Plan Review Details - Permit 03080459
Plan Review Stops For Permit 03080459
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-15 Cont ID  
Sent By jgomez Date 2003-09-15 Time 15:57 Rev Time 2.00
Received By jgomez Date 2003-09-15 Time 15:57 Sent To P
Notes
2003-09-15 00:00:00BUILDING REVIEW APPROVED WITH PROVISO:
 1-PROVIDE COMPLETE INFORMATION FOR STORM
 SHUTTERS UNDER A SEPARATE PERMIT.
 2-PROVIDE PRODUCT APPROVAL FOR ENTRY
 DOOR WITH SIDELITE ASSEMBLY AS SHOWN
 ON PLANS.
 3-WINDOW MULLION PRODUCT APPROVAL AND
 LETTER EXTENDING EXPIRATION DATE ARE
 BOTH EXPIRED. RESUBMIT CURRENT/RENEWED
 PRODUCT APPROVAL.
 4-PROVIDE PRODUCT APPROVAL FOR FIXED
 WINDOW ABOVE FAMILY ROOM SLIDING GLASS
 DOORS. SEE PLANS FOR SIZE REQUIRED.
 5-PROVIDE COMPLETE SOIL TEST REPORT THAT
 INCLUDES SOIL PREPARATION, FOOTING
 RECOMMENDATIONS AND SOIL BEARING
 CAPACITY. SEC. 1804.1.7 CITY
 AMENDMENTS TO FBC 2001.
 6-SPECIFY SAFETY GLASS WHERE REQUIRED.
 SEC. 2405.2 FBC 2001.
 7-THERE ARE SOME CONNECTORS THA NEED TO
 BE SPECIFIED. SEE PLANS. SECTION
 104.2.1.2 CITY AMENDMENTS TO FBC 2001.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-09-04 Cont ID  
Sent By csiegber Date 2003-09-10 Time 14:19 Rev Time 2.00
Received By jgomez Date 2003-09-03 Time 16:30 Sent To PC
Notes
2003-09-03 00:00:00BUILDING CHECKLIST:
 1-PROVIDE PRODUCT APPROVAL FOR:
 A)ENTRY DOOR WITH SIDELITE SINGLE
 ASSEMBLY AS SHOWN ON PLANS.
 B)OVERHEAD GARAGE DOORS.
 C)EXTERIOR SWING DOOR AT GARAGE.
 D)SINGLE HUNG WINDOWS.
 E)WINDOW MULLIONS.
 F)SLIDING GLASS DOORS.
 G)SLIDING GLASS DOORS WITH TRANSOM ABOVE
 SINGLE ASEMBLY AS SHOWN ON PLANS.
 H)ARCHED WINDOWS. SEE PLANS FOR SIZES
 AND SHAPES.
 I)ROOF TILE.
  
 2-PROVIDE COMPLETE INFORMATION FOR
 STORM SHUTTERS OR APPLY FOR A SEPARATE
 PERMIT.
 3-NEED TWO COPIES OF ENERGY CALCULATIONS
 WITH ENGINEER'S ORIGINAL SIGNATURE,
 SEAL, DATE ECT. CHAPTER 471 FLORIDA
 STATUTES.
 4-NEED COMPLETE SOIL TEST REPORT THAT
 INCLUDES FOOTING RECOMMENDATIONS AND
 SOIL BEARING CAPACITY.(ARCHITECT ALSO
 NEEDS THIS INFORMATION IN ORDER TO
 DESIGN THE FOUNDATION). SECTION
 1804.2.2 CITY AMENDMENTS TO FBC 2001.
 5-NEED RECEIPT OF PAID IMPACT FEES.
 6-NEED RECORDED NOTICE OF COMMENCEMENT.
 7-SHEET A-1: A)REVISE DETAIL #38.
 FOOTING TO BE 12" MINIMUM BELOW GRADE.
 SEC. 1804.1.3 FBC 2001. ALSO, INDICATE
 THE 4" MINIMUM ELEVATION ABOVE GRADE
 AS REQUIRED BY SEC. 1804.1.7 CITY
 AMENDMENTS TO FBC 2001. SEE COMMENTS
 ON DRAWINGS.
 8-SHEET A-2: A)SPECIFY SAFETY GLASS
 WHERE REQUIRED BY SEC. 2305.2 FBC.
 SEE PLANS.
 B)IDENTIFY ROOM SHOWN AT BOTTOM OF
 FAMILY ROOM AND BREAKFAST AREA.
 C)CLARIFY BEAMS SPECIFIED FOR COVERED
 PATIO ROOF . ARE THEY ROOF TRUSSES OR
 CONCRETE LINTELS. SEE FRAMING PLANS
 AND DETAILS.
 9-SHEET A-4: A)REVISE BUCK DETAILS. SEE
 SECTION 1707.4.4.2 FBC 2001.
 10-SPECIFY ANCHOR EMBEDMENT AND WASHER
 SIZE REQUIRED FOR GARAGE DOOR BUCK
 DETAIL. SEC. 104.2.1.2 CITY AMENDMENTS
 TO FBC 2001. SEE PLANS.
 11-SHEET A-5: A)CLARIFY DETAILS 12/A6
 AND 7/A6. THEY DON'T APPLY. SEE THE
 ELEVATION. ALSO, IS NOT CLEAR IF IT'S
 GOING TO BE WOOD TRUSSES OR CONCRETE
 LINTELS.
 B)THERE ARE SOME CONNECTORS THAT NEED
 TO BE SPECIFIED. SEE PLANS.
 12-SHEET A-6:
 A)CLARIFY DETAILS 1/A-6, 7/A-6 AND 12/A6
 THEY DON'T APPLY TO THIS SPECIFC
 CONSTRUCTION. SEE PLANS AND REVISE
 DETAILS AS REQUIRED TO MATCH PLANS.
 13-DETAIL 13/A6 NEEDS TO PROVIDE MORE
 INFORMATION. SEE PLANS.
  
