Plan Review Details - Permit 03081411
Plan Review Stops For Permit 03081411
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-09-05 Cont ID  
Sent By kstevens Date 2003-09-03 Time 11:01 Rev Time 2.00
Received By lsmith Date 2003-09-05 Time 11:08 Sent To  
Notes
2003-09-05 00:00:00A NOTICE OF COMMENCEMENT MUST BE
 SUBMITTED BEFORE A PERMIT CAN BE
 PRINTED.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713DIRECT LINE

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-08-09 Cont ID  
Sent By btrobaug Date 2004-08-09 Time 17:23 Rev Time 0.50
Received By btrobaug Date 2004-08-09 Time 17:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-06-07 Cont ID  
Sent By dpalmer Date 2004-06-07 Time 09:52 Rev Time 0.33
Received By dpalmer Date 2004-06-07 Time 09:49 Sent To  
Notes
2004-06-07 00:00:00REDLINED, PANEL 'C' STILL NOT SHOWN ON
 PLANS?
 REVISE BEFORE FINAL.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By csiegber Date 2004-06-02 Time 14:41 Rev Time 0.50
Received By dpalmer Date 2003-08-28 Time 16:34 Sent To M
Notes
2003-08-28 00:00:00*** NOTE **
  
 REDLINED GFI RECEPT FOR A/C UNITS 210.63
 PANEL 'C' NOT SHOWN ON PLANS?

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-02 Cont ID  
Sent By csiegber Date 2004-06-02 Time 14:41 Rev Time 0.00
Received By csiegber Date 2004-06-02 Time 14:41 Sent To E
Notes
2004-06-02 00:00:00TO
 TO DP DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-01-13 Cont ID  
Sent By csiegber Date 2004-01-13 Time 14:40 Rev Time 0.00
Received By csiegber Date 2004-01-13 Time 14:40 Sent To M
Notes
2004-01-13 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-10-24 Cont ID  
Sent By csiegber Date 2003-10-24 Time 09:39 Rev Time 0.00
Received By csiegber Date 2003-10-24 Time 09:39 Sent To P
Notes
2003-10-24 00:00:00TO KS BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 16:35 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 16:35 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-25 Cont ID  
Sent By mmclean Date 2003-08-25 Time 13:30 Rev Time 0.00
Received By csiegber Date 2003-08-25 Time 11:09 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-01-26 Cont ID  
Sent By pkrauss Date 2004-01-26 Time 14:41 Rev Time 0.25
Received By pkrauss Date 2004-01-26 Time 14:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-02 Cont ID  
Sent By csiegber Date 2004-01-13 Time 14:40 Rev Time 0.25
Received By pkrauss Date 2003-09-02 Time 09:56 Sent To P
Notes
2003-09-02 00:00:00PROVISO:
 PLEASE NOTE THE FOLLOWING REQUIREMENTS
 FOR RETURN AIR EFFECTIVE JUNE 30, 2003:
  
 BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-10-31 Cont ID  
Sent By kstevens Date 2003-10-31 Time 18:06 Rev Time 0.50
Received By kstevens Date 2003-10-31 Time 18:06 Sent To  
Notes
2003-10-31 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
 FBC-2001 CHAPTER 1
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. LAUNDRY SINK IS
 NOT SHOWN ON RISER DIAGRAM, AND THE 2ND
 FLOOR BATHROOM SHOWS A SHOWER ON THE
 RISER BUT A TUB IS SHOWN ON THE FLOOR
 PLAN. PLEASE CORRECT THE RISER DIAGRAM
 AND RESUBMIT.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-10-24 Time 09:39 Rev Time 0.33
Received By kstevens Date 2003-09-03 Time 10:59 Sent To B
Notes
2003-09-03 00:00:00PASSED/PROVISO
  
 REVISION REQUIRED - SHOWER NOT VENTED IN
 CABANA BATH.

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-08-25 Time 11:10 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***