Plan Review Details - Permit 03061711
Plan Review Stops For Permit 03061711
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2003-07-05 Cont ID  
Sent By jwitmer Date 2003-07-05 Time 14:47 Rev Time 0.75
Received By jwitmer Date 2003-07-05 Time 14:47 Sent To  
Notes
2003-07-05 00:00:00BUILDING PLAN REVIEW
 PERMIT: 03061711
 ADD: 622 N FLAGLER DR. SUITE 1003
 CONT: FIRST CONSTRUCTION
 TEL: (561)687-2388
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
  
 *****PROVISO*****
  
 1) USABLE DOORS- DOORS THAT ALLOW PASS-
 AGE WITHIN THE DWELLING UNIT. USABLE
 DOORS ARE TO HAVE NOMINAL 32" CLEAR.
 A TOLERANCE OF 1/4" TO 3/8" ARE CONSIDER
 ED AN ACCEPTABLE RANGE FOR USABLE DOORS.
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 805-6715

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2003-09-22 Cont ID  
Sent By dpalmer Date 2003-09-22 Time 18:06 Rev Time 0.33
Received By dpalmer Date 2003-09-22 Time 18:06 Sent To  
Notes
2003-09-22 00:00:00REV'S FOR GEN LT/RECEPTS./ LV LTS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-07 Cont ID  
Sent By dpalmer Date 2003-07-07 Time 09:14 Rev Time 0.33
Received By dpalmer Date 2003-07-07 Time 09:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2003-09-25 Cont ID  
Sent By nmccray Date 2003-09-25 Time 11:19 Rev Time 0.00
Received By nmccray Date 2003-09-25 Time 11:16 Sent To  
Notes
2003-09-25 00:00:00REVISION DATED
 REVISION DATED 9-08-03

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2003-07-15 Cont ID  
Sent By nmccray Date 2003-07-15 Time 14:38 Rev Time 0.00
Received By nmccray Date 2003-07-15 Time 14:38 Sent To  
Notes
2003-07-15 00:00:00**************PROVISO*******************
 SEPARATE SHOP DRAWING AND PERMIT
 APPPLICATION ARE REQUIRED FOR FIRE
 SPRINKLER SYSTEM REMODEL BY LICENSE FIRE
 SPRINKLER CONTRACTOR.
  
  
 NATE MCCRAY, CAPTAIN
 805-6722 OR 835-2910

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-09-08 Cont ID  
Sent By csiegber Date 2003-09-08 Time 15:44 Rev Time 0.00
Received By csiegber Date 2003-09-08 Time 15:44 Sent To  
Notes
2003-09-08 00:00:00TO COMM BD#61

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-24 Cont ID  
Sent By shernand Date 2003-06-24 Time 13:22 Rev Time 0.00
Received By shernand Date 2003-06-24 Time 13:22 Sent To  
Notes
2003-06-24 00:00:00COMM BOARD #17

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-10-02 Cont ID  
Sent By pkrauss Date 2003-10-02 Time 09:12 Rev Time 0.15
Received By pkrauss Date 2003-10-02 Time 09:12 Sent To  
Notes
2003-10-02 00:00:00ADDED SUPPLY DROP TO WALK-IN CLOSET
 30 CFM.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2003-07-07 Cont ID  
Sent By pkrauss Date 2003-07-07 Time 11:51 Rev Time 0.25
Received By pkrauss Date 2003-07-07 Time 11:49 Sent To  
Notes
2003-07-07 00:00:00SUITE 1003 -
 RELOCATING 1 SUPPLY DUCT AND ROTATE
 1 RETURN DIFFUSER.PLEASE NOTE, RETURN
 IS ABOVE CEILING PLENUM.

Review Stop P PLUMBING
Rev No 2 Status N Date 2003-10-02 Cont ID  
Sent By kstevens Date 2003-10-02 Time 15:55 Rev Time 0.50
Received By kstevens Date 2003-10-02 Time 15:55 Sent To  
Notes
2003-10-02 00:00:00NO PLUMBING PLANS CHANGED/REVISIED

Review Stop P PLUMBING
Rev No 1 Status P Date 2003-06-27 Cont ID  
Sent By kstevens Date 2003-06-27 Time 12:06 Rev Time 0.50
Received By kstevens Date 2003-06-27 Time 12:05 Sent To  
Notes
2003-06-27 00:00:00LARGER SHOWER - DRAIN NOT MOVING.