 NOTE:
 PLEASE RETURN REVIEWED SET AFTER THE
 CORRECTIONS ARE DONE TO THE ORIGINAL
 CAD DRAWINGS. DON'T FORGET TO BRING
 BACK STAMPED AND APPROVED PLANS BY THE
 OTHER TRADES.
  
 14-PROVIDE GENERAL SPECIFICATIONS FOR
 FIREBLOCKING AT ALL CONCEALED SPACES.
 SEC. 2305 FBC 2001.
 15-PROVIDE NAILING DIAPHRAGM SHOWING
 THE NAILING ZONES. SEE SECTION
 2306 OF CITY AMENDMENTS TO FBC 2001.
 16-CLARIFY OWNERSHIP OF THIS PROPERTY.
 OWNER INFORMATION GIVEN ON BUILDING
 PERMIT APPLICATION DON'T MATCH
 INFORMATION ON OUR SYSTEM. CLARIFY.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-04-20 Cont ID  
Sent By jleahy Date 2004-04-20 Time 08:28 Rev Time 0.15
Received By jleahy Date 2004-04-20 Time 08:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-04-14 Cont ID  
Sent By jleahy Date 2004-04-14 Time 14:50 Rev Time 0.15
Received By jleahy Date 2004-04-14 Time 14:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-19 Cont ID  
Sent By csiegber Date 2004-04-13 Time 12:08 Rev Time 0.50
Received By btrobaug Date 2003-08-19 Time 13:35 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-04-13 Cont ID  
Sent By csiegber Date 2004-04-13 Time 12:08 Rev Time 0.00
Received By csiegber Date 2004-04-13 Time 12:08 Sent To E
Notes
2004-04-13 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 11:31 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 11:31 Sent To M
Notes
2004-02-13 00:00:00TO PK BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-10 Cont ID  
Sent By csiegber Date 2003-09-10 Time 14:19 Rev Time 0.00
Received By csiegber Date 2003-09-10 Time 14:19 Sent To B
Notes
2003-09-10 00:00:00TO JG DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-12 Cont ID  
Sent By dbaxter Date 2003-08-12 Time 13:55 Rev Time 0.00
Received By dbaxter Date 2003-08-12 Time 13:55 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-08 Cont ID  
Sent By mmclean Date 2003-08-12 Time 10:57 Rev Time 0.00
Received By alange Date 2003-08-08 Time 16:44 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2004-02-23 Cont ID  
Sent By pkrauss Date 2004-02-23 Time 14:53 Rev Time 0.25
Received By pkrauss Date 2004-02-23 Time 14:53 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-26 Cont ID  
Sent By csiegber Date 2004-02-13 Time 11:31 Rev Time 0.25
Received By pkrauss Date 2003-08-26 Time 12:43 Sent To P
Notes
2003-08-26 00:00:00PROVISO:
 PLEASE NOTE THE RETURN AIR CALCULATIONS
 WERE REVISED AS OF JUNE 30, 2003.
 PLEASE SHOW COMPLIANCE WITH THE
 FOLLOWING:
  
 BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-09-15 Cont ID  
Sent By kstevens Date 2003-09-15 Time 18:12 Rev Time 0.33
Received By kstevens Date 2003-09-15 Time 18:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-09-02 Cont ID  
Sent By jgomez Date 2003-09-15 Time 16:03 Rev Time 0.33
Received By kstevens Date 2003-09-02 Time 18:49 Sent To B
Notes
2003-09-02 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SANITARY RISER DIAGRAM DOES NOT RE-
 FLECT THE FLOOR PLAN. THE LAUNDRY SINK
 AND WASH MACHINE ARE NOT ACROSS FROM
 EACH OTHER. THE OPTIONAL BATHROOM HAS
 A TUB ON THE FLOOR PLAN AND A SHOWER ON
 THE RISER. THE RISER IS NOT DRAWN TO
 REFLECT THE LAYOUT OF THE HOUSE (REVERSE
 LAYOUT).
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-12 Cont ID  
Sent By alange Date 2003-08-08 Time 16:44 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***