Plan Review Stops For Permit 03071078 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2003-11-14 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2003-11-14 |
Time |
14:46 |
Rev Time |
2.00 |
Received By |
rmcdouga |
Date |
2003-11-14 |
Time |
14:46 |
Sent To |
|
|
Notes |
2003-11-14 00:00:00 | PROVISO | | | | SUBMIT SIGNED AND SEALED COPY OF THE | | SUBSURFACE SOIL TEST REPORT REQUIRED BY | | CITY AMENDMENTS TO FBC 1804.2.2, BEFORE | | THE FOUNDATION IS POURED. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2003-09-25 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2003-09-25 |
Time |
11:07 |
Rev Time |
2.50 |
Received By |
rmcdouga |
Date |
2003-09-25 |
Time |
11:07 |
Sent To |
|
|
Notes |
2003-09-25 00:00:00 | DENIED | | | | 1) FL BLD CODE 1804.2.2 QUESTIONABLE | | SOILS, WHERE THE BEARING CAPACITY IS | | NOT DEFINETLY KNOWN OR IS IN QUESTION. | | WHERE THE BEARING CAPACITY OF THE SOIL I | | S NOT DEFINITEY KNOWN, OR IS IN QUESTION | | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR | | ATIONS, TEST OR OTHER ADEQUATE PROOF AS | | TO THE PERMISSIBLE SAFE BEARING | | CAPACITY. REQUIRED TEST AND RECOMMENDA- | | TIONS SUBMITTED TO VERIFY BEARING CAPA- | | CITY SHALL BE CERTIFIED BY A GEOTECH- | | NICALREPORT FROM A DESIGN PROFESSIONAL P | | ROPERLY LICENSED IN THE STATE OF | | FLORIDA. PLEASE SUBMIT A SOIL BORING | | TEST REPORT. | | | | 2) BOTH FBC 1609.4.3 AND ASCE 7-98 2.4.3 | | DO NOT PERMIT INCREASES IN THE ALLOWABLE | | STRESS FOR THE STEEL FOR THE TRUSS | | CONNECTORS. THE EXCEPTIONS IN FBC | | 1609.4.3 ALLOW INCREASES TO BE TAKEN FOR | | MASONRY COMPONENTS (ACI530/ASCE5/TMS402) | | AND HURRICANE PANELS AND ASCE 7-98 2.4.3 | | ALLOWS IT ONLY IF THE INCREASE CAN BE | | JUSTIFIED BY STRUCTURAL BEHAVIOR CAUSED | | BY RATE OR DURATION OF LOAD. PLEASE | | REVISE THE TRUSS ANCHOR SCHEDULE ON G1 | | TO THE VALUES LISTED IN THE 2003 USP AND | | SIMPSON (HIGH WIND ADDITION) WHICH DO | | NOT INCLUDE A ONE-THIRD INCREASE ON THE | | STEEL CALCULATIONS. ALSO SPECIFY THE | | PROPER CONNECTOR STOCK OR MODEL NUMBER | | FOR THE NUMBER OF FASTENERS THAT ARE | | SPECIFIED. | | | | 3) SUBMIT A KEY PLAN AND INSTALLATION | | SCHEDULE FOR THE STORM PANELS. THE | | FOLLOWING INFORMATION IS REQUIRED: TYPE | | AND SPACING OF ANCHORS, MOUNT TYPE, | | CONNECTION TYPE, SHUTTER SPAN, AND | | OPENING PRESSURE. THIS INFORMATION IS | | REQUIRED FOR PLAN REVIEW OR A SEPARATE | | PERMIT WILL BE REQUIRED. | | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL: | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-09-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-08-14 |
Time |
17:32 |
Rev Time |
2.50 |
Received By |
rmcdouga |
Date |
2003-08-11 |
Time |
08:43 |
Sent To |
M |
|
Notes |
2003-08-08 00:00:00 | DENIED | | | | 1) SUBMIT COPY OF UNITY OF TITLE FOR THE | | TWO LOTS. | | | | 2) SUBMIT A SOIL BORING TEST REPORT AS | | REQUIRED BY CITY AMEND. TO FBC 1804.2.2. | | | | 3) THE A/C AREA LISTED ON A-3 OF THE | | PLANS DOES NOT CORRESPOND WITH THE | | CONDITIONED AREA ON THE ENERGY CALCS. OR | | THE COUNTY IMPACT FEE STAMP. PLEASE | | CORRECT. | | | | 4) SPECIFY ON THE PLANS THAT THE WIRE | | MESH IN THE SLAB IS REQUIRED TO BE | | SUPPORTED ON APPROVED MATERIALS AT NO | | MORE THAN 3FT. OC. PER FBC 1909.3. | | | | 5) SPECIFY THE SIZE OF THE SOFFIT VENTS | | ON A-6. SEE FBC 2309.7.1. | | | | 6) CONFLICTING DIMENSIONS ARE SPECIFIED | | FOR THE STEEL COLUMN CAP IN DETAIL 1 ON | | G2. PLEASE CORRECT. | | | | 