Plan Review Details - Permit 03072438
Plan Review Stops For Permit 03072438
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-10 Cont ID  
Sent By rmcdouga Date 2003-09-10 Time 07:19 Rev Time 2.00
Received By rmcdouga Date 2003-09-10 Time 07:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-25 Cont ID  
Sent By csiegber Date 2003-09-08 Time 08:49 Rev Time 3.00
Received By rmcdouga Date 2003-08-25 Time 11:15 Sent To  
Notes
2003-08-25 00:00:00DENIED
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3)PROVIDE (2) CURRENT AND COMPLETE
 COPIES OF SBCCI OR METRO-DADE PRODUCT
 APPROVALS FOR:
 - HORIZONTAL SLIDING WINDOWS
  
 4) SUBMIT THE MANUFACTURER'S SPECS. AND
 U.L.LISTING INFORMATION FOR THE ONE HOUR
 FIRE RATED GLASS BLOCK.
  
 5) REVISE STUCCO NOTES ON A6. HIGH RIB
 METAL LATH IS REQUIRED TO BE FASTENED AT
 EACH RIB (4"OC) PER ASTM C 1063. SEE
 FBC 2504.2.2.
  
 6) SUBMIT A LINTEL SCHEDULE.
  
 7) PROVIDE (2) PRODUCT APPROVALS, KEY
 PLANS AND INSTALLATION SCHEDULES
 INDICATING THE SPECIFIC TYPES OF ANCHORS
 TO BE USED FOR STORM PANELS. SPECIFY THE
 MOUNTING TYPE AND CONNECTION TYPE.
  
 8) REVISE THE BUCK DETAIL ON A8. THE
 FRAMES ARE REQUIRED TO BE FASTENED
 THROUGH THE 1X BUCKS INTO THE SUBSTRATE
 PER FBC 1707.4.4.2.
  
 9) THE FBC 11-4.23.2 REQUIRES AT LEAST
 ONE BATH ROOM WITH A DOOR THAT HAS A 29
 INCH CLEAR OPENING. IF A FULL BATH IS
 PROVIDED AT GRADE LEVEL, IT IS REQUIRED
 TO COMPLY.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-08-13 Cont ID  
Sent By alange Date 2003-08-05 Time 13:31 Rev Time 0.50
Received By btrobaug Date 2003-08-13 Time 10:33 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-09-08 Cont ID  
Sent By csiegber Date 2003-09-08 Time 08:49 Rev Time 0.00
Received By csiegber Date 2003-09-08 Time 08:49 Sent To B
Notes
2003-09-08 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-05 Cont ID  
Sent By csiegber Date 2003-09-05 Time 08:58 Rev Time 0.00
Received By csiegber Date 2003-09-05 Time 08:57 Sent To B
Notes
2003-09-05 00:00:00TO RM DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-05 Cont ID  
Sent By alange Date 2003-08-05 Time 13:31 Rev Time 0.00
Received By alange Date 2003-08-05 Time 13:30 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-08-01 Cont ID  
Sent By mmclean Date 2003-08-05 Time 09:55 Rev Time 0.00
Received By alange Date 2003-08-01 Time 10:28 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-08-19 Cont ID  
Sent By btrobaug Date 2003-08-13 Time 17:33 Rev Time 0.25
Received By pkrauss Date 2003-08-19 Time 07:28 Sent To P
Notes
2003-08-19 00:00:00PROVISO:
 2001 FBC(M) 601.4:
 BALANCE AIR RETURN - RETURN TRANSFER
 SHALL BE 1 1/2 TIMES THE CROSS SECTIONAL
 AREA (SQ INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM IT'S SERVING & THE
 DOOR HAVING AN UNRESTRICTED 1" UNDERCUT.
  
 ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-08-20 Cont ID  
Sent By pkrauss Date 2003-08-19 Time 07:32 Rev Time 0.33
Received By jleech Date 2003-08-20 Time 19:30 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-05 Cont ID  
Sent By alange Date 2003-08-01 Time 10:28 Rev Time 0.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***