Plan Review Stops For Permit 03080609 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2003-10-27 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-27 |
Time |
15:40 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-10-27 |
Time |
15:40 |
Sent To |
|
|
Notes |
2003-10-27 00:00:00 | SEE PROVISO PREVIOUS REVIEW |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2003-10-23 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-27 |
Time |
15:12 |
Rev Time |
2.00 |
Received By |
sthyng |
Date |
2003-10-23 |
Time |
11:42 |
Sent To |
E |
|
Notes |
2003-10-23 00:00:00 | IMPACT FEES | | | | ***PROVISO*** | | | | SMOKE DETECTORS AND GFCI IN EXISTING | | HOUSE FBC3401.7.2. | | | | HURRICANE SHUTTERS ON SEPARATE PERMIT | | | | TO BT DESK TO RESTAMP ELECTRIC SHEETS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-10-21 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-22 |
Time |
14:14 |
Rev Time |
0.50 |
Received By |
sthyng |
Date |
2003-10-21 |
Time |
14:21 |
Sent To |
|
|
Notes |
2003-10-21 00:00:00 | *****CORRECTIONS****** | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | SEE PREVIOUS REVIEW - NONE OF THE ITEMS | | ADDRESSED EXCEPT FOR #13 AND #14. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-09-23 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-12 |
Time |
07:18 |
Rev Time |
1.50 |
Received By |
sthyng |
Date |
2003-09-23 |
Time |
16:49 |
Sent To |
|
|
Notes |
2003-09-23 00:00:00 | *****CORRECTIONS****** | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)PROVIDE AREA CALCULATIONS ON THE | | PLAN - EXISTING AND PROPOSED, NEW | | TOTAL. | | | | 2.)SIGN THE OWNER/AGENT LINE OF THE | | ENERGY CALCS, FBC13-101.2. | | | | 3.)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE | | STAMPED AND THE RECEIPT ATTACHED TO | | THE APPLICATION.233-5025 | | | | 4.)THE WINDOW AT THE BATH IS REQUIRED | | TO BE SAFETY GLASS, FBC2405.2. | | | | 5.)HTS16 CONNECTOR REQUIRES 16 NAILS. | | HTSM16 ALSO REQUIRES TITENS; IF YOU ARE | | GOING TO SPECIFY FASTENERS SPECIFY | | ALL FASTENERS.REFER TO SIMPSON | | 2003 CATALOG. | | | | 6.)FEES DUE (RADON, VALUE ADJUSTMENT). | | $135.98, SEE ATTACHED BZ231203. | | | | 7.)THE FLOOR PLAN DOES NOT MATCH THE | | SITE PLAN.THE ADDITION IS SHOWN AS 23' | | AND LINING UP WITH THE EX. HOUSE.IF IT | | HAS A DIFFERENT SETBACK, IT SHOULD | | EITHER BE SMALLER THAN THE EX. HOUSE OR | | OFFSET ON THE OPPOSITE SIDE.REVISE THE | | FOUNDATION PLAN (ON SHEET 2, LABELED | | AS FLOOR PLAN) AND FLOOR PLAN, SHEET 1. | | | | 8.)IMPACT PROTECTION REQUIRED | | FBC1606.1.4. | | | | 9.)PROVIDE WIND DESIGN INFORMATION ON | | THE PLAN, FBC1606.1.7. | | | | 10.) FIRESTOP REQUIRED, FBC705.3. | | | | 11.) ATTIC ACCESS REQUIRED FBC2309.6. | | | | 12.) PROVIDE TWO COPIES OF ALL PRODUCT | | APPROVALS. | | DOOR | | WINDOW | | IMPACT PROTECTION (SHUTTERS) | | | | 13.) A DOUBLE DOOR W/SIDELITE PRODUCT | | APPROVAL WAS SUBMITTED.THE PLAN SHOWS | | A SINGLE DOOR. | | | | 14.) MULLION PRODUCT APPROVALS WERE | | SUBMITTED.NO MULLIONS ARE SHOWN ON | | THE PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-03-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2004-03-02 |
Time |
12:50 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2004-03-02 |
Time |
12:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-10-23 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-10-23 |
Time |
14:30 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-10-23 |
Time |
14:09 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-23 |
Time |
11:43 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2003-08-27 |
Time |
16:04 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-10-27 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-27 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-27 |
Time |
15:12 |
Sent To |
B |
|
Notes |
2003-10-27 00:00:00 | TO ST DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-10-22 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-22 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-10-22 |
Time |
14:14 |
Sent To |
B |
|
Notes |
2003-10-22 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-14 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-14 |
Time |
12:44 |
Sent To |
M |
|
Notes |
2003-10-14 00:00:00 | TO PK BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-08-25 |
Time |
15:20 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-08-25 |
Time |
15:20 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-12 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-25 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
dbaxter |
Date |
2003-08-12 |
Time |
14:08 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2003-10-21 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-21 |
Time |
14:12 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-10-21 |
Time |
14:12 |
Sent To |
|
|
Notes |
2003-10-21 00:00:00 | NO MECHANICAL PLANS, N PER PK | | VOIDED MECHANICAL SUB PERMIT 03081429 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-09-12 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-14 |
Time |
12:44 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-09-04 |
Time |
14:16 |
Sent To |
B |
|
Notes |
2003-09-04 00:00:00 | DENIED: | | | | FORM 600B INDICATES NO COOLING OR | | HEATING SYSTEM.APPLICATION HAS A | | MECHANICAL PERMIT ASSIGNED.PLEASE | | INDICATE IF THE HVAC IS EXISTING OR IF | | A NEW SYSTEM IS TO BE INSTALLED. | | | | INDICATE DUCT & GRILLE SIZE FOR THE | | ADDITION. | | | | SHOW COMPLIANCE WITH 2001 FBC(M) 601.4, | | BALANCED AIR RETURN. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-09-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-08-27 |
Time |
16:13 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-09-03 |
Time |
12:32 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2003-08-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-25 |
Time |
10:56 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-12 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-08-18 00:00:00 | 8/18/03 DENIED, NEED TO BE 5FT FROM THE | | SIDE. CALLED OWNER FILE E MM |
|
|