Plan Review Details - Permit 03080643
Plan Review Stops For Permit 03080643
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-18 Cont ID  
Sent By jgomez Date 2003-09-18 Time 15:08 Rev Time 2.00
Received By jgomez Date 2003-09-18 Time 15:08 Sent To PC
Notes
2003-09-18 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOORS WITH SIDELITE ASSEMBLY AS SHOWN
 ON PLANS.
 3-WINDOW MULLION PRODUCT APPROVAL AND
 LETTER EXTENDING EXPIRATION DATEARE
 EXPIRED. RESUBMIT AS REQUIRED.
 4-PROVIDE PRODUCT APPROVAL FOR FIXED
 WINDOW ABOVE FAMILY ROOM. SEE PLANS
 FOR SIZE.
 5-PROVIDE COMPLETE SOIL TEST REPORT WITH
 SOIL BEARING CAPACITY. SOIL PREP. AND
 FOOTING RECOMMENDATIONS. SECTION
 1804.1.7 CITY AMENDMENTS TO FBC 2001.
 6-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEE PLANS. SEC. 2405.2 FBC 2001.
 7-MISSING SOME CONNECTORS. SEE ROOF PLAN
 AND SPECIFY THEM AS REQUIRED. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 8-PROVIDE DETAIL AT CONNECTION OF GABLE
 END TRUSS TO GABLE END CONCRETE BLOCK
 WALL AT REAR PORCH. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 9-CLARIFY DETAIL 5/A6. SEE ROOF PLAN.
 SEC. 104.2.1.2 CITY AMENDMENTS TO FBC.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-05 Cont ID  
Sent By csiegber Date 2003-09-15 Time 14:17 Rev Time 3.00
Received By jgomez Date 2003-09-05 Time 15:48 Sent To PC
Notes
2003-09-05 00:00:00CHECKLIST:
 1-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOOR WITH SIDELITE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 B)OVERHEAD GARAGE DOORS.
 C)EXTERIOR SWING DOOR AT GARAGE.
 D)SINGLE HUNG WINDOWS.
 E)WINDOW MULLIONS.
 F)SLIDING GLASS DOORS.
 G)FIXED WINDOWS. SEE PLANS FOR SIZES.
 H)ARCHED WINDOWS. SEE PLANS.
 I)ROOF TILE.
  
 2-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS OR APPLY FOR SEPARATE PERMIT.
 3-NEED TWO COPIES OF ENERGY CALCULATIONS
 WITH ENGINEER'S ORIGINAL SIGNATURE,
 SEAL, DATE, ETC, AS REQUIRED BY
 CHAPTER 471 FLORIDA STATUTES.
 4-NEED COMPLETE SOIL TEST REPORT THAT
 INCLUDES FOOTING RECOMMENDATIONS AND
 SOIL BEARING CAPACITY. SECTION
 1804.2.2 CITY AMENDMENTS TO FBC 2001.
 5-NEED RECORDED NOTICE OF COMMENCEMENT.
 6-SHEET A-1: A)REVISE DETAIL #38.
 FOOTING TO BE 12" MINIMUM BELOW GRADE.
 SEC. 1804.1.3 FBC 2001.
 **INDICATE 4" MINIMUM FINISH FLOOR
 ELEVATION ABOVE GRADE. SECTION
 1804.1.7 CITY AMENDMENTS TO FBC 2001.
 7-THERE ARE TWO #A1 DRAWINGS AND DRAWING
 A3 IS NOT NUMBERED. REVISE AS REQUIRED
 8-CLARIFY BEAMS SPECIFIED FOR COVERED
 PORCH. SEE DETAILS ON SHEET A-6 AND
 CLARIFY AS REQUIRED.
 9-SHEET A-4:REVISE BUCK DETAILS TO
 COMPLY WITH SECTION 1717.4.4.2 FBC/01
 10-SPECIFY ANCHOR EMBEDMENT AND WASHER
 SIZE REQUIRED FOR GARAGE DOOR
 STRUCTURAL BUCK DETAILS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.
