Plan Review Details - Permit 03071184
Plan Review Stops For Permit 03071184
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-27 Cont ID  
Sent By rbrown Date 2003-08-27 Time 11:01 Rev Time 0.00
Received By rbrown Date 2003-08-27 Time 11:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-08-08 Cont ID  
Sent By dbaxter Date 2003-08-26 Time 10:46 Rev Time 0.00
Received By rbrown Date 2003-08-08 Time 14:58 Sent To  
Notes
2003-08-08 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 805 6716
 E-MAIL: [email protected]
  
 FBC = FLORIDA BUILDING CODE 2001
 FBC*= FLORIDA BUILD'G CODE (CITY AMEND)
  
 1) THE NOTICE OF COMMENCEMENT SHALL BE
 RECORDED AT PALM BEACH COUNTY COURTHOUSE
 AND A COPY SUBMITTED TO THIS OFFICE
 BEFORE A PERMIT CAN BE ISSUED.BLANK
 FORMS ARE AVAILABLE FROM THIS OFFICE.
  
 2) FBC* 11-4.13.6 MANEUVERING CLEARANCES
 AT DOORS.ON THE PULL SIDE OF DOOR 5,
 THE LEADING EDGE OF THE DOOR SHALL BE AT
 LEAST 18" CLEAR OF THE ADJACENY WALL
 (REF: FIG 25A)
  
 3) FBC 11-4.24.6BREAK ROOM SINK.ANY
 HOT WATER OR DRAIN PIPES EXPOSED UNDER
 THE SINK SHALL BE INSULATED OR OTHERWISE
 CONFIGURED TO PROTECT AGAINST CONTACT.
 ANNOTATE THE PLANS TO DEMONSTRATE
 COMPLIANCE.
  
 4) FBC* 104.2.1CONSTRUCTION OF NEW
 BREAK ROOM.THE KEY PLANS SHOWS THAT
 THE CONSTUCTION OF THE WALL TO FORM THE
 NEW BREAK ROOM WILL RESULT IN A NEW ROOM
 BEING FORMED ADJACENT THE BREAK ROOM.
 NO MEANS OF ENTRY/EGRESS IS SHOWN FOR
 THE NEW ROOM.IS THIS ROOM STILL PART
 OF THE SAME TENANCY AND WHAT IS THE
 ROOM USE?PLEASE CLARIFY.
  
 5) IF NEW PLAN SHEETS ARE REQUIRED, IN
 ORDER TO ADDRESS THE ABOVE COMMENTS, THE
 OLD SHEETS SHALL BE REMOVED AND THE NEW
 SHEETS INSERTED.ONE COPY OF EACH OLD
 SHEET SHALL BE INCLUDED WITH THE
 RESUBMITTAL FOR COMPARISON OF REVISIONS.
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 TELEPHONE: (561) 805 6716ROBERT BROWN
 E-MAIL: [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-22 Cont ID  
Sent By dpalmer Date 2003-07-22 Time 16:46 Rev Time 0.33
Received By dpalmer Date 2003-07-22 Time 16:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-07-23 Cont ID  
Sent By mcarsill Date 2003-07-23 Time 17:05 Rev Time 0.00
Received By mcarsill Date 2003-07-23 Time 17:05 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-09-08 Cont ID  
Sent By csiegber Date 2003-09-08 Time 12:07 Rev Time 0.00
Received By csiegber Date 2003-09-08 Time 12:07 Sent To P
Notes
2003-09-08 00:00:00TO KS BOX/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-26 Cont ID  
Sent By dbaxter Date 2003-08-26 Time 10:46 Rev Time 0.00
Received By dbaxter Date 2003-08-26 Time 10:46 Sent To B
Notes
2003-08-26 00:00:00TO RBROWN DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-07-17 Cont ID  
Sent By shernand Date 2003-07-17 Time 11:41 Rev Time 0.00
Received By shernand Date 2003-07-17 Time 11:41 Sent To  
Notes
2003-07-17 00:00:00COMM BOARD #29

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-26 Cont ID  
Sent By pkrauss Date 2003-07-26 Time 11:27 Rev Time 0.25
Received By pkrauss Date 2003-07-26 Time 11:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2003-09-16 Cont ID  
Sent By kstevens Date 2003-09-16 Time 12:08 Rev Time 0.50
Received By kstevens Date 2003-09-16 Time 12:30 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2003-08-28 Cont ID  
Sent By csiegber Date 2003-09-08 Time 12:07 Rev Time 0.50
Received By kstevens Date 2003-08-27 Time 18:47 Sent To  
Notes
2003-08-27 00:00:00DENIED
 REFERENCE: FBC-2001 PLUMBING
  
 1) SHT 2 MANUF. SPEC. SHEETS REQUIRED.
 PUMP SHALL BE LABELED PER SEC 303.4
 SHEETS SHALL SHOW LISTING BY APPROVED
 TESTING AGENCY.SECTION 303.4
 2) PUMP DISCHARGE LINE SHALL BE INSTALL-
 ED WITH A CHECK VALVE AND SHUT OFF
 VALVES ON DISCHARGE SIDE OF CHECK VALVE
 FOR SERVICE. SECTION 712.2
 3) PUMP TANK SHALL CONNECT INTO STANDARD
 VENT SYSTEM. SECTION 916.5.1
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692
 E-MAIL [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-08-27 Cont ID  
Sent By rbrown Date 2003-08-08 Time 14:55 Rev Time 0.00
Received By rbrown Date   Time   Sent To  
Notes
2003-08-08 00:00:00NO PLANS. SEPARATE PLUMBING PERMIT REQ'D