Plan Review Details - Permit 03072336
Plan Review Stops For Permit 03072336
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-08-21 Cont ID  
Sent By kstevens Date 2003-08-25 Time 15:47 Rev Time 0.00
Received By hpiskura Date 2003-08-21 Time 14:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By dpalmer Date 2003-08-25 Time 15:31 Rev Time 0.50
Received By dpalmer Date 2003-08-25 Time 15:31 Sent To  
Notes
2003-08-25 00:00:00******** NONE ***********
  
 PLEASE SUBMIT SEPARATE PLANS AND
 ELECTRICAL PERMIT APPLICATION FOR
 ELECTRICAL WORK.
 NO REVIEW FOR THIS APPLICATION.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-08-21 Cont ID  
Sent By dbaxter Date 2003-08-13 Time 10:46 Rev Time 1.25
Received By dpalmer Date 2003-08-21 Time 12:30 Sent To  
Notes
2003-08-21 00:00:00**************** UNSAT ***************
  
 1)NOTE: PLEASE SEE RISER FOR TENNIS CTS.
 PLEASE CLARIFY AND SHOW HOW EXIST 100A
 PANEL IS BEING FED? SHOWS 400A DISC AND
 THAT APPEARS TO FEED SOMETHING ELSE?
  
 2)NOTE: PLEASE PROVIDE ENGINEERING UNDER
 FBC FOR NEW LT POLES. 140MPH
  
 3)NOTE: PLEASE SEE EXISTING SERVICE FOR
 PRESS BOX/BATHS. PLEASE SEE LINE AND
 LOADS IN SAME ENCLOSURE, ETC ETC
 LOAD CALCS INCOMPLETE, PANEL SCHEDULE
 AND RISER DIAGRAM DO NOT CORRELATE.
 SHOWS 200A AND 100A ETC. 215.5/240/230
 ETC. PLEASE SEE CHAPTER 34 OF FBC FOR
 BRINGING EXIST ELEC UP TO CODE.
 4)NOTE: PLEASE SEE RECEPTS IN BATHS TO
 BE GFI. 210.8
  
 PLEASE SEE COMMENTS FROM OTHER REVIEWERS
 THAT MAY AFFECT ELECTRICAL PLANS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE NAY QUESTIONS,
 PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2003-08-18 Cont ID  
Sent By mamini Date 2003-08-18 Time 10:06 Rev Time 1.00
Received By mamini Date 2003-08-18 Time 10:06 Sent To  
Notes
2003-08-18 00:00:00PASSED WITH PROVISOS:
 1. POLLUTION / EROSION PLANS MUST BE
 INSTALLED IN FIELD PRIOR TO ANY EARTH/
 CONSTRUCTION WORK.
 IF ANY QUESTION PLEASE CONTACT 805-6723
 MOHAMMAD R. AMINI

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-11-24 Cont ID  
Sent By mcarsill Date 2003-11-24 Time 16:12 Rev Time 0.00
Received By mcarsill Date 2003-11-24 Time 16:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-08-19 Cont ID  
Sent By nmccray Date 2003-08-19 Time 16:03 Rev Time 0.00
Received By nmccray Date 2003-08-19 Time 16:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-11-18 Cont ID  
Sent By csiegber Date 2003-11-18 Time 10:17 Rev Time 0.00
Received By csiegber Date 2003-11-18 Time 10:17 Sent To  
Notes
2003-11-18 00:00:00TO COMM BD#12

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-13 Cont ID  
Sent By dbaxter Date 2003-08-13 Time 10:46 Rev Time 0.00
Received By dbaxter Date 2003-08-13 Time 10:46 Sent To E
Notes
2003-08-13 00:00:00TO COMM. BD. #14.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-31 Cont ID  
Sent By alange Date 2003-07-31 Time 08:45 Rev Time 0.00
Received By alange Date 2003-07-31 Time 08:45 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2003-08-26 Cont ID  
Sent By lsmith Date 2003-08-26 Time 07:42 Rev Time 0.00
Received By lsmith Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status N Date 2003-08-25 Cont ID  
Sent By kstevens Date 2003-08-25 Time 15:47 Rev Time 0.50
Received By kstevens Date 2003-08-25 Time 15:46 Sent To B
Notes
2003-08-25 00:00:00NO PLUMBING REVIEW, SUBMIT PLANS AND
 SEPARATE APPLICATION FOR PLUMBING.

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-08-22 Cont ID  
Sent By kstevens Date 2003-08-22 Time 10:05 Rev Time 1.00
Received By kstevens Date 2003-08-22 Time 10:05 Sent To  
Notes
2003-08-22 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT P-1 SANITARY RISER DIAGRAM, THE
 DRINKING FOUNTAINS AND THE URINAL ARE
 NOT VENTED. SECTION 901.2.1
 2) PER TABLE 403.1 A SERVICE SINK IS
 REQUIRED.
 3) FLOORS OF SANITARY FACILITIES SHALL
 BE CONSTRUCTED OF CONCRETE OR OTHER NON-
 ABSORBENT MATERIALS, SHALL HAVE A SMOOTH
 SLIP-RESISTANT FINISH, AND SLOP TO FLOOR
 DRAINS. - FLOOR DRAINS REQUIRED FOR
 HOSEING DOWN TOILET ROOMS. SEC. 403.8.3
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-12 Cont ID  
Sent By ajones Date 2003-08-12 Time 15:47 Rev Time 0.25
Received By ajones Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved