Plan Review Stops For Permit 03080143 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-08-28 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-08-28 |
Time |
11:52 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-08-28 |
Time |
11:52 |
Sent To |
|
|
Notes |
2003-08-28 00:00:00 | PROVISO | | SEP PERMITS FOR HURRICANE SHUTTERS | | SUBMIT REVISION FOR S1 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-08-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-28 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-08-28 |
Time |
08:44 |
Sent To |
P |
|
Notes |
2003-08-19 00:00:00 | *****CORRECTONS****** | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2.)ALL EXTERIOR DOORS ARE GLAZED. | | ONE METHOD OF EGRESS ON THE FIRST FLOOR | | MUST BE PROVIDED, CANNOT BE SHUTTERED, | | FBC1005.4.5, 2003 AMENDMENT. | | | | 3.)SUBMIT PRODUCT APPROVALS FOR ALL | | GLAZING, DOORS, ROOF, MULLIONS,SHUTTERS. | | ANY PRODUCT APPROVALS NOT SUBMITTED | | BEFORE THE LAST REVIEW WILL REQUIRE | | SEPARATE PERMITS FOR THOSE ITEMS. | | | | 4.)DETAIL S1-38, THE BOTTOM OF | | FOUNDATIONS SHALL EXTEND NO LESS THAN | | 12" BELOW FINISH GRADE, FBC1804.1.3. | | | | 5.)DETAIL S3-12 ATTACHMENT CONFLICTS | | WITH THE USP 2003 CATALOG.NO UPLIFT | | IS SPECIFIED IN THE CATALOG WHEN 10DX | | 1 1/2 NAILS ARE USED.CHECK ALL | | ATTACHMENTS. | | | | 6.)FEES DUE; $20.44. | | | | 7.)PROVIDE A SOILS INVESTIGATION | | REPORT. | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-04-20 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2004-04-20 |
Time |
08:33 |
Rev Time |
0.15 |
Received By |
jleahy |
Date |
2004-04-20 |
Time |
08:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-04-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2004-04-14 |
Time |
14:45 |
Rev Time |
0.15 |
Received By |
jleahy |
Date |
2004-04-14 |
Time |
14:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-08-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-13 |
Time |
11:50 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-08-28 |
Time |
08:45 |
Sent To |
B |
|
Notes |
2003-08-28 00:00:00 | ************ NOTES REDLINED ********* | | | | SD MISSING IN ROOM BY FRONT DOOR NFPA-72 | | MISSING RECEPT ON COUNTER IN KITCHEN. | | 210.52C1 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-08-13 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-27 |
Time |
14:00 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-08-13 |
Time |
18:30 |
Sent To |
M |
|
Notes |
2003-08-13 00:00:00 | ************* UNSAT **************** | | | | 1)NOTE: PLEASE CORRELATE RISER AND NOTES | | FOR RISER. ONE SHOWS 225A, OTHER AT 200A | | CONDUCTORS ARE SHOWN FOR 225 AND PANEL | | IS SHOWN AS MLO.? | | | | 2)NOTE: PLEASE REVISE ALL CODES SHOWN | | ON PLANS TO 2002 NEC AS OF JULY 1ST, | | 2003. | | | | 3)NOTE: PLEASE SEE SUB PANEL, SHOWN AS | | 65A? PLEASE CORRECT AND CORRELATE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2004-04-13 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-04-13 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-04-13 |
Time |
11:50 |
Sent To |
E |
|
Notes |
2004-04-13 00:00:00 | TO BT DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2004-01-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-28 |
Time |
14:29 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-01-28 |
Time |
14:29 |
Sent To |
M |
|
Notes |
2004-01-28 00:00:00 | TO PK BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-27 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-27 |
Time |
14:00 |
Rev Time |
0.00 |
Received By |
dbaxter |
Date |
2003-08-27 |
Time |
14:00 |
Sent To |
E |
|
Notes |
2003-08-27 00:00:00 | TO DPALMER DESK. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
dbaxter |
Date |
2003-08-11 |
Time |
15:38 |
Rev Time |
0.00 |
Received By |
dbaxter |
Date |
2003-08-11 |
Time |
15:38 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-11 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-06 |
Time |
13:42 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-02-06 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-02-06 |
Time |
07:49 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-02-06 |
Time |
07:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-19 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-01-28 |
Time |
14:29 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-19 |
Time |
06:51 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-08-28 |
Time |
11:51 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-08-20 |
Time |
19:33 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|