Plan Review Stops For Permit 03062025 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-08-18 |
Time |
07:56 |
Rev Time |
1.00 |
Received By |
lsmith |
Date |
2003-08-18 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2003-07-24 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2003-07-14 |
Time |
15:41 |
Rev Time |
2.00 |
Received By |
lsmith |
Date |
2003-07-24 |
Time |
08:33 |
Sent To |
|
|
Notes |
2003-07-24 00:00:00 | *****************FAILED**************** | | | | 1. PLANS MUST BE TAKEN TO PBC FOR | | PAYMENT OF IMPACT FEES.A RECEIPT & | | STAMPED PLANS TO BE RETURNED TO WPB | | CONSTRUCTION SERVICES BEFORE A PERMIT | | CAN BE ISSUED. | | | | 2. A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED AT TIME | | OF PERMITING. | | | | 3. A SOIL BORING TEST REPORT IS REQUIRED | | BY CITY AMENDMENT TO FBC 1804.2.2. | | | | 4. THE MECHANICAL DRAWING SUBMITTED | | SHOWS THE GARAGE LEFT.THE FLOOR PLANS | | SHOWS GARAGE RIGHT.PLEASE CORRECT. | | | | | | ANY QUESTIONS PLEASE CALL: | | LEA SMITH, BUILDING PLANS EXAMINER | | 805-6713 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2003-10-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-10-28 |
Time |
11:57 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-10-28 |
Time |
11:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2003-10-06 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
12:39 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-10-06 |
Time |
09:22 |
Sent To |
|
|
Notes |
2003-10-06 00:00:00 | ********** UNSAT ******************** | | | | 1)NOTE: PLEASE SEE MISSING INFORMATION | | REQ'D ON TITLE BLOCK FOR ARCH'S. FAC | | 61G1-16.004/ FS 481 | | | | 2)NOTE: PLEASE NOTE, SERVICE IS NOW | | CHANGED TO A METER/MAIN COMBO, BUT IS | | STILL SHOWING A MCB. THIS IS JUST A NOTE | | , MCB IS PERMITTED , HOWEVER IT IS NOT | | REQ'D. IF SHOWN ON PLAN, THEN THIS MUST | | BE INSTALLED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2003-08-08 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:03 |
Rev Time |
0.33 |
Received By |
dpalmer |
Date |
2003-08-08 |
Time |
06:26 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2003-07-08 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
14:50 |
Rev Time |
0.25 |
Received By |
dpalmer |
Date |
2003-07-08 |
Time |
06:56 |
Sent To |
P |
|
Notes |
2003-07-08 00:00:00 | ************ UNSAT **************** | | | | 1)NOTE; PLEASE SEE MISSING LICENSE/FIRM | | # ON TITLE BLOCK AS REQ`D UNDER FAC/FS | | 61G1-16.004. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2003-10-24 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-24 |
Time |
12:39 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-24 |
Time |
12:39 |
Sent To |
E |
|
Notes |
2003-10-24 00:00:00 | TO DP DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2003-10-02 |
|
|
Cont ID |
|
Sent By |
csiegber |
Date |
2003-10-02 |
Time |
11:03 |
Rev Time |
0.00 |
Received By |
csiegber |
Date |
2003-10-02 |
Time |
11:03 |
Sent To |
E |
|
Notes |
2003-10-02 00:00:00 | TO DP/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2003-08-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2003-08-06 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2003-08-06 |
Time |
14:49 |
Sent To |
E |
|
Notes |
2003-08-06 00:00:00 | TO DP DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2003-06-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2003-07-02 |
Time |
11:49 |
Rev Time |
0.00 |
Received By |
shernand |
Date |
2003-06-30 |
Time |
09:45 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2003-08-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-08-15 |
Time |
08:46 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-08-18 |
Time |
07:55 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2003-07-14 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2003-07-10 |
Time |
19:58 |
Rev Time |
0.25 |
Received By |
pkrauss |
Date |
2003-07-14 |
Time |
15:40 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2003-08-15 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2003-08-15 |
Time |
08:46 |
Rev Time |
0.33 |
Received By |
kstevens |
Date |
2003-08-15 |
Time |
08:46 |
Sent To |
M |
|
Notes |
2003-08-15 00:00:00 | PASSED/PROVISO - REVISION REQUIRED. | | LAVS NOT ON COMMON WALLS, TEE NOT APPRO- | | VED, 909.1 W/M L/T SHALL NOT DRAIN INTO | | WET VENTED BRANCH LINE. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2003-07-10 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2003-08-08 |
Time |
06:30 |
Rev Time |
0.25 |
Received By |
jleech |
Date |
2003-07-10 |
Time |
19:58 |
Sent To |
M |
|
Notes |
2003-07-10 00:00:00 | TITLE BLOCK MISSING LICENSE NUMBER. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2003-07-02 |
|
|
Cont ID |
|
Sent By |
shernand |
Date |
2003-06-30 |
Time |
09:45 |
Rev Time |
1.00 |
Received By |
mmclean |
Date |
|
Time |
|
Sent To |
I |
|
Notes |
|
|