Plan Review Details - Permit 03061645
Plan Review Stops For Permit 03061645
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2003-08-22 Cont ID  
Sent By sthyng Date 2003-08-21 Time 15:05 Rev Time 1.00
Received By sthyng Date 2003-08-21 Time 15:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2003-08-22 Cont ID  
Sent By sthyng Date 2003-08-18 Time 12:00 Rev Time 1.00
Received By sthyng Date 2003-08-18 Time 12:00 Sent To  
Notes
2003-08-18 00:00:00IMPACT FEES, PAS, EN CALC

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2003-07-17 Cont ID  
Sent By pkrauss Date 2003-08-15 Time 13:32 Rev Time 2.50
Received By sthyng Date 2003-07-17 Time 12:47 Sent To  
Notes
2003-07-17 00:00:00******CORRECTIONS******
  
 SAMANTHA THYNG, BUILDING PLANS EXAMINER
 [email protected]
  
 1.)THE PLANS SHOW A FIREPLACE. INCLUDE
 THIS IN THE PROJECT DESCRIPTION OF YOUR
 PERMIT APPLICATION.
  
 2.)ENGINEER TITLE BLOCK REQUIRED,
 FAC61G15-23.002.
  
 3.)THE SQUARE FOOTAGE OF LIVING SPACE
 IS BEING INCREASED (BETWEEN LIVING ROOM
 TO NEW CARPORT, FIREPLACE).THIS IS
 NOT REFLECTED ON THE IMPACT FEE STAMP.
  
 4.)PROVIDE AREA CALCULATIONS -
 EXISTING CONDITIONED AND UNCONDITIONED
 SPACE, PROPOSED, SUBTOTALS, NEW TOTAL.
  
 5.)ENERGY CALCS REQUIRED FBC13-101.2.
  
 6.)SOFFIT VENTS CANNOT "MATCH
 EXISTING", THEY MUST COMPLY WITH
 FBC2309.7.
  
 7.)ON THE WALL SECTION, SHOW THE
 MINIMUM DIMENSIONS ABOVE AND BELOW
 GRADE FOR THE FOUNDATION, FBC1804.1.3,
 CITY OF WPB AMENDMENTS TO THE FBC
 1804.1.7.
  
 8.)PROVIDE A ROOF SHEATHING NAILING
 SCHEDULE, CITY OF WPB AMENDMENTS TO
 THE FBC TABLE 2306.1.
  
 9.)IS THE PROPOSED DRIVEWAY SHOWN ON
 THE SITE PLAN TO BE ON THIS PERMIT? IF
 IT IS, ADD IT TO YOUR APPLICATION.THE
 SITE PLAN AND SURVEY CONFLICT AS TO
 THE DRIVEWAY CONFIGURATION.
  
 10.) THE SITE PLAN SUBMITTED FOR
 ZONING SHOWS ONLY A CARPORT.THE SITE
 PLAN SHOULD SHOW ALL IMPROVEMENTS -
 CARPORT, PORCH, LIVING AREA.REVISE.
  
 11.)SUBMIT TWO COPIES OF THE
 FOLLOWING PRODUCT APPROVALS:
 SHINGLES
 DOORS
 TRANSOM WINDOWS
 IMPACT PROTECTION FOR GLAZING
  
 12.)SHOW THE MINIMUM DIMENSIONS ABOVE
 THE ROOF FOR THE CHIMNEY, FBC2804.2.4.
  
 13.)PROVIDE INFORMATION FOR THE
 FACTORY BUILT FIREPLACE AND CHIMNEY.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2003-07-09 Cont ID  
Sent By dpalmer Date 2003-07-03 Time 15:44 Rev Time 0.25
Received By dpalmer Date 2003-07-09 Time 11:41 Sent To P
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2003-08-13 Cont ID  
Sent By sthyng Date 2003-08-13 Time 12:54 Rev Time 0.00
Received By sthyng Date 2003-08-13 Time 12:54 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2003-08-13 Cont ID  
Sent By dbaxter Date 2003-08-13 Time 11:25 Rev Time 0.00
Received By dbaxter Date 2003-08-13 Time 11:25 Sent To B
Notes
2003-08-13 00:00:00TO STHYNG DESK

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2003-08-08 Cont ID  
Sent By alange Date 2003-08-08 Time 09:42 Rev Time 0.00
Received By alange Date 2003-08-08 Time 09:42 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2003-07-03 Cont ID  
Sent By dpalmer Date 2003-07-03 Time 15:44 Rev Time 0.00
Received By dpalmer Date 2003-07-03 Time 15:44 Sent To E
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2003-06-30 Cont ID  
Sent By mmclean Date 2003-07-02 Time 16:50 Rev Time 0.00
Received By shernand Date 2003-06-30 Time 09:52 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2003-06-23 Cont ID  
Sent By shernand Date 2003-06-23 Time 15:09 Rev Time 0.00
Received By shernand Date 2003-06-23 Time 15:08 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2003-08-15 Cont ID  
Sent By pkrauss Date 2003-08-15 Time 13:32 Rev Time 0.25
Received By pkrauss Date 2003-08-15 Time 13:29 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2003-07-14 Cont ID  
Sent By sthyng Date 2003-08-13 Time 12:54 Rev Time 0.20
Received By pkrauss Date 2003-07-14 Time 07:16 Sent To B
Notes
2003-07-14 00:00:00DENIED:
  
 PLEASE PROVIDE SUBMITTAL DATA AND
 INSTALLATION INSTRUCTIONS FOR THE PRE-
 FAB FIREPLACE THAT IS INDICATED ON PLAN
 SHEET 2.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT (561) 805-6719.

Review Stop P PLUMBING
Rev No 1 Status N Date 2003-07-10 Cont ID  
Sent By dpalmer Date 2003-07-09 Time 11:46 Rev Time 0.25
Received By kstevens Date 2003-07-10 Time 14:33 Sent To M
Notes
2003-07-10 00:00:00ONLY RELOCATING THE WATER HEATER

Review Stop Z ZONING
Rev No 2 Status P Date 2003-07-02 Cont ID  
Sent By mmclean Date 2003-07-02 Time 16:50 Rev Time 1.00
Received By mmclean Date   Time   Sent To I
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2003-06-24 Cont ID  
Sent By shernand Date 2003-06-30 Time 09:52 Rev Time 1.00
Received By mmclean Date   Time   Sent To  
Notes
2003-06-24 00:00:006/24/03 DENIED, NEED TO BE 12 1/2FT
 CONTR CALL TO MAKE ADJUSTMENT & INITIAL
 MM