Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-09-03 Cont ID  
Sent By csiegber Date 2003-08-25 Time 09:41 Rev Time 0.30
Received By pkrauss Date 2003-09-03 Time 07:24 Sent To  
Notes
2003-09-03 00:00:00PROVISO:
  
 1. BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
 PLEASE NOTE ALL SUPPLY AIR INTO THE
 MASTER SUITE SHALL BE INCLUDED (EXCEPT
 FOR THE BATHROOM). 2001 FBC(M) 601.4.
  
 2. BATHROOMS SHALL HAVE A WINDOW WITH
 A MINIMUM OF 3 SQ FT OF OPEN SPACE OR
 BE MECHANICALLY VENTILATED. 2001 FBC(M)
 402.3.1.
  