Plan Review Stops For Permit 03072132 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-10-06 |
Time |
13:43 |
Rev Time |
1.00 |
Received By |
sthyng |
Date |
2003-10-06 |
Time |
13:43 |
Sent To |
|
|
Notes |
2003-10-06 00:00:00 | ****PROVISO**** | | 1.) SEPARATE PERMIT REQUIRED FOR | | BAHAMA SHUTTERS | | | | 2.)LIVE LOAD REQUIREMENTS FOR BOTTOM | | CHORD OF TRUSSES - 10 FOR ATTICS WITHOUT | | STORAGE, 30 FOR ATTICS WITH STORAGE | | FBC TABLE 1604.1. | | | | 3.)ATTIC ACCESS REQUIRED, FBC2309.6. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-09-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-03 |
Time |
09:17 |
Rev Time |
2.50 |
Received By |
sthyng |
Date |
2003-09-17 |
Time |
10:30 |
Sent To |
|
|
Notes |
2003-09-17 00:00:00 | *****CORRECTIONS****** | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEE ATTACHED NOTICE IN REGARDS TO | | FS553.80(2)(B). | | | | 2.)ADDITIONAL PERMITS REQUIRED. | | | | 3.)FEES DUE, $2.16 (RADON), BZ230486 | | ATTACHED.PAY AT CASHIER. | | | | 4.)SEE PREVIOUS CORRECTION LIST, ITEM | | 7.NOTE THE MINIMUM ELEVATION ON THE | | PLAN.A SURVEY WAS SUBMITTED, BUT IT | | WAS FOR A COMMERCIAL BUILDING LOCATED ON | | MEADOW PARK LOT 8 BLOCK 9. | | | | 5.)SEE PREVIOUS CORRECTION LIST, #9. | | WINDOWS G, D, AND E ARE 3'1 X 3'1. THIS | | SIZE DOES NOT COMPLY WITH FBC1005.4 | | REQUIREMENTS FOR EMERGENCY EGRESS. | | | | 6.)PRODUCT APPROVALS APPROVED FOR: | | EXTERIOR DOOR | | SINGLE HUNG IMPACT WINDOW | | ROOF TILE | | | | THE PRODUCT APPROVAL FOR THE GARAGE DOOR | | WAS ILLEGIBLE.SUBMIT 2 LEGIBLE COPIES. | | | | PRODUCT APPROVALS FOR THE BAHAMA | | SHUTTERS AND THE MULLIONS WERE REQUESTED | | BUT NOT SUBMITTED. | | | | PRODUCT APPROVALS MAY BE AVAILABLE | | ONLINE AT WWW.MIAMIDADE.GOV (FIND A | | DEPARTMENT, BUILDING CODE COMPLIANCE, | | PRODUCT CONTROL, SEARCH APPROVED | | PRODUCTS). | | | | 7.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED.THE NOC PROVIDED | | IS NOT SIGNED OR RECORDED. | | | | 8.)WHEN RESUBMITTING, REPLACE SHEETS | | WHICH HAVE BEEN CHANGED.OLD SHEETS | | ARE TO BE SUBMITTED SEPARATELY.THERE | | SHOULD BE TWO COMPLETE COLLATED PLAN | | SETS WITH THE MOST CURRENT REVISION OF | | EACH SHEET IN THAT SET.ALL CHANGES ARE | | TO BE CLOUDED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-08-14 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-16 |
Time |
07:11 |
Rev Time |
2.50 |
Received By |
sthyng |
Date |
2003-08-14 |
Time |
16:06 |
Sent To |
|
|
Notes |
2003-08-14 00:00:00 | *****CORRECTIONS****** | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)ADDITIONAL PERMITS REQUIRED. | | | | 2.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED. | | | | 3.)ENERGY CALCS REQUIRED, FBC13-103.1. | | 2.WHEN RESUBMITTING, SIGN THE OWNER/ | | AGENT LINE OF THE ENERGY CALC. | | | | 4.)FEES DUE ($2.16, RADON) | | | | 5.)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE | | STAMPED AND THE RECEIPT ATTACHED TO THE | | PERMIT APPLICATION. | | | | 6.)IMPROVEMENTS OF OVER 50% MUST | | COMPLY WITH FBC3401.7.2.6. | | | | 7.)THIS PROPERTY IS IN A FLOOD ZONE | | AND MUST COMPLY WITH CITY OF WEST PALM | | BEACH MUNICIPAL CODE 94-546(B)(1). | | PROVIDE A SURVEY AND FLOOD ELEVATION | | CERTIFICATE FOR THIS PROPERTY.SHOW | | THE PROPOSED ELEVATION FOR THE ADDITION. | | | | 8.)ROOF FRAMING PLAN REFERS TO | | ATTACHMENT 2, NOT ON THE CONNECTION | | SCHEDULE. | | | | 9.)ALL WINDOWS ARE SHOWN AS FIXED | | IMPACT GLASS ON THE SCHEDULE (A1). | | ALL BEDROOMS ARE REQUIRED TO HAVE | | EMERGENCY EGRESS, FBC1005.4. | | | | 10.) A-43, CONTINUOUS GABLE ENDWALL | | REINFORCEMENT, REFERS TO 110 MPH.CITY | | OF WPB IS 140MPH 3 SECOND GUST. | | | | 11.) PLYWOOD SHEATHING NAILING SCHEDULE | | (A3) COMPLIES WITH THE CITY OF WPB | | AMENDMENTS TO THE FBC, TABLE 2306.1, | | BUT THE WALL SECTION DOES NOT (A-A3). | | | | 12.) BOTTOM OF FOOTING MUST BE MINIMUM | | OF 12" BELOW GRADE, FBC1804.1.3.SHOW | | ON WALL SECTION. | | | | 13.)FLOOR ELEVATION IS REQUIRED TO BE | | A MINIMUM OF 4" ABOVE FINISH GRADE, | | CITY OF WPB AMENDMENTS TO THE FBC | | 1804.1.7.REVISE WALL SECTION. | | | | 14.) A1, FLOOR PLAN REMODEL, AT THE | | NEW WIC, SHOWS DETAIL 1-A4.NOT ON | | PLAN. | | | | 15.)FIRESTOP REQUIRED, FBC705.3. | | | | 16.)SUBMIT TWO LEGIBLE COPIES OF | | PRODUCT APPROVALS: | | GARAGE DOOR | | BAHAMA SHUTTES | | WINDOWS | | MULLIONS | | ROOF TILE (MAY BE SUBMITTED W/ROOF | | PERMIT APPLICATION) | | | | 17.)PROVIDE A SOILS INVESTIGATION | | REPORT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-09-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-09-05 |
