Plan Review Stops For Permit 03081358 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-08-27 |
Time |
11:12 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2003-08-27 |
Time |
11:10 |
Sent To |
|
|
Notes |
2003-08-27 00:00:00 | MASTER PLAN 02081374 MODEL "E" | | 1609.4.3 LOAD REDUCTION. | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | 1609.4.1 OR 1609.4.2, THE COMBINED | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | FROM THE LOAD COMBINATION OF THE DEAD | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | CODE OR A REFRENCED STANDARD SHALL NOT | | BE USED WITH THESE LOAD COMBINATIONS | | EXCEPT THAT A DURATION OF LOAD INCREASE | | SHALL BE PERMITTED IN ACCORDANCE WITH | | CHAPTER 23. | | | | RE-EVALUATE TRUSS ANCHOR SCHEDULE BEFORE | | FOOR FRAMING INSPECTION. | | JIM WITMER | | (561)805-6715 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-08-27 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-08-27 |
Time |
11:10 |
Sent To |
|
|
Notes |
2003-08-27 00:00:00 | MASTER PLAN 02081374 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-11-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-14 |
Time |
09:47 |
Sent To |
M |
|
Notes |
2003-11-14 00:00:00 | TO PK BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-09-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-19 |
Time |
11:53 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-19 |
Time |
11:53 |
Sent To |
P |
|
Notes |
2003-09-19 00:00:00 | TO KS BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-09-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-19 |
Time |
11:51 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-19 |
Time |
11:51 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-09-05 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-05 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-05 |
Time |
16:44 |
Sent To |
P |
|
Notes |
2003-09-05 00:00:00 | TO JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
08:16 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-11-24 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2003-11-24 |
Time |
17:32 |
Rev Time |
0.25 |
Received By |
rregueir |
Date |
2003-11-24 |
Time |
17:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-08-27 |
Time |
11:10 |
Sent To |
|
|
Notes |
2003-08-27 00:00:00 | MASTER PLAN 02081374 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-10-06 |
Time |
09:08 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-10-06 |
Time |
09:07 |
Sent To |
|
|
Notes |
2003-10-06 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | NO CHANGES SHOWN ON REVISION FROM STAMP- | | ED SET ON FILE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-06-16 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-19 |
Time |
11:53 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-09-16 |
Time |
13:17 |
Sent To |
|
|
Notes |
2003-09-17 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | REVISION SUBMITTED IS THE SAME AS SHEET | | ON FILE. NO CHANGES TO FILE COPY. | | SHOW CHANGES ON REVISION - SHOW NEW | | LOCATION OF WATER HEATER. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-05 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-08-27 |
Time |
11:10 |
Sent To |
|
|
Notes |
2003-08-27 00:00:00 | MASTER PLAN 02081374 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-08-27 |
Time |
11:10 |
Sent To |
|
|
Notes |
2003-08-27 00:00:00 | 8-25-03 OK PER M. MCLEAN |
|
|