 11-SHEET A-5: A)ALL GABLE END DETAILS TO
 MATCH ACTUAL CONDITIONS SHOWN ON THE
 REAR ELEVATION AND PLANS. REVISE AS
 REQUIRED.
 B)CLARIFY HOW ARE GABLE END DETAILS
 DESIGN TO PROVIDE CONTINUOUS LATERAL
 SUPPORT AS REQUIRED BY SEC. 2117 AND
 2313.4 FBC 2001.
 C)THERE ARE SOME AREAS THAT HAVE NO
 CONNECTORS SPECIFIED. SPECIFY THEM
 AS REQUIRED.
 D)DETAIL 5/A6 DOESN'T APPLY TO ACTUAL
 CONDITIONS SHOWN ON PLAN. REVISE/
 CLARIFY AS REQUIRED. SEC. 104.2.1.2
 CITY AMENDMENTS TO FBC 2001.
 12-PROVIDE GENERAL SPECIFICATIONS FOR
 FIREBLOCKING AT ALL CONCEALED SPACES.
 SEE SEC. 2305 FBC 2001.
 13-PROVIDE NAILING DIAPHRAGM SHOWING THE
 NAILING ZONES. SEE SECTION 2306 CITY
 AMENDMENTS TO FBC 2001.
 14-CLARIFY OWNERSHIP OF THIS PROPERTY.
 OWNER INFORMATION ON APPLICATION DOES
 NOT MATCH INFORMATION ON COMPUTER.
 REVISE AS REQUIRED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-20 Cont ID  
Sent By jleahy Date 2004-04-20 Time 08:39 Rev Time 0.15
Received By jleahy Date 2004-04-20 Time 08:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-14 Cont ID  
Sent By jleahy Date 2004-04-14 Time 14:46 Rev Time 0.15
Received By jleahy Date 2004-04-14 Time 14:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-21 Cont ID  
Sent By csiegber Date 2004-04-13 Time 11:50 Rev Time 0.50
Received By btrobaug Date 2003-08-21 Time 17:40 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-13 Cont ID  
Sent By csiegber Date 2004-04-13 Time 11:50 Rev Time 0.00
Received By csiegber Date 2004-04-13 Time 11:50 Sent To E
Notes
2004-04-13 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 11:33 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 11:32 Sent To M
Notes
2004-02-13 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-15 Cont ID  
Sent By csiegber Date 2003-09-15 Time 14:17 Rev Time 0.00
Received By csiegber Date 2003-09-15 Time 14:17 Sent To B
Notes
2003-09-15 00:00:00TO JG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-18 Cont ID  
Sent By alange Date 2003-08-18 Time 13:16 Rev Time 0.00
Received By alange Date 2003-08-18 Time 13:17 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-13 Cont ID  
Sent By mmclean Date 2003-08-18 Time 10:38 Rev Time 0.00
Received By dbaxter Date 2003-08-13 Time 10:38 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-02-23 Cont ID  
Sent By pkrauss Date 2004-02-23 Time 15:31 Rev Time 0.25
Received By pkrauss Date 2004-02-23 Time 15:26 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-29 Cont ID  
Sent By csiegber Date 2004-02-13 Time 11:33 Rev Time 0.25
Received By rmcdouga Date 2003-08-29 Time 08:52 Sent To P
Notes
2003-08-29 00:00:00PROVISO
  
 RETURN AIR TRANSFER DUCTS ARE REQUIRED
 TO BE 1-1/2 TIMES THE CROSS SECTIONAL
 AREA OF THE SUPPLY DUCTS PER FBC (M)
 601.4.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-29 Cont ID  
Sent By rmcdouga Date 2003-08-29 Time 09:25 Rev Time 0.25
Received By rmcdouga Date 2003-08-29 Time 09:25 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-18 Cont ID  
Sent By dbaxter Date 2003-08-13 Time 10:38 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***