Plan Review Details - Permit 03071963
Plan Review Stops For Permit 03071963 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-09-02 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-09-02 |
Time |
17:47 |
Rev Time |
1.50 |
Received By |
sthyng |
Date |
2003-09-02 |
Time |
17:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-08-14 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-09-02 |
Time |
13:13 |
Rev Time |
3.00 |
Received By |
sthyng |
Date |
2003-08-14 |
Time |
11:43 |
Sent To |
|
|
Notes |
2003-08-14 00:00:00 | ******CORRECTIONS****** | | | | SAMANTHA THYNG, BUILDING PLANS EXAMINER | | [email protected] | | | | 1.)SEPARATE PERMITS REQUIRED. | | | | 2.)PROVIDE AREA CALCULATIONS ON THE | | PLAN (EXISTING, PROPOSED, NEW TOTAL). | | | | 3.)ADDITIONAL FEES DUE ($3.56, RADON). | | | | 4.)IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY.THE PLANS MUST BE STAMPED | | AND THE RECEIPT ATTACHED TO THE | | APPLICATION.233-5025 | | | | 5.)ENERGY CALCS REQUIRED, FBC13-103.1. | | 2.WHEN RESUBMITTING, SIGN THE OWNER/ | | AGENT LINE OF THE ENERGY CALC FBC13-103. | | 1.2. | | | | 6.)SUBMIT TWO COPIES OF PRODUCT | | APPROVALS FOR THE ROOF INSULATION. | | | | 7.)FIRESTOP REQUIRED FBC705.3. | | | | 8.)FLOOR JOISTS TO COMPLY WITH FBC | | 2304.3.4. | | | | 9.)PROVIDE UPLIFT INFORMATION FOR THE | | ROOF FRAMING. | | | | 10.) PROVIDE A SURVEY FOR THIS PROPERTY. | | | | 11.) FINISHED FLOOR ELEVATION SHALL | | HAVE THE LOWEST FLOOR ELEVATED TO 6" | | ABOVE THE BASE FLOOD ELEVATION, CITY | | OF WEST PALM BEACH MUNICIPAL CODE (FLOOD | | ZONE). | | | | 12.) PROVIDE A SOILS INVESTIGATION | | REPORT. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-08-04 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-30 |
Time |
16:19 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2003-08-01 |
Time |
17:44 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-09-02 |
|
|
Cont ID |
|
Sent By |
sthyng |
Date |
2003-09-02 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
sthyng |
Date |
2003-09-02 |
Time |
13:13 |
Sent To |
B |
|
Notes |
2003-09-02 00:00:00 | TO ST DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-30 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-30 |
Time |
16:19 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-07-25 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-07-30 |
Time |
12:29 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-25 |
Time |
09:48 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-09 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-08-05 |
Time |
08:59 |
Rev Time |
0.50 |
Received By |
hmoser |
Date |
2003-08-09 |
Time |
09:49 |
Sent To |
B |
|
Notes |
2003-08-09 00:00:00 | PASS/PRIVISO | | RETURN AIR IN MASTER BEDROOM MUST BE 9IN | | REFER TO SECTION 601.4 FLORIDA BUILDING | | CODE (M) | | PLAN REVIEW BY HAROLD MOSER | | (561)805-6732 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-08-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2003-08-04 |
Time |
07:52 |
Rev Time |
0.50 |
Received By |
kstevens |
Date |
2003-08-05 |
Time |
08:15 |
Sent To |
M |
|
Notes |
2003-08-05 00:00:00 | PASSED/PROVISO - REVISION REQUIRED - | | TABLE 906.1 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-07-30 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-25 |
Time |
09:49 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
|