Plan Review Stops For Permit 03081254 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
Sent By |
hpiskura |
Date |
2003-09-02 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
hpiskura |
Date |
2003-09-02 |
Time |
08:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-12-18 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-12-18 |
Time |
15:37 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-12-18 |
Time |
15:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-08-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:38 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-29 |
Time |
07:06 |
Sent To |
|
|
Notes |
2003-08-29 00:00:00 | ********** NOTES REDLINED ********** | | | | MISSING SIGN CIRCUIT, 600.5 | | MISSING SHOW WINDOW RECEPTS, 210.62 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2003-10-21 |
|
|
Cont ID |
|
Sent By |
nmccray |
Date |
2003-10-21 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
nmccray |
Date |
2003-10-21 |
Time |
11:07 |
Sent To |
|
|
Notes |
2003-10-21 00:00:00 | ************PROVISO********************* | | SEPARATE PLANS AND PERMITS ARE REQUIRED | | FOR THE FIRE ALARM AND FIRE SPRINKLER | | SYSTEMS REMODEL. | | | | NATE MCCRAY, CAPTAIN | | 805-6722OR 835-2910 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2003-09-04 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2003-09-04 |
Time |
07:49 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2003-09-04 |
Time |
07:48 |
Sent To |
|
|
Notes |
2003-09-04 00:00:00 | 1) FIRE ALARM NOTES # 17 INDICATES | | A SUPERVISORY SIGNAL WHEN DUCT | | SMOKE DETECTORS ARE ACTIVATED. ALARM | | SIGNALS ALLOWED ONLY. | | | | 2) FIRE ALARM NOTES # 19 INCORRECT. | | FIRE ALARM CIRCUITS SHALL BE CLASS A, | | STYLE D. | | | | 3) SEPARATE PLANS AND PERMITS REQUIRED | | FOR FIRE ALARM REMODEL. | | | | 4) PROVIDE SEPARATE PLANS AND PERMITS | | FOR FIRE SPRINKLER REMODEL. | | | | MIKE CARSILLO, ASSISTANT FIRE MARSHAL | | 835-2910 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-12-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-17 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-17 |
Time |
16:38 |
Sent To |
E |
|
Notes |
2003-12-17 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-12-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-03 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-12-03 |
Time |
09:51 |
Sent To |
P |
|
Notes |
2003-12-03 00:00:00 | TO KS BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-10-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-09 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-09 |
Time |
16:15 |
Sent To |
|
|
Notes |
2003-10-09 00:00:00 | TO COMM BD#63 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-21 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-21 |
Time |
15:46 |
Sent To |
|
|
Notes |
2003-08-21 00:00:00 | COMM BD #46 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-09-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-23 |
Time |
12:25 |
Rev Time |
0.45 |
Received By |
pkrauss |
Date |
2003-09-23 |
Time |
11:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2004-01-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2004-01-09 |
Time |
13:05 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2004-01-09 |
Time |
13:05 |
Sent To |
|
|
Notes |
2004-01-09 00:00:00 | REVISION OK - ADD TWO W/C'S FOR DISPLAY | | ONLY - WORKING MODELS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2003-12-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-12-17 |
Time |
17:28 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-12-17 |
Time |
17:28 |
Sent To |
|
|
Notes |
2003-12-17 00:00:00 | DENIED | | REFERENCE: FLA. ADMIN. CODE | | FLA. STATUTES | | | | ENGINEERS SIGNATURE REQUIRED ON SEAL PER | | FAC 61G15-23.002(1) & FS 471.025. - PER | | RULING BY FBPE AND BLDG. OFFICIAL THE | | SIGNATURE SHALL CONTAIN MINIMUM OF FIRST | | AND LAST NAME. INITIALS ARE NOT ACCEPT- | | ABLE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-12-03 |
Time |
09:51 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-10-27 |
Time |
11:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2003-10-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-10-25 |
Time |
14:58 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-10-25 |
Time |
14:30 |
Sent To |
|
|
Notes |
2003-10-25 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | | | 1) SECTION 402.1 SUBMIT MANUFACTURE IN- | | FORMATION, (SPECIFICATION SHEETS) SHOW- | | ING THAT THE DRINKING FOUNTAIN AND THE | | LAUNDRY TUB CONFORM TO STANDARDS CITED | | IN THIS CODE.SECOND NOTICE. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-09-23 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-09-23 |
Time |
07:54 |
Rev Time |
1.25 |
Received By |
kstevens |
Date |
2003-09-23 |
Time |
07:54 |
Sent To |
|
|
Notes |
2003-09-23 00:00:00 | DENIED | | REFERENCE: FBC-2001 PLUMBING | | FBC-2001 CHAPTER 1 | | | | 1) SHT P0.1 DOMESTIC WATER ISOMETRIC, | | WATER HAMMER ARRESTORS SHALL BE LOCATED | | NEAR THE FIXTURE IN AN "EFFECTIVE RANGE" | | NOT IN THE CEILING AS SHOWN. PDI-WH 201 | | AND MANUF. INSTALL. INSTRUCT. (SEE NOTE | | #13 OF THE PLUMING NOTES). | | 2) SUBMIT PRODUCT APPROVAL SHEETS FOR | | TOTO FIXTURES, DRINKING FOUNTAIN, AND | | LAUNDRY TUB. | | 3) 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | WHO HAVE DIFFICULTY BENDING OR STOOPING | | AT DRINKING FOUNTAIN. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 653-2692 | | E-MAIL [email protected] |
|
|