7) TWO DETAILS ARE LABELED 1 ON G2. | | | | 8) FBC1609.4 NO LONGER ALLOWS THE ONE- | | THIRD STRESS INCREASE FOR STEEL CALCS. | | FOR COMBINATION LOADS. PLEASE REVISE | | THE ANCHOR SCHEDULE ON G1 TO VALUES THAT | | DO NOT INCLUDE THE INCREASE. SEE 2003 | | USP CATALOG. | | | | 9) THE ENGINEER'S LICENSE NUMBER OR | | CERTIFICATE OF AUTHORIZATION IS REQUIRED | | TO BE IN THE TITLE BLOCK. SEE 61G15- | | 23.002 | | | | 10) PROVIDE (2) CURRENT AND COMPLETE | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | APPROVALS FOR: | | - STRUCTURAL MULLIONS | | - ARCHED TOP FIXED GLASS WINDOWS | | | | 11) SUBMIT A KEY PLAN AND INSTALLATION | | SCHEDULE FOR THE STORM PANELS. THE | | SHUTTER PLAN ON A-3 DOES NOT LIST THE | | FRENCH DOORS OR THE SIDELITES AT THE | | ENTRY DOOR. THE FOLLOWING INFORMATION IS | | REQUIRED: TYPE OF ANCHORS, SPACING OF | | ANCHORS, TYPE OF MOUNT, CONNECTION TYPE, | | SHUTTER SPAN, AND OPENING PRESSURES. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2003-11-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-06 |
Time |
11:59 |
Rev Time |
0.75 |
Received By |
dpalmer |
Date |
2003-11-06 |
Time |
11:49 |
Sent To |
M |
|
Notes |
2003-11-06 00:00:00 | ********* NOTES REDLINED ******* | | | | 1)NOTE; PLEASE SEE CORRELATE LOAD/OCP | | AND AWG FOR AHU, SHOWS 8KW , 30A BRKR, | | AND #10 AWG?? 424.3B | | | | 2)NOTE: PLEASE SEE DISHWASHER, 30A BRKR | | AND #12 FOR A 20A LOAD.?? | | | | PLANS TO BE REVISED BEFORE ROUGH. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2003-09-11 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-03 |
Time |
16:08 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-09-11 |
Time |
07:15 |
Sent To |
P |
|
Notes |
2003-09-11 00:00:00 | *************** UNSAT *************** | | | | 1)NOTE: PLEASE SEE NOTES FROM REVIEW. | | PLEASE SEE THAT SOME NOTES WERE NOT | | ADRESSED. | | | | 2)NOTE: PLEASE SEE THAT SOME OCP DEVICES | | SHOWN ON PANEL SCHEDULE HAVE NOW BEEN | | CHANGED TO 2POLE BRKRS FOR SINGLE POLE | | ITEMS? | | | | 3)NOTE: PLEASE "LIST THE REQ'D ARC FAULT | | CIRCUITS ON PANEL SCHEDULES. 210.12 | | NOT OUTLETS,, CIRCUITS. | | 4)NOTE: PLEASE SEE THAT AIC RATING IS | | NOW SHOWN FOR FOR METER? NEEDS TO BE | | SHOWN FOR MAINS/ PANELS. 110.9/215.5 | | | | 5)NOTE: PLEASE SEE SERVICE AND NOTES | | FROM FIRST REVIEW. SERVICE IS STILL | | NOTED TO HAVE A 300A MAIN? BUTNONE | | SHOWN ON RISER OR PLANS.?? | | PLEASE SEE CONDCUTORS ETC . | | PLEASE SEE ORIG COMMENTS. | | 250.66/310.16/310.15/240ETC NEC | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | PLEASE SEE ATTACHED LETTER WITH RESPECT | | TO DESIGN PROFESSIONALS. REQ'D PER FS | | 553.80(2)(B). | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-07-30 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-09 |
Time |
10:38 |
Rev Time |
0.50 |
Received By |
dpalmer |
Date |
2003-07-30 |
Time |
17:50 |
Sent To |
M |
|
Notes |
2003-07-30 00:00:00 | *********** UNSAT **************** | | | | 1)NOTE: PLEASE SIZE GROUNDING ELECTRODE | | PER 250.66/ 310.15 #2 MIN | | | | 2)NOTE: RISER MENTIONS, 300 MAIN W/ OCP | | BUT SHOWS WHAT APPEARS TO BE A GUTTER? | | PLEASE CLARIFY HOW A 300A MAIN FEEDS TO | | TWO 150A PANELS? PLEASE | | | | 3)NOTE; PLEASE CORRELATE PLANS WITH | | RISER DIAGRAM. PLANS SHOW ONLY ONE PANEL | | AND NO MAIN? 215.5 | | | | 4)NOTE: PLEASE SHOW MISSING EQUIPMENT | | GROUNDING CONDUCTORS FROM MAIN TO PANELS | | 250.110/SIZE PER 250.122 | | | | 5)NOTE: PLEASE SUBMIT AIC RATING FOR | | 300A MAIN. 110.9 | | | | 6)NOTE: PLEASE CORRELATE OCPAND LOADS | | ON PANEL SCHEDULE. MICRO/ POOL PUMP/ | | WELL PUMP ETC, SHOWN AS 2P50 W/ #6 AND | | 1.5KW LOADS?? PLEASE ALSO SEE WASHER | | SHOWN AS 2P-50A? | | | | 7)NOTE: PLEASE SEE 20A OCP FOR #14 AWG | | GEN LT CIRCUITS. 