Plan Review Stops For Permit 03071132 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2004-05-11 |
|
|
Cont ID |
|
Sent By |
lsmith |
Date |
2004-05-11 |
Time |
13:13 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
2004-05-11 |
Time |
13:13 |
Sent To |
|
|
Notes |
2004-05-11 00:00:00 | SEE SHEETS A10 & A11 NOT REVISED. NEED | | PAPERWORK TO SAY SHELBY HOMES AS | | CONTRACTOR NOT DOUBLE R.NEED NEW A10&A11 | | SHEETS REVISION DATES 9/3 & 9/23/04. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-08-15 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
11:38 |
Rev Time |
0.50 |
Received By |
lsmith |
Date |
2003-08-15 |
Time |
08:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-15 |
Time |
08:31 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-08-08 00:00:00 | *****************BUILDING*************** | | | | 1. ACCORDING TO CITY AMEND. TO FBC | | 1804.2.2 A SOIL REPORT IS REQUIRED. | | | | 2. SUBMIT AN INSTALLATION SCHEDULE & KEY | | PLAN FOR THE STORM PANELS PRIOR TO | | INSTALLATION.SHOW ANCHOR TYPE, | | SPACING, TYPE OF MOUNT, CONNECTION | | TYPE, OPENING SIZE, PANEL SPAN, | | PRESSURES, ETC. | | | | 3. HI-LITE GLASS BLOCK ON THE PRODUCT | | APPROVAL SHOWING FIRE RATING (UL SHEET). | | | | 4.TAKE PLANS TO PALM BEACH COUNTY TO | | PAYIMPACT FEES.RESUBMIT PLANS STAMPED | | & A COPY OF THE PAID RECEIPT BEFORE A | | PERMIT CAN BE ISSUED. | | | | 5. FILE A NOTICE OF COMMENCEMENT & | | SUBMIT COPY BEFORE PERMIT ISSUED. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2004-08-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2004-08-30 |
Time |
07:14 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2004-08-30 |
Time |
07:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2004-08-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-24 |
Time |
10:06 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2004-08-03 |
Time |
14:00 |
Sent To |
|
|
Notes |
2004-08-03 00:00:00 | ****** UNSAT ************ | | | | 1 )NOTE: PLEASE LIST THE REQ'D ARC | | FAULT PROTECTED CURCUIT(S) ON PANEL | | SCHEDULE. PLEASE SEE THAT ALL "OUTLETS" | | IN BEDROOMS ARE TO BE PROTECTED , | | INCLUDING, LTS, RECEPTS, SD'S ETC. | | 2002 NEC 210.12B | | | | 2)NOTE: PLEASE SEE MISSING LICENSE #'S | | REQUIRED ON TITLE BLOCK. | | FAC 61G1-16.004, FS 481.219 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-29 |
Time |
08:27 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-28 |
Time |
11:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
10:38 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-10-06 |
Time |
12:47 |
Sent To |
|
|
Notes |
2003-10-06 00:00:00 | ************** UNSAT ************ | | | | 1)NOTE: PLEASE SEE FAC AND FS, 61G1-16. | | 002 AND 471. | | PLANS MISSING LICENSE INFORMATION REQ'D | | ON TITLE BLOCK. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2003-07-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:04 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-07-30 |
Time |
18:44 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2004-08-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-08-24 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-08-24 |
Time |
10:06 |
Sent To |
E |
|
Notes |
2004-08-24 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2004-07-29 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-07-29 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-07-29 |
Time |
08:27 |
Sent To |
E |
|
Notes |
2004-07-29 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2004-05-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2004-05-11 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2004-05-11 |
Time |
11:38 |
Sent To |
B |
|
Notes |
2004-05-11 00:00:00 | TO LS DESK/RESTAMP |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
10:38 |
Sent To |
E |
|
Notes |
2003-10-24 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:04 |
Sent To |
E |
|
Notes |
2003-10-02 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-08-15 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-15 |
Time |
08:31 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-15 |
Time |
08:31 |
Sent To |
B |
|
Notes |
2003-08-15 00:00:00 | TO LS DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-24 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-24 |
Time |
11:22 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-07-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-07-24 |
Time |
11:02 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-18 |
Time |
09:28 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-07-30 |
Time |
18:44 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-10 |
Time |
18:44 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-08-11 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-10 |
Time |
18:44 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-08-11 |
Time |
16:36 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-18 |
Time |
09:28 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|