Plan Review Details - Permit 03072250
Plan Review Stops For Permit 03072250
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-09-08 Cont ID  
Sent By lsmith Date 2003-09-08 Time 12:34 Rev Time 0.50
Received By lsmith Date 2003-09-08 Time 12:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-12 Cont ID  
Sent By kstevens Date 2003-09-06 Time 14:31 Rev Time 0.75
Received By lsmith Date 2003-08-12 Time 11:19 Sent To  
Notes
2003-08-12 00:00:00*********FAILED BUILDING**************
  
 1. SHOW DETAILS FOR EQUIPMENT ANCHORING
 ON PLANS.
  
 2. ALL POOL TO COMPLY WITH FBC 2001
  
 3. SHOW METHOD OF PROTECTING THE POOL
 FROM WINDOWS & DOORS HAVING ACCESS TO
 POOL AREA PER 424.2.171 THRU 424.2.17.1.
 424.2.17.1.14.
  
 4. SUBMIT CONTRACT TO VERIFY VALUE OF
 CONTRACT FOR PERMITING FEES CALC.
  
  
 ANY QUESTIONS PLEASE CALL:
 LEA SMITH, BUILDING PLANS EXAMINER
 805-6713

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-08-26 Cont ID  
Sent By dpalmer Date 2003-08-26 Time 09:34 Rev Time 0.33
Received By dpalmer Date 2003-08-26 Time 09:29 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2003-08-11 Cont ID  
Sent By csiegber Date 2003-08-20 Time 16:51 Rev Time 0.33
Received By dpalmer Date 2003-08-11 Time 20:34 Sent To B
Notes
2003-08-11 00:00:00*************** UNSAT ******************
  
 1)NOTE; PLEASE SUBMIT COMPLETED PLANS
 FOR REVIEW. THERE IS NO ELECTRICAL
 WIRING DIAGRAM SHOWN? GROUNDING AND
 WIRING PER NEC 680. PLEASE ALSO SEE FBC
 FOR TC. REQ'D.
 PLEASE SEE PLUMB REVIEW COMMENTS.
 PLEASE SUBMIT ALL INFORMATION FOR REVIEW
 PLEASE ALSO NOTE, THERE MAY BE OTHER
 COMMENTS WHEN PLANS ARE SUBMITTED FOR
 REVIEW.
  
 IF THERE ARE ANY QUESTIONS, PLEASE CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-20 Cont ID  
Sent By csiegber Date 2003-08-20 Time 16:51 Rev Time 0.00
Received By csiegber Date 2003-08-20 Time 16:50 Sent To E
Notes
2003-08-20 00:00:00TO DP DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-29 Cont ID  
Sent By mmclean Date 2003-08-04 Time 10:07 Rev Time 0.00
Received By alange Date 2003-07-29 Time 16:30 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-09-06 Cont ID  
Sent By kstevens Date 2003-09-06 Time 14:31 Rev Time 0.50
Received By kstevens Date 2003-09-06 Time 14:31 Sent To B
Notes
2003-09-06 00:00:00 
  
  
 FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED.

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-08-09 Cont ID  
Sent By dpalmer Date 2003-08-26 Time 09:34 Rev Time 1.00
Received By kstevens Date 2003-08-09 Time 07:09 Sent To E
Notes
2003-08-09 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-5. (ADD TO NOTES)
 3) FBC-2001 SEC 424.2.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION INLETS. (DETAIL)
 4) FBC-2001424.2.6.6.2 SHOW COMPLIANCE
 WITH ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL OR ADD NOTE)(SUBMITTAL)
 5) FBC-2001424.2.6.6.3 (1,2,3) ENTRAP-
 MENT AVOIDANCE. (DETAIL)
 6) FBC-2001424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER. (DETAIL)
 7) FBC-2001424.2.7.1 POOL CIRCULATING
 PUMPS SHALL BE EQUIPPED ON THE INLET
 SIDE WITH AN APPROVED TYPE HAIR AND LINT
 STRAINER WHEN USED WITH A PRESSURE FIL-
 TER. (DETAIL) (NOTES)
 8) FBC-2001 424.2.7.2 PUMPS AND EQUIP-
 MENT SHALL BE MOUNTED ON A SUBSTANTIAL
 BASE IN A MANNER THAT WILL ELIMINATE
 STRAIN ON PIPING. SLAB SHALL BE A NOMIN-
 AL 4" THICK. (DETAIL)
 9) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 10) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 11) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
 12) FBC-2001 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL)
 13) FBC-2001 424.2.14.2 WATER RETENTION,
 PROVIDE A POSITIVE MEANS OF RETAINING
 WATER IN THE HEATER WHEN PUMP IS SHUT
 OFF. (MANUFACTURE CUT SHEETS SUBMITTAL)
 14) FBC-2001 424.2.14.4 CONNECTIONS, ALL
 WATER HEATING EQUIPMENT SHALL BE INSTAL-
 LED WITH FLANGES OR UNION CONNECTIONS
 ADJACENT TO THE HEATER. (ADD TO NOTES)
 15) FBC02001 424.2.15 GAS PIPING SHALL
 COMPLY WITH FBC FUEL GAS. SEPARATE PLANS
 AND PERMIT REQUIRED. (NOTES)
 16) SUBMIT A PIPING SCHEMATIC SHOWING
 ALL PIPE SIZES, VALVES, PUMP, FILTER,
 HEATER, BYPASS, VACUUM, SKIMMER, MAIN
 DRAINS FOR POOL & SPA, RETURN LINES ECT.
 17) TIME CLOCK SHALL BE INSTALLED PER
 SECTION 13-612.1.ABC.2.3.3 ENERGY CODE.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date 2003-08-04 Cont ID  
Sent By alange Date 2003-07-29 Time 16:30 Rev Time 0.00
Received By mmclean Date   Time   Sent To P
Notes
***NONE***