Plan Review Stops For Permit 03072430 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-09-18 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2003-09-18 |
Time |
08:52 |
Rev Time |
1.50 |
Received By |
lsmith |
Date |
2003-09-18 |
Time |
08:51 |
Sent To |
|
|
Notes |
2003-09-18 00:00:00 | **************PROVISO******************* | | | | 1. PROPERTY LOCATED IN AO FLOOD ZONE | | AN ELEVATION CERTIFICATE WILL BE | | REQUIRED BEFORE C/O. | | 2. PRODUCT APPROVALS FOR WINDOW | | MULLENS'HAS TO BE SUBMITTED BEFORE | | INSTALLATION OF WINDOWS. | | 3. SUBMIT PRODUCT APPROVAL FOR GLASS | | BLOCK | | 4. KEY PLAN FOR SHUTTERS IS STILL | | INCORRECT. RESUBMIT CORRECTED KEY PLAN. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-08-21 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-17 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
lsmith |
Date |
2003-08-21 |
Time |
13:26 |
Sent To |
|
|
Notes |
2003-08-21 00:00:00 | *************FAILED******************* | | | | 1. PROPERTY LOCATED IN AO FLOOD ZONE. | | AN ELEVATION CERTIFICATE IS REQUIRED | | BEFORE C/O. | | | | 2. PLANS MUST BE TAKEN TO PBC, IMPACT | | FEES PAID & RESUBMITTED TO CITY WITH | | PAID RECEIPT AND PLANS STAMPED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 3. NO PRODUCT APPROVALS HAVE BEEN | | SUBMITTED FOR THE SINGLE HUNG WINDOWS & | | MULLINS. | | | | 4. THE KEY PLAN & STORM PANEL SCHEDULE | | DOES NOT AGREE WITH HOUSE PLANS. | | CORRECT & RESUBMIT. NOTE NEW EXPIRATION | | DATE OF PRODUCT APPROVALS FOR STORM | | PANELS PER WEBB SITE IS 7/31/03. | | | | 5. HIGHLIGHT TYPE OF GLASS BLOCK BEING | | INSTALLED ON PRODUCT APPROVALS. | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2004-03-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-03-10 |
Time |
07:07 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-03-10 |
Time |
07:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2004-03-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-03-05 |
Time |
11:05 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-03-05 |
Time |
11:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2004-02-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-02-23 |
Time |
12:08 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-02-23 |
Time |
12:07 |
Sent To |
|
|
Notes |
2004-02-23 00:00:00 | ******* NOTES REDLINED. ***** | | | | 1)NOTE: PLEASE SEE LT REQ'D ON PATIO. | | 210.70, LS 101 5-8 | | | | 2)NOTE: METERCAN SHOWN AT 150A, PLEASE | | SEE THAT 150A METERCAN IS NOT A COMMON | | SIZE. 100A, 200, 320,400,600A ETC. | | | | 3)NOTE: PLEASE SEE 210.52D , RECETP | | TO BE A MAX OF 3'FROM SINK IN MASTERBATH | | | | 4)NOTE: PLEASE SEE SERVICE ENT CONDUCTOR | | -S SHOWN AS 2/0'S FOR 200A SERV,?? | | | | PLANS TO BE REVISED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-08-13 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-07 |
Time |
07:54 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-08-13 |
Time |
06:22 |
Sent To |
M |
|
Notes |
2003-08-13 00:00:00 | ***** NOTES REDLINED ********** | | | | 1)NOTE: PLEASE SEE MISSING RECEPTS ALONG | | KITCHEN COUNTERSPACE 210.52C1 | | | | 2)NOTE: PLEASE SEE NOTE FOR ALL RECEPT | | SPACING TO BE PER 210.52 | | | | 3)NOTE: PLEASE SEE GFI RECEPT IN MASTER | | BATH TO BE W/IN 3' OF LAV. 210.52D | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRCIAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
F |
Date |
2003-09-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-17 |
Time |
15:53 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-17 |
Time |
15:53 |
Sent To |
B |
|
Notes |
2003-09-17 00:00:00 | TO LS DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-07 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-07 |
Time |
07:54 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-07 |
Time |
07:54 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-08-06 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-06 |
Time |
10:59 |
Sent To |
|
|
Notes |
2003-08-06 00:00:00 | PUT WITH ORIGONAL PLANS IN ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-08-01 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-01 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-01 |
Time |
11:49 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-13 |
Time |
06:22 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-14 |
Time |
12:44 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-08-20 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-14 |
Time |
12:44 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-08-20 |
Time |
17:32 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-01 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|