Plan Review Stops For Permit 03070892 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-07-24 |
Time |
09:41 |
Rev Time |
1.00 |
Received By |
jwitmer |
Date |
2003-07-24 |
Time |
09:41 |
Sent To |
|
|
Notes |
2003-07-24 00:00:00 | MASTER PLAN 02080923 MODEL "B" | | 1609.4.3 LOAD REDUCTION. | | WHEN STRUCTURAL EFFECTS DUE TO TWO OR | | MORE LOADS IN COMBINATION WITH DEAD LOAD | | ARE INVESTIGATED IN LOAD COMBINATIONS OF | | 1609.4.1 OR 1609.4.2, THE COMBINED | | EFFECTS DUE TO THE TWO OR LOADS MULTI- | | PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD | | LOADS SHALL NOT BE LESS THAN THE EFFECTS | | FROM THE LOAD COMBINATION OF THE DEAD | | LOAD PLUS THE LOAD PRODUCING THE LARGEST | | EFFECTS. INCREAS IN ALLOWABLE STRESS SPE | | CIFIED IN THE MATERIALS SECTIONS OF THIS | | CODE OR A REFRENCED STANDARD SHALL NOT | | BE USED WITH THESE LOAD COMBINATIONS | | EXCEPT THAT A DURATION OF LOAD INCREASE | | SHALL BE PERMITTED IN ACCORDANCE WITH | | CHAPTER 23. | | | | RE-EVALUATE TRUSS ANCHOR SCHEDULE BEFORE | | FOOR FRAMING INSPECTION. | | JIM WITMER | | (561)805-6715 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-07-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-23 |
Time |
10:57 |
Rev Time |
0.50 |
Received By |
jwitmer |
Date |
2003-07-17 |
Time |
06:27 |
Sent To |
|
|
Notes |
2003-07-17 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 03070892 | | ADD: 3462 BOLLARD ROAD | | CONT: HOME DYNAMICS | | TEL: (954)520-1698 | | FL BLD CODE= 2001 FLORIDA BUILDING CODE | | | | ACTION: DENIED | | | | 1) MASTER PLAN: NO CHANGE CAN TAKE PLACE | | TO A MASTER PLAN, SEE "WHITE OUT"!!!!!!! | | | | 2) PLANS, SPECIFICATIONS,REPORTS OR | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | RECORD SHALL HAVE THE SIGNATURE AND | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | TO THE DOCUMENT. | | FL STATE STAT: 61G15-23.002 ENGINEERS | | FL ATATE STAT: 61G16.003 ARCHITECTS | | KNEZEVICH SITE SPECIFIC FORM NOT SEALED! | | | | 3) MULLION REPORT EXPIRED!!!!!!!! | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-07-17 |
Time |
06:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-07-17 |
Time |
06:27 |
Sent To |
|
|
Notes |
2003-07-17 00:00:00 | MASTER PLAN 02080923 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-11-14 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-11-14 |
Time |
14:28 |
Sent To |
M |
|
Notes |
2003-11-14 00:00:00 | TO PK DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-07-23 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-07-23 |
Time |
10:57 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-07-23 |
Time |
10:57 |
Sent To |
B |
|
Notes |
2003-07-23 00:00:00 | TO JW DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-07-14 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-14 |
Time |
10:09 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-07-14 |
Time |
10:09 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-11-18 |
|
|
Cont ID |
|
Sent By |
rregueir |
Date |
2003-11-18 |
Time |
17:25 |
Rev Time |
0.25 |
Received By |
rregueir |
Date |
2003-11-18 |
Time |
17:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-11-14 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-07-17 |
Time |
06:27 |
Sent To |
|
|
Notes |
2003-07-17 00:00:00 | MASTER PLAN 02080923 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2003-07-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2003-07-17 |
Time |
06:27 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2003-07-17 |
Time |
06:27 |
Sent To |
|
|
Notes |
2003-07-17 00:00:00 | MASTER PLAN 02080923 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-07-15 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-07-14 |
Time |
10:09 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
B |
|
Notes |
2003-07-15 00:00:00 | 7/15/03 GIVEN TO JIM WITMER MM |
|
|