240, 300 | | | | 8)NOTE: PLEASE LIST THE REQ`D ARC FAULT | | PROTECTED CIRCUITS ON PANEL SCHEDULE. | | 210.12 | | | | 9)NOTE: PLEASE LIST THE REQ`D DEDICATED' | | BATH(S) CIRCUIT(S).210.52D, 210.11C.3 | | | | 10)NOTE: PLEASE SHOW GARAGERECEPT | | AS GFI/GFI PROTECTED PER 210.8 | | | | 11)NOTE: PLEASE SEE MISSING SD IN DEN | | THIS RM IS AN ADAPTABLE SLEEPING RM AND | | REQUIRE'S A SD INSIDE AND OUTSIDE | | NFPA-72 8-1.4.2 | | | | 12)NOTE: PLEASE SEE MISSING RECEPTS PER | | 210.52 | | | | 13)NOTE: PLEASE SEE THAT ALL RECEPTS IN | | BATHS TO BE W/IN 3' OF SINKS. | | 210-52D | | | | 14)NOTE: PLEASE SEE LETTER ATTACHED FOR | | MISSING INFORMATION REQ`D ON TITLE | | BLOCK FOR ENGINEER OF RECORD. | | FS 471/ FAC 61G15-23.002 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW.IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-11-03 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-03 |
Time |
16:08 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-03 |
Time |
16:08 |
Sent To |
E |
|
Notes |
2003-11-03 00:00:00 | TO DP DESK/2ND RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-09-09 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-09-09 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-09-09 |
Time |
10:37 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-24 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-24 |
Time |
12:59 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-07-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-07-24 |
Time |
10:08 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-16 |
Time |
10:29 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2004-08-05 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2004-08-05 |
Time |
16:40 |
Rev Time |
0.30 |
Received By |
pkrauss |
Date |
2004-08-05 |
Time |
16:40 |
Sent To |
|
|
Notes |
2004-08-05 00:00:00 | SUBMITAL ON THE AC 1.5 TON CARRIER 12 | | SEER.PER CARRIER, THEY DO NOT MAKE A | | 1.5 TON 12 SEER UNIT.STRUCTURAL | | ENGINEER SUBMITTED PLANS WITH EQUIPMENT | | SCHEDULE (INCORRECT).PLANS SUBMITTED | | WITH CARRIER SUBMITTAL FOR PROPER | | A/C WITH PROPER SEER. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561) 805-6719. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-08-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-11-06 |
Time |
11:59 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-12 |
Time |
06:23 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-09-24 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-09-24 |
Time |
19:01 |
Rev Time |
0.33 |
Received By |
jleech |
Date |
2003-09-24 |
Time |
19:01 |
Sent To |
|
|
Notes |
2003-09-24 00:00:00 | RESTAMP |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2003-08-14 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-09-11 |
Time |
07:16 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-08-14 |
Time |
17:31 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-07-24 |
Time |
10:08 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2003-07-21 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-16 |
Time |
10:29 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2003-07-21 00:00:00 | 7/21/03 DENIED, NEED SURVEY CALLED CONTR | | FILE G MM |
|
|