Plan Review Details - Permit 03061712
Plan Review Stops For Permit 03061712
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2004-01-30 Cont ID  
Sent By btrobaug Date 2004-01-28 Time 18:07 Rev Time 0.50
Received By shill Date 2004-01-30 Time 16:30 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-03 Cont ID  
Sent By btrobaug Date 2004-01-28 Time 15:56 Rev Time 0.50
Received By sthyng Date 2003-07-03 Time 18:37 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2004-06-11 Cont ID  
Sent By btrobaug Date 2004-06-11 Time 16:26 Rev Time 0.33
Received By btrobaug Date 2004-06-11 Time 16:19 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2004-02-17 Cont ID  
Sent By csiegber Date 2004-06-11 Time 15:57 Rev Time 0.33
Received By btrobaug Date 2004-02-17 Time 13:14 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2004-01-28 Cont ID  
Sent By csiegber Date 2004-02-13 Time 16:30 Rev Time 0.33
Received By btrobaug Date 2004-01-28 Time 15:30 Sent To B
Notes
2004-01-28 00:00:00PLEASE PROVIDE A CALCULATION
 INCLUDING ALL ADDED LOADS IMPOSED,ALL
 EXISTING LOADS AND THE EXISTING OR
 PROPOSED SERVICE SPECIFICATIONS PER
 215.15.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
 FAX/:561/659-8026

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-01 Cont ID  
Sent By kstevens Date 2004-01-28 Time 09:39 Rev Time 0.33
Received By btrobaug Date 2003-07-01 Time 17:49 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2004-06-11 Cont ID  
Sent By csiegber Date 2004-06-11 Time 15:56 Rev Time 0.00
Received By csiegber Date 2004-06-11 Time 15:56 Sent To E
Notes
2004-06-11 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2004-02-13 Cont ID  
Sent By csiegber Date 2004-02-13 Time 16:28 Rev Time 0.00
Received By csiegber Date 2004-02-13 Time 16:28 Sent To E
Notes
2004-02-13 00:00:00TO BT DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2004-01-23 Cont ID  
Sent By csiegber Date 2004-01-23 Time 14:01 Rev Time 0.00
Received By csiegber Date 2004-01-23 Time 14:01 Sent To Z
Notes
2004-01-23 00:00:00REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-07-15 Cont ID  
Sent By shernand Date 2003-07-15 Time 09:25 Rev Time 0.00
Received By shernand Date 2003-07-15 Time 09:25 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-24 Cont ID  
Sent By shernand Date 2003-06-24 Time 16:31 Rev Time 0.00
Received By shernand Date 2003-06-24 Time 16:31 Sent To Z
Notes
***NONE***

Review Stop P PLUMBING
Rev No 4 Status P Date 2004-06-20 Cont ID  
Sent By pschmitz Date 2004-06-20 Time 13:52 Rev Time 0.60
Received By pschmitz Date   Time   Sent To  
Notes
2004-06-20 00:00:00PLAN REVIEW
 REVISION: DELETE HEAT PUMP.

Review Stop P PLUMBING
Rev No 3 Status P Date 2004-01-28 Cont ID  
Sent By btrobaug Date 2004-06-11 Time 16:26 Rev Time 0.50
Received By kstevens Date 2004-01-28 Time 09:39 Sent To E
Notes
2004-01-28 00:00:00REVISION OK - CHANGED POOL SHAPE - ADD
 SPA - ADD HEAT PUMP - INCREASE PUMP SIZE
 - ADD LION HEADS

Review Stop P PLUMBING
Rev No 2 Status P Date 2003-07-18 Cont ID  
Sent By kstevens Date 2003-07-18 Time 17:30 Rev Time 0.50
Received By kstevens Date 2003-07-18 Time 17:30 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2003-06-30 Cont ID  
Sent By shernand Date 2003-07-15 Time 09:25 Rev Time 0.50
Received By kstevens Date 2003-06-30 Time 06:12 Sent To E
Notes
2003-06-30 00:00:00DENIED
 REFERENCE: FBC-2001 424.2 SWIMMING POOLS
  
 A) PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING IN-
 FORMATION REQUIRED FOR PLAN REVIEW
 1) COMPLY WITH FBC-2001 SEC 424.2
 PRIVATE SWIMMING POOLS.
 2) FBC-2001 SEC 424.2.6.1 ENGINEERING
 DESIGN, CONSTRUCTION AND WORKMANSHIP.
 ANSI/NSPI-4 92, AND NSPI-5. (ADD TO
 NOTES)
 3) FBC-2001 424.2.9 WATER SUPPLY, LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE. (ADD TO NOTES)
 4) FBC-2001 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2001 424.2.13.2JOINTS AND CON-
 NECTIONS, FBC PLMG SEC 605.21, PURPLE
 PRIMER REQUIRED ON PVC PIPING. (ADD TO
 NOTES)
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 653-2692

Review Stop Z ZONING
Rev No 1 Status P Date 2003-06-30 Cont ID  
Sent By csiegber Date 2004-01-23 Time 14:01 Rev Time 1.00
Received By mmclean Date   Time   Sent To P
Notes
***NONE***