Plan Review Details - Permit 03061772
Plan Review Stops For Permit 03061772
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2003-08-08 Cont ID  
Sent By jwitmer Date 2003-08-08 Time 11:52 Rev Time 1.50
Received By jwitmer Date 2003-08-08 Time 11:52 Sent To  
Notes
2003-08-08 00:00:00 
 *** ISSUED PERMIT***
 -PLAN REVIEW HISTORY-
  
 PERMIT# 03061772
 ADDRESS: 8465 PINE CAY
 CONT: TAZ CONSTRUCTION
 TELL # (954)340-1744
  
 THE ATTACHED COMMENTS ARE PART OF THE
 PERMIT AND PLAN REVIEW PACKAGE AND ARE
 NOT TO BE REMOVED FROM THE ISSUED SET OF
 PLANS.104.2.1.2 ADMINISTRATIVE CODE.
  
 *****BUILDING PROVISO*****
  
 PROVIDE FLOOD ZONE ELEVATION
 CERTIFICATE FOR NEW CONSTRUTION WITH
 BASE FLOOD ELEVATION, CITY CODE REQUIRES
 AN ADDITIONAL 6".BEFORE C.O.
  
 CONTRACTOR AONTINUING AT OWN RISK,
 A PRELIMINARY SOILS REPORT SUBMITTED
 NOT SIGNED/NOR SEALED. LIMITATIONS(5.0)
 IT IS IMPORTANT TO REALIZE THAT THE
 INFORMATION PROVIDED IN THIS REPORT IS
 NOT SUFFICIENT FOR A FINAL DESIGN OF THE
 FOUNDATION SYSTEM.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-29 Cont ID  
Sent By alange Date 2003-08-07 Time 14:45 Rev Time 2.50
Received By jwitmer Date 2003-07-29 Time 07:48 Sent To  
Notes
2003-07-29 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03061772
 ADD: 8465 PINE CAY
 CONT: TAZ
 TEL: (954)340-1744
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 ACTION: DENIED
  
 1)1609.4.3 LOAD REDUCTION.TRUSS ANCHORS,
 WHEN STRUCTURAL EFFECTS DUE TO TWO OR
 MORE LOADS IN COMBINATION WITH DEAD LOAD
 ARE INVESTIGATED IN LOAD COMBINATIONS OF
 1609.4.1 OR 1609.4.2, THE COMBINED
 EFFECTS DUE TO THE TWO OR LOADS MULTI-
 PLIED BY 0.75 PLUS EFFECTS DUE TO DEAD
 LOADS SHALL NOT BE LESS THAN THE EFFECTS
 FROM THE LOAD COMBINATION OF THE DEAD
 LOAD PLUS THE LOAD PRODUCING THE LARGEST
 EFFECTS. INCREAS IN ALLOWABLE STRESS SPE
 CIFIED IN THE MATERIALS SECTIONS OF THIS
 CODE OR A REFRENCED STANDARD SHALL NOT
 BE USED WITH THESE LOAD COMBINATIONS
 EXCEPT THAT A DURATION OF LOAD INCREASE
 SHALL BE PERMITTED IN ACCORDANCE WITH
 CHAPTER 23.
 RE-EVALUATE TRUSS ANCHOR SCHEDULE,
 DETAIL 15 ON SHEET A-5 INDICATE THE
 USE OF A SINGLE MEMBER TRUSS WITH A MAX.
 UPLIFT OF 3833, THE TWO TA14R + THE MSH2
 18 COMBINED ARE ONLY GOOD FOR 3560.
  
 DETAIL 14 THE COMBINED ALLOWABLE UPLIFT
 FOR A SINGLE MEMBER UNIT IS 2845, THE
 PLANS INDICATE 3215.
  
 DETAIL 8 THE VALUES HAVE NOT BEEN DE-
 CREASED TO ALIGN THEMSELVES WITH THE
 FL CODE. RE-EVALUATE.1609.4.3
  
 SHEET A-6 TRUSS CONNECTOR SCHEDULE,
 RE-EVALUATE TO ALIGN WITH FL. BLDG. CODE
 1609.4.3.
  
 2) FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORT, SBCCI OR DADE COUNTY
 REPORT ARE ACCEPTED. MISSING REPORTS:
 A) FRONT DOOR
 B) ROOFING ASSEMBLIES
  
 3) CONTRACTOR CONTINUING AT OWN RISK,
 NO SEALED COPY OF SOILS REPORT, ONLY A
 COPY OF THE PRELIMINARY REPORT HAS BEEN
 SUBMITTED.PAGE 9 OF 9,"IT IS IMPORTANT
 TO REALIZE THAT THE INFORMATION PROVIDED
 IN THIS REPORT IS NOT SUFFICIENT FOR A
 FINAL DESIGN OF THE FOUNDATION SYSTEM."
  
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2004-02-23 Cont ID  
Sent By dpalmer Date 2004-02-23 Time 12:36 Rev Time 0.33
Received By dpalmer Date 2004-02-23 Time 12:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-14 Cont ID  
Sent By dpalmer Date 2003-07-14 Time 16:33 Rev Time 0.33
Received By dpalmer Date 2003-07-14 Time 16:33 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-08-07 Cont ID  
Sent By alange Date 2003-08-07 Time 14:45 Rev Time 0.00
Received By alange Date 2003-08-07 Time 14:45 Sent To B
Notes
2003-08-07 00:00:00TO JW DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-30 Cont ID  
Sent By mmclean Date 2003-07-03 Time 11:01 Rev Time 0.00
Received By shernand Date 2003-06-30 Time 16:45 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-15 Cont ID  
Sent By jleech Date 2003-07-15 Time 17:46 Rev Time 0.25
Received By hmoser Date 2003-07-15 Time 18:41 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-07-15 Cont ID  
Sent By dpalmer Date 2003-07-14 Time 16:34 Rev Time 0.25
Received By jleech Date 2003-07-15 Time 17:45 Sent To M
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2003-07-03 Cont ID  
Sent By shernand Date 2003-06-30 Time 16:45 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***