
Notes |
2003-09-02 00:00:00 | PROVISO: | | PLEASE NOTE THE FOLLOWING REQUIREMENTS | | FOR RETURN AIR EFFECTIVE JUNE 30, 2003: | | | | BALANCE AIR RETURN - RETURN TRANSFER | | SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL | | AREA (SQ INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM IT'S SERVING & THE | | DOOR HAVING AN UNRESTRICTED 1" UNDERCUT. | | | | ALL SUPPLY AIR INTO THE MASTER SUITE | | SHALL BE INCLUDED. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-10-31 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-10-31 |
Time |
18:06 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-10-31 |
Time |
18:06 |
Sent To |
|
|
Notes |
2003-10-31 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SANITARY RISER DIAGRAM DOES NOT RE- | | FLECT THE FLOOR PLAN. LAUNDRY SINK IS | | NOT SHOWN ON RISER DIAGRAM, AND THE 2ND | | FLOOR BATHROOM SHOWS A SHOWER ON THE | | RISER BUT A TUB IS SHOWN ON THE FLOOR | | PLAN. PLEASE CORRECT THE RISER DIAGRAM | | AND RESUBMIT. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
09:39 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-09-03 |
Time |
10:59 |
Sent To |
B |
|
Notes |
2003-09-03 00:00:00 | PASSED/PROVISO | | | | REVISION REQUIRED - SHOWER NOT VENTED IN | | CABANA BATH. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
11:10 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|