Plan Review Details - Permit 03080864
Plan Review Stops For Permit 03080864
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-25 Cont ID  
Sent By csiegber Date 2003-09-26 Time 16:08 Rev Time 2.00
Received By rmcdouga Date 2003-09-25 Time 07:14 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-02 Cont ID  
Sent By csiegber Date 2003-09-15 Time 09:54 Rev Time 3.50
Received By rmcdouga Date 2003-09-02 Time 14:21 Sent To  
Notes
2003-09-02 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) THE SURVEY IS THE REVERSE OF THE
 ARCHITECTURAL PLANS. PLEASE CORRECT.
  
 4) THE DOOR TO THE TOILET IN THE MASTER
 BATH DOES NOT COMPLY WITH THE 29" CLEAR
 OPENING REQUIRED BY FBC 11-4.22.2.
  
 5) THE DIMENSIONS FOR THE STAIR RISERS
 AND TREADS ON A-2 DOES NOT CORRESPOND
 WITH DETAILS 12 AND 13 ON A-8. THE
 INTERMEDIATE RAILS ON THE STAIRS ARE
 REQUIRED TO REJECT A 4" SPHERE PER FBC
 1015.3.
  
 6) REVISE DETAIL 4 ON A-8. STUCCO ON
 VERTICAL METAL BASE IS REQUIRED TO BE
 7/8" THICK PER FBC 2504.2.1 AND ASTM C
 926.
  
 7) THE TWO STORY WALL SECTION ON A-6
 SPECIFIES AN 18" WIDE FOOTING AND THE
 FOOTING SCHEDULE ON A-1 REQUIRES A 20"
 WIDE FOOTING. PLEASE CORRECT.
  
 8) THE COLUMN IS NOT SPECIFIED AT THE
 F10 PAD ON SHEET A1.
  
 9) REVISE THE BUCK DETAIL ON A-8. THE
 FRAMES ARE REQUIRED TO BE FASTENED
 THROUGH THE 1X BUCKS INTO THE SUBSTRATE
 PER FBC 1707.4.4.2.
  
 10) SUBMIT AN INSTALLATION SCHEDULE AND
 KEY PLAN FOR THE STORM PANELS.
  
 11) REVISE THE STUCCO NOTES ON SECTION
 A-A ON A-6. HIGH RIB METAL LATH IS
 REQUIRED TO BE FASTENED AT EVERY RIB
 (4"O.C.) PER ASTM C 1063. SEE FBC
 2504.2.2.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By btrobaug Date 2003-08-21 Time 11:48 Rev Time 0.10
Received By pkrauss Date 2003-08-28 Time 07:33 Sent To M
Notes
2003-08-28 00:00:00APPROVED & STAMPED BY W.R. TROBAUGH
 8-26-03

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-26 Cont ID  
Sent By csiegber Date 2003-09-26 Time 16:08 Rev Time 0.00
Received By csiegber Date 2003-09-26 Time 16:08 Sent To B
Notes
2003-09-26 00:00:00TO RM DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-15 Cont ID  
Sent By csiegber Date 2003-09-15 Time 09:54 Rev Time 0.00
Received By csiegber Date 2003-09-15 Time 09:54 Sent To B
Notes
2003-09-15 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-21 Cont ID  
Sent By btrobaug Date 2003-08-21 Time 11:48 Rev Time 0.00
Received By btrobaug Date 2003-08-21 Time 11:48 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-15 Cont ID  
Sent By mmclean Date 2003-08-21 Time 10:31 Rev Time 0.00
Received By dbaxter Date 2003-08-15 Time 13:32 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By pkrauss Date 2003-08-28 Time 07:33 Rev Time 0.25
Received By pkrauss Date 2003-08-28 Time 07:29 Sent To P
Notes
2003-08-28 00:00:00PROVISO:
  
 BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-09-18 Cont ID  
Sent By rmcdouga Date 2003-09-18 Time 09:58 Rev Time 0.15
Received By rmcdouga Date 2003-09-18 Time 09:57 Sent To  
Notes
2003-09-18 00:00:00IF OPTIONAL LAUNDRY TUB IS INSTALLED A
 REVISION WILL BE REQUIRED. SEPARATE
 STACKS.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-28 Cont ID  
Sent By pkrauss Date 2003-08-28 Time 07:29 Rev Time 0.50
Received By kstevens Date 2003-08-28 Time 09:54 Sent To B
Notes
2003-08-28 00:00:00PASSED/PROVISO
  
 IF OPTIONAL LAUNDRY TUB INSTALLED, A
 REVISION IS REQUIRED. SEPARATE STACKS
 REQUIRED FOR L/T & W/M

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-21 Cont ID  
Sent By dbaxter Date 2003-08-15 Time 13:32 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***