Time |
19:20 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-09-05 |
Time |
18:56 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-08-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-04 |
Time |
16:48 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-08-04 |
Time |
09:27 |
Sent To |
P |
|
Notes |
2003-08-04 00:00:00 | PLEASE PROVIDE THE FOLLOWING | | INFORMATION,MAKE NECESSARY CHANGES TO | | PLANS AND RESUBMIT FOR REVIEW. | | | | 1} PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW EQUIPMENT BEING INSTALLED. | | MAINS/PANELS/BREAKERS MUST BE RATED FOR | | THE AVAILABLE FAULT CURRENT PER 110-9. | | | | 2} DRYER VA IN THE LOAD CALCULATION MUST | | COMPLY WITH 210.18(5000 VA). | | | | 3} THE AIR HANDLER IS SHOWN AS 10 KW ON | | THE SCHEDULE BUT CALCULATED @ 7400.IT | | WAS ALSO TAKEN AGAIN IN THE DEMAND FOR | | OTHER LOADS.PLEASE SEE 220.3(B).(100%). | | | | 4} PLEASE LIST THE REQ`D BATH(S) | | CIRCUIT(S). PER 210-11-C-3 | | MUST BE 20A AND #12AWG. | | | | 5} PLEASE INCLUIDE SMALL APPLIANCE | | CIRCUITS IN CALC.PER210.16(A). | | | | 6} DINNING RM RECEPTACLE SPACING TO | | COMPLY WITH 210.52(A). SEE REVIEWD SET | | OF PLANS. | | | | 7} GARAGE RECEPTACLES TO COMPLY WITH | | 210.8(A)(2).GFI. | | | | 8} ADD A SMOKE DETECTOR IN THE HALL | | OUTSIDE THE BEDROOMS PER 24.3.4 | | NFPA-101. | | | | 9} FIXTURES IN THE CLOSETS MUST COMPLY | | 410.8 | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-10-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-03 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-03 |
Time |
09:17 |
Sent To |
B |
|
Notes |
2003-10-03 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-09-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-15 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-15 |
Time |
16:03 |
Sent To |
B |
|
Notes |
2003-09-15 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-09-04 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-04 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-04 |
Time |
16:48 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-30 |
Time |
15:59 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-30 |
Time |
15:59 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-07-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-07-30 |
Time |
12:03 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-28 |
Time |
15:46 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-09-16 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-09-16 |
Time |
07:10 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-09-16 |
Time |
07:10 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2003-08-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-09-05 |
Time |
19:20 |
Rev Time |
0.20 |
Received By |
pkrauss |
Date |
2003-08-12 |
Time |
06:31 |
Sent To |
B |
|
Notes |
2003-08-12 00:00:00 | DENIED: | | | | PLEASE CLARIFY RETURN AIR.PLANS DO NOT | | INDICATE DUCT SIZE.RETURN OR TRANSFER | | AIR REQUIRED FROM BEDROOM AREAS AS PER | | 2001 FBC(M) 601.4. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-08-07 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-12 |
Time |
06:31 |
Rev Time |
0.25 |
Received By |
kstevens |
Date |
2003-08-07 |
Time |
17:07 |
Sent To |
|
|
Notes |
2003-08-07 00:00:00 | PASSED/PROVISO | | | | VENT REQUIRED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-07-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